Tsarin Gano Laifin Kebul GD-2136H
GD2136H Cable Fault tsarin shine kayan aiki mai mahimmanci don kula da kowane nau'in igiyoyi.Yana amfani da hanyoyi daban-daban na ganowa don gwada kurakuran na USB, wanda ya dace da matakan ƙarfin lantarki daban-daban da igiyoyin sadarwa.
Tsarin ya ƙunshi raka'a a ƙasa:
1. GD-2131H Mai Haɓakawa
2. GD-2132 Cable Fault Locator
3. GD-2133 Cable Laifin Gwajin
4. Sauran kayan haɗi
Saukewa: GD-2131H
Ana amfani da shi don haifar da motsin HV lokacin amfani da hanyar walƙiya mai ƙarfi don gano kuskuren impedance.
●Ƙarfin ƙonawa mai ƙarfi, ƙarfin max.ƙonawa shine 1000W, za'a iya ƙone ma'aunin raguwa a cikin ɗan gajeren lokaci kuma an rage juriya na raguwa.
●Idan aiki tare da GD-2133 Cable Fault Tester, akwai hanyoyi guda biyu:
a.Low ƙarfin bugun bugun jini: Idan kawai ta amfani da GD-2133, bude kewaye da ƙananan impedance grounding kurakuran na USB za a iya located, da kuma tsawon na USB za a iya auna ko kalaman gudun na USB za a iya gano.
b.Babban walƙiya mai walƙiya: Ana yin samfur ɗin nau'in nau'in ƙarfin ƙarfin bugun bugun bugun jini na kuskure ta hanyar fitar da tazara, wanda zai iya gano tazarar kuskure.
●Ƙirƙirar motsawar ƙayyadaddun mitoci.Idan aiki tare da GD-2132 Cable Fault Locator, akwai ayyuka masu zuwa:
a.Ana amfani da hanyar mai jiwuwa don kammala madaidaicin wurin babban juriya na gabaɗaya da wuraren kuskuren walƙiya.
b.Don nuna hanyar kebul, gano kebul na musamman.
c.Don rushewar ƙarfe (mataccen ƙasa), ta amfani da ma'aunin filin maganadisu don gano daidai.
●Hakanan ana iya amfani dashi a gwajin jurewar DC HV.
●Mai shigar da wutar lantarki: AC 220V,50Hz
●Wutar lantarki mai fitarwa: DC 0-32kV (daidaitacce)
●Ƙimar wutar lantarki: 2000VA
●Matsakaicin makamashi: 2048J, 4uF
●Wutar lantarki ta DC: 32kV
●DC flashover halin yanzu: 63mA
●Max.impulse na yanzu: 500mA
●Hanyar fitarwa: DC HV, lokaci ɗaya, sake zagayowar
●Lokacin fitar da zagayowar: 3-6 seconds
●Yanayin muhalli: 0-40 ℃
●Humidity: <75% RH
●Tsayi: <1000m
●Insulation matakin: A
●Girma: 430*540*410mm
●Nauyi: kimanin 31kg.
Ciki har da mai watsawa, mai karɓa, binciken inductive, yuwuwar gano nau'inframe.Ya dace don gwada kowane nau'in kebul na wutar lantarki tare da madugu na ƙarfe.
Babban aikinsa shine gano madaidaicin wurin rufewa, gano kewaye dazurfin wutar lantarki.
●Babban hankali
●Motsi mara nauyi
●Babban daidaito na gano wuri
●Anti-tsangwama
●LCD allon don nuna sigina da matsayi
●Batir Li-batir mai caji
●Binciko da nisa: kebul na gida 3km, sauran kebul har zuwa 20km
●Gano kewayon impedance: 0-5MΩ.
●Daidaitaccen wuri: ≤± 10cm.
●Zurfin kebul na ganowa: <3m.
Yana iya gwada kurakuran filasha mai ƙarfi, babba-ƙanananjuriya grounding, short-circuit, na USB katse, rashin haɗin gwiwadon kowane nau'in igiyoyin wutar lantarki (digiri na ƙarfin lantarki 1kV-35kV),kebul na gida, kebul na sadarwa, kebul-coaxial da layin saman karfe.
Hakanan yana iya auna tsayin kebul da saurin yaɗa saurin igiyoyin lantarki akan kebul ɗin.
●Gwaji mai aminci, gaggawa da ingantaccen gwaji.Yana amfani da hanyar motsa jiki ta LV da gano HV flashover, wanda ke gwada kowane irin kurakuran na USB.Musamman don walƙiya da manyan kurakuran igiyoyi, ana iya gwada shi kai tsaye ba tare da ƙonewa ba;idan an sanye shi da ma'aunin ma'aunin sauti, ana iya tantance madaidaicin matsayi na laifin daidai.
●Yin amfani da fasahar samar da bayanai mai sauri.Gudun samfurin A/D shine 100Mhz, don sanya ƙudurin karatun kayan aikin shine 1m kuma wurin gano makafi shine 1m.
●Siffofin Wave da bayanai suna nunawa ta atomatik akan babban allon LCD.
●Siffar igiyar igiyar ruwa da ma'ajin siga, aikin tuna.
●Aiki na kwatanta nau'in gwaji na kuskuren kebul tare da tsarin igiyar ruwa ta al'ada.
●Wave form mika aikin.
●Nuna kuskure kai tsaye da wurin gwaji kai tsaye ko nisan dangi.
●Gyara saurin yaduwa kowane lokaci bisa ga igiyoyin gwaji daban-daban.
●Ginin baturi mai caji.Karamin girman, šaukuwa don ɗauka.
●Max.Tsarin gwaji: 15km (Buɗe waya har zuwa 100km).
●Gano makaho: 1m
●Tsawon: 1m
●Amfani da wutar lantarki: 5VA
●Yanayin muhalli: 0-40 ℃ (iyakance zazzabi: -10 ℃ - 50 ℃)
●Dangantakar zafi: 40 ℃(20~90)% RH
●Matsin yanayi: 86-106Kpa
●Girman: 275*220*160mm
●Nauyi: 1.8kg
Sauran na'urorin haɗi sun haɗa da AF Stethoscope, belun kunne, Pin Grounding, PD Locating Rack, RF Tracking Rod.