GD-7018A Mai gano Fiber Optical
A GD-7018 jerin Tantancewar fiber bututun ganowa iya daidai gano wuri da kuma auna zurfin karkashin kasa bututun, igiyoyi da Tantancewar igiyoyi a karkashin yanayin ba tare da digging, da kuma daidai nemo lalacewar wuraren da m shafi na karkashin kasa bututun da kuma wurin da wuraren kuskuren kebul na karkashin kasa.Kayan aikin ya ƙunshi mafi yawan fasahar zamani kamar matattara mai kunkuntar band, sadarwar mara waya ta Bluetooth, sanya GPS, taswirar bayanai ta atomatik ta software na tantance bayanan ƙwararru da tsarar atomatik na rahotannin gwaji.Ganowa da duba bututun karfe iri-iri, sarrafa bututun mai da kula da bututun mai, tsare-tsare da gine-gine na kananan hukumomi, duba bututun mai a bangaren samar da wutar lantarki da sauran sassan na daya daga cikin abubuwan da ake bukata na sassan gyaran bututun.
(1) Ayyuka da yawa
1. Ayyukan watsawa: Yana da nau'ikan aikace-aikacen sigina guda uku na hanyar ƙaddamarwa, hanyar kai tsaye da hanyar matsawa, dacewa da lokuta daban-daban.
2. Ayyukan mai karɓa: Ana amfani da shi don auna wurin, shugabanci, zurfin binnewa da kuma halin yanzu a cikin bututun karkashin kasa da igiyoyi.
3. Kibiyoyi masu matsayi na hagu da dama suna nuna wurin bututun da aka yi niyya, kuma wurin yana da sauri kuma daidai;kibiyoyi na gaba da na baya da ƙimar dB suna nuna wuri da girman wurin lalacewa na Layer anticorrosive.
4. Tare da aikin hasken baya, dace da ceton gaggawa da dare.
5. GPS wurin sakawa aiki, taswirar bututu ta atomatik.
6. ƙwararrun software na nazarin bayanan ƙwararru, ƙaddamar da rahoton gwaji ta atomatik.
7. Ayyuka na musamman na mai karɓa na 7018E: Ana amfani da shi don gano kuskure (rashin bututun yana nufin lalacewa na waje na anti-corrosion Layer, gazawar na USB yana nufin lalacewa na kariya na waje), da kuma gano lalacewar lalacewa. na bututun karkashin kasa.
8. Ma'auni na yanzu: auna halin yanzu da mai watsawa ya yi amfani da shi zuwa bututun da ke ƙarƙashin gwaji.
9. Ayyukan Multimeter: yana iya auna ƙarfin fitarwa, ƙarfin layi, layin layi, impedance da iko.Gwada ci gaba da ingancin kebul ɗin kafin da bayan binciken laifin na USB.
10. Ƙwaƙwalwar shigarwa na waje: dace da wurin da ba za a iya haɗa siginar kai tsaye ba lokacin gano kebul.
(2) Babban matsayi daidai
1. Hanyoyin ma'auni iri-iri don saka bututun bututu (yanayin kwari, yanayin kololuwa, yanayin tsayi mai faɗi, yanayin kibiya mafi girma) ana iya tabbatar da juna don tabbatar da daidaiton saka bututun.
2. Hanya mafi girma: yanayin kololuwa, yanayin kololuwa mai faɗi, yanayin kibiya kololuwa ana iya amfani da shi don auna canjin sassa na kwance ((HX)) ko a kwance (△HX), kuma gano wuri gwargwadon matsayin matsakaicin ƙimarsa;
3. Hanyar mafi ƙanƙanci: Yi amfani da yanayin ƙasa don ƙayyade matsayi mafi ƙarancin ƙima ta hanyar auna canjin ɓangaren tsaye (HZ).
(3) Akwai hanyoyi masu sauti da yawa
1. Daban-daban hanyoyin ganowa ana iya zaɓar su ba bisa ka'ida ba kuma ana iya tabbatar da juna.
2. Hanyar karantawa kai tsaye tare da coils a kwance biyu.
3. Single matakin nada 80% Hanyar, 50% hanya.
4. Hanyar digiri 45.
(4) Karfin tsangwama
1. Matsalolin kallo da yawa: ana iya auna su duka biyun a kwance (HX), bangaren tsaye (HZ) da kuma a kwance (△HX).
2. Babban ikon watsawa: Ƙarfin fitarwa na mai watsawa ya kai 10W kuma yana ci gaba da daidaitawa.Ana iya zaɓar ta bisa ga buƙatu.
3. Ƙarin mitoci masu aiki:
Mitar watsawa: 128Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
Mitar mai karɓa: rediyo, 50Hz, 100Hz, 512Hz, 1KHz, 2KHz, 8KHz, 33KHz, 65KHz, 83KHz.
4. Dangane da halaye na bututun da aka yi niyya (kayan abu, tsari, zurfin binne, tsayi, da dai sauransu), zaɓi mitar aiki mai dacewa.
(5) Aiki mai sauki
1. Intuitive: Ana amfani da nunin hoto don ci gaba da nuna ainihin lokaci daban-daban sigogi da ƙarfin sigina yayin aikin ganowa.
2. Atomatik: Canja ta atomatik zuwa yanayin eriya-dual-level kuma ta atomatik daidaita ma'aunin mai karɓa yayin auna zurfin, don cimma siginar ma'auni mafi kyau, kuma ta atomatik komawa yanayin aiki kafin bayan kammalawa.
(6) Tsawon lokaci mai ci gaba da aiki da ƙarancin amfani
Na'urar watsa shirye-shiryen tana da babban baturin lithium, wanda zai iya biyan bukatun samar da wutar lantarki na rana guda don gano filin da caji daya, kuma ana iya sake yin amfani da shi, wanda ke rage farashin ganowa sosai.
(7) Mai watsawa --AC da DC dual-amfani
Karkashin yanayi na al'ada, idan baturin watsawa ya cika, yi amfani da fakitin baturi don samar da wuta.Idan lokacin amfani, baturin mai watsawa yana da ƙasa, amma aikin ganowa bai cika ba, zaku iya haɗa adaftar wutar lantarki kai tsaye, ana iya amfani da kayan aiki akai-akai, ba tare da jira na'urar ta cika caji ba kafin amfani.
Sigar Fasaha | Ajerin | Bjerin | Cjerin | Djerin | Ejerin |
Gano Mitar | 5 | 6 | 7 | 8 | 10 |
Yawanci | 512,1K,33K,83K | 512,1K,33K,83K | 512,1K,33K, 83K | 512,1K,33K,65K,83K | 512, 1K, 2K, 33K, 65K, 83K |
Mitar wucewa | 50Hz | 50 Hz 100 | 50Hz 100 Hz rediyo | 50Hz 100 Hz rediyo | 50Hz 100 Hz rediyo |
Tace Wuta | × | × | √ | √ | √ |
Mitar Laifi | × | × | × | × | 2 |
Gano kuskure | × | × | × | × | √ |
Batirin lithium ion | √ | √ | √ | √ | √ |
A Frame | × | × | × | × | √ |
Gano Zurfin (m) | 6 | 6 | 6 | 6 | 6 |
Adana bayanai | × | × | × | √ | √ |