GD-4138H Tsarin Gano Laifin Kebul
GD-4138H Tsarin Gano Laifin Kebul na Waya shine kayan aiki mai mahimmanci don kula da kowane nau'in igiyoyi.Kayan aiki ne masu jituwa waɗanda zasu iya ganowa, gano igiyoyin igiyoyin ƙasa, tare da ma'aunin nisa na kuskure da tsarar HV.Da yake na'ura ce mai motsi, yana dacewa don ɗauka akan rukunin yanar gizon.Idan an yi amfani da mai gano sauti tare, zai iya nemo madaidaicin wurin ma'aunin laifin na USB.
Aikace-aikacen kebul na karkashin kasa, kebul na iska, kebul na wutar lantarki, kebul na gida, kebul na sadarwa da kebul na fiber.
●Laifin walƙiya mai girma
●High impedance yayyo
●High / low resistive grounding
●Laifi na gajeren lokaci
●Laifin buɗewa
●Rashin haɗin gwiwa / Cire haɗin gwiwa
●GD-4138H babban firam (Na'urar haɗawa, Sphere rata, HV janareta suna ciki)
●GD-4133 Multiple bugun jini na USB kuskuren gwaji
●GD-4132 Mai gano Laifin Cable
●Hanyoyi masu yawa masu yawa: Hanyar bugun jini mara ƙarfi, Hanyar bugun jini na yanzu, Hanyar bugun jini da yawa: samfur na yanzu, fitarwa na DC.
●Nau'in sigina na samfur: Hanyar tunani na DC Arc, Samfur na yanzu, Samfurin ƙarfin lantarki, ƙananan bugun jini.
●Gano wuri da sauri da nuna ƙananan juriya, kurakuran yabo mai tsayi da kurakuran filaye daban-daban na igiyoyi masu ƙarfin lantarki na 220V~220KV.
●Babu buƙatar aiwatarwahadaddun wayoyi don gwajin kan-site.Ana kunna duk hanyoyin gwaji ta atomatik ta cikin babban ƙarfin wutar lantarki na ciki wanda rashin ƙarfi na halin yanzu ke sarrafawa.
●Haɗaɗɗen janareta mai girman ƙarfin wutar lantarki mai yawa na DC, babban ƙarfin wutar lantarki mai saurin sauri, sashin daidaitawar baka da siginar sigina iri-iri a cikin ɗaya, mai sauƙin sarrafa tsarin wuri mara kyau.
●Multi-matakin fitarwa high ƙarfin lantarki sauyawa, duk sarrafawa ta ciki low irin ƙarfin lantarki na yanzu, aminci da abin dogara.
●Tsarin kayan aiki yana ɗaukar nauyin filastik mai ƙarfi.Shari'ar ita ce akwatin waje na kayan aiki da akwatin canja wuri don kunshin isar da kayan aiki.Ya dace don canja wurin, kuma ana iya ɗora shi da canja wurin kai tsaye lokacin da murfin ya rufe.
●Sphere tazara fitarwa: Rauni na yanzu iko solenoid bawul iska ratar, lokacin fitarwa ne daidaitacce daga 3 zuwa 12 seconds, kuma muffler an musamman tsara don saduwa da bukatun na bebe ga na USB gazawar a farkon.
●Kayan aiki yana da ginanniyar da'irar fitarwa.Bayan an gama gwajin kuskure, za a iya kashe babban ƙarfin lantarki kawai danna maɓallin a wurin fitarwa don fitarwa ta atomatik.
●Mai watsa shiri na auna nisa zai iya samar da ƙudurin auna nisa har zuwa 0.4m, kuma wurin auna ma'aunin karami ne, wanda ke da tasiri musamman ga kurakurai na kusa da gajerun igiyoyi.
●Ana shirya dukkan tashoshin fitarwa na kayan aiki akan bangon baya don sauƙaƙe wayoyi, kuma ana zana zane-zane na hanyoyin sadarwa daban-daban akan rukunin aiki, waɗanda mutane ba su da gogewa za su iya amfani da su cikin sauƙi.
●Ƙarƙashin kayan aiki yana sanye da ƙafafu masu ƙarfi 4 masu ƙarfi, waɗanda za'a iya turawa da tarawa don ajiya.
●Mai watsa shiri yana amfani da babban allo na 7-inch LCD tare da kusurwar kallo na 160 °, kuma abun ciki na nuni yana da wadata da fahimta.
●Ana iya adana adadi mai yawa na waveforms a cikin mai watsa shiri, kuma ana iya shigo da bayanan siginar igiyar ruwa da fitar da su ta amfani da diski U.
●Ana iya haɗa mai masaukin zuwa kwamfuta (tebur ko littafin rubutu) don sadarwar kan layi.
●Lokacin da mai watsa shiri ba shi da aiki a cikin mintuna 2, hasken baya zai raunana;idan ba a yi aiki na minti 10 ba, za a rufe ta atomatik don rage yawan amfani da wutar lantarki;lokacin da baturi ya yi ƙasa da ƙasa, kayan aikin kuma zai rufe ta atomatik don kare baturin.
●Mai watsa shiri yana da ginanniyar baturin lithium-ion polymer kuma an sanye shi da keɓaɓɓen cajar baturin lithium don samar da ingantaccen hanyar caji.
●Duk injin ɗin yana ɗaukar ƙirar tsarin akwatin canja wuri mai mahimmanci, wanda yake ƙanƙanta da ƙarfi, musamman dacewa don amfani da wurin gini.
Samfura | Saukewa: GD-4138L | GD-4138M | GD-4138H |
Yanayin gwaji | Hanyar tunanin Arc, samfurin yanzu, fitarwa na DC | Hanyar tunanin Arc, Hanyar tunani na baka na DC, samfurin yanzu, fitarwa na DC | |
Nau'in sigina na jeri | Hanyar duban bugun jini da yawa, samfurin yanzu, ƙananan bugun jini | Hanyar tunanin Arc, Hanyar tunani na baka na DC, samfurin yanzu, fitarwa na DC | |
DC HV fitarwa | 0~16KV mara kyau polarity Matsakaicin fitarwa na yanzu: 152mA | 0~32KV mara kyau polarity Matsakaicin fitarwa na yanzu: 76mA | 0~8KV korau polarity Matsakaicin fitarwa na yanzu: 304mA 0~16KV mara kyau polarity Matsakaicin fitarwa na yanzu: 152mA 0~32KV mara kyau polarity Matsakaicin fitarwa na yanzu: 76mA |
Flashover capacitance | 0-16kV 8μF Matsakaicin ƙarfin fitarwa: 1024J | 0-32kV 4μF Matsakaicin ƙarfin fitarwa: 2048J | 0-8kV 32μF Matsakaicin ƙarfin fitarwa: 1024J 0-16kV 8μF Matsakaicin ƙarfin fitarwa: 1024J 0-32kV 4μF Matsakaicin ƙarfin fitarwa: 2048J |
Fitar tazara ta atomatik ta atomatik | Rauni na yanzu iko solenoid bawul iska ratar, da fitarwa lokaci ne daidaitacce daga 3 zuwa 12 seconds, kuma muffler an musamman tsara don saduwa da bukatun na bebe ga na USB gazawar a farkon. | ||
Yanayin fitarwa | DC jure ƙarfin lantarki, fitarwa ɗaya, fitarwa na lokaci-lokaci | ||
DC juriya irin ƙarfin lantarki | 16KV | 32KV | 32KV |
Ƙunƙarar shigar da wutar lantarki mai ƙyalli | 16kV | 32kV | 32kV |
Ƙarfin shigar da aka yarda | <2048J | ||
Yanayin aiki | Zazzabi: 0 ~ 40 ℃ Dangantakar zafi: <75% RH | ||
Tushen wutan lantarki | AC220V, 50Hz | ||
Jimlar iya aiki | 3 kVA |
Ana amfani da shi don auna nisan kuskure.A ƙarƙashin yanayin bugun jini na LV, ana iya amfani da shi kaɗai.
7inch LCD allo, sada zumunci dubawa.
Hanyar gano nesa da yawa:
Hanyar bugun jini mara ƙarfi: ya dace da gano ƙarancin juriya, ƙarancin kewayawa, kuskuren kewayawa.Hakanan za'a iya amfani dashi a ma'aunin tsayin kebul, tsaka-tsakin haɗin gwiwa, haɗin T, da haɗin ƙare na USB.Hakanan ana iya amfani da wannan hanyar don gyara saurin igiyoyin ruwa.
Hanyar halin yanzu pulse: Ya dace da auna nisa na babban juriya, kuskuren lalacewa.Yin amfani da na'ura mai haɗawa na yanzu don tattara sigina daga waya ta duniya, yana sa mai amfani yayi nisa da babban ƙarfin lantarki.Wannan hanyar tana da aminci kuma abin dogaro.
Yawan bugun jini: hanyar ci gaba don auna nisa.Tsarin igiyar ruwa yana da sauƙin ganewa kuma daidaito yana da girma.
Samfurin 200MHz na ainihi.Max.0.4m ƙuduri ƙuduri.Yana da ƙananan mataccen yanki kuma na musamman don gajeriyar kebul ɗin kuma kusa da kebul na kuskure.
Taba allo kuma danna aikin maɓalli.Ana iya jan siginan kwamfuta.
Kwafin PIP (hoton ajiya na wucin gadi)
Za a sami babban taga kuma tagogin ajiya na wucin gadi uku za su iya duba nau'ikan igiyoyi uku tare.
Ginin tsarin aiki da aka saka
Gudanar da software na musamman don haɓaka software, wariyar ajiya da mayarwa.
Ayyukan sikelin
Mafari ɗaya na farawa, lambobin sadarwa 10, laifin kebul ɗaya da cikakken tsayi ɗaya na iya zama saiti.
Nuna ma'auni da sigar gwaji a lokaci guda
Waveform ajiya da sadarwa tare da kwamfuta.
Ciki ajiya na waveforms.
Tare da USB, don saukewa ko loda bayanai
Sadarwa tare da kwamfuta
Gudanar da wutar lantarki
Hasken baya yana rauni idan babu aiki a cikin mintuna 2 kuma a kashe wuta cikin mintuna 10 idan babu aiki.
Batir Lithium-ion Polymer da aka gina a ciki.
Lokacin aiki shine har zuwa awanni 5 don kowane amfani.
Harka mai ƙarfi, mai sauƙin ɗauka.
Hanyoyin ganowa | Hanyar ƙwanƙwasa ƙarancin wutar lantarki Ƙaddamar da hanyar halin yanzu Hannun motsa jiki da yawa |
Max.Mitar samfur | 200 MHz |
Riba iyaka | 0-70dB |
Ƙarƙashin ƙarfin wutar lantarki mai ƙarfi | 30V |
Matsakaicin ƙuduri | 0.4m ku |
Max.Gano kewayon | 100km |
Yankin matattu | 2m |
Baturi | Nickel-metal hydride baturi mai caji, lokacin juriya sama da awanni 5 |
Sadarwar sadarwa | USB |
Tushen wutan lantarki | Shigar da AC220V, 50Hz, 2A na yanzu, cajin sa'o'i 8 |
Dim. | 274×218×81mm |
Nauyi | 3.5kg |
Yanayin Aiki | -10 ℃-40 ℃ |
Danshi | 5-90%RH |
Girma | <4500m |
●Ana karɓar siginar sauti da maganadisu a lokaci guda.Ƙarfin ƙarfin hana tsangwama.
●Waveform nuni.
●Acoustic Magnetic waveform nuni.
●Gano wurin kuskure da gano hanya.
●Tare da kunnen kunne don jin hayaniya.
●320*240 LCD nuni, sada zumunta.
●Baturin Li wanda aka gina a ciki, tare da caja mai sauri.
●Zai kashe ta atomatik idan baya aiki bayan 15mins ko ƙarancin baturi.
●Ƙananan girman, sauƙin ɗauka.
●Saurin siginar Acoustic: mitar cibiyar 400Hz, bandwidth 200Hz
●Siginar riba: 80db.
●Daidaitaccen wuri: 0.1m
●Samar da wutar lantarki: ginanniyar baturi Li, ƙarancin ƙarfin lantarki 7.4V, 3000mAh, ci gaba da aiki 9hours.
●Caja: Shigar da AC220V±10%, 50Hz, na'urar fitarwa 8.4V, DC1A
●Lokacin caji: <4 hours
●Girma: 270*150*210mm.
●Nauyi: 1.5kg.
●Yanayin amfani: zazzabi -10--40 ℃, zafi 5-90% RH, tsawo <4500m.