GD3127 Series High Voltage Insulation Resistance Gwajin
GD3127 Series Insulation Resistance Tester ana amfani dashi ko'ina don kiyaye kayan aikin lantarki a cikin tashar wutar lantarki, injin wutar lantarki, da sauransu. RAMP), tace (FR, 10s, 20s, 30s, 40s 4 choices), ƙarfin lantarki (V), na yanzu (nA) na kowane nau'in kayan aikin wutar lantarki mai ƙarfi, gami da switchgear, masu wuta, reactors, capacitors, motors, janareta da igiyoyi, da dai sauransu.
Jerin GD3127 shine cikakkiyar kayan aikin gwaji don gano wuri da gano tsare-tsaren kiyayewa ko tsinkaya don yuwuwar gazawar kayan aiki.Yana da mahimmanci don tabbatar da ingancin samfurin da amincin mutane da kayan aiki a cikin aiki.Ayyukan haɓakar kayan aikin lantarki yana ɗaya daga cikin mahimman alamun don kimanta ingancin haɓaka, wanda aka nuna ta hanyar gwajin juriya.
●Max.gajeriyar halin yanzu> 5mA.
●Insulation juriya (IR), polarization index (PI), sha rabo (DAR).
●Ramp (RAMP), tace (FR), ƙarfin lantarki (V).
●Kula da wutar lantarki ta atomatik na abin da aka auna, kuma ta atomatik haramta gwajin idan ƙarfin lantarki ya wuce 36V, wanda ke ba da kariya ga kayan aiki da mai aiki yadda ya kamata.
●Ayyukan lokaci, rikodin lokacin gwaji ta atomatik.
●Fitar da babban ƙarfin lantarki ta atomatik bayan an gama aunawa, lokacin fitarwa bai wuce daƙiƙa 30 ba.
●Aikin kashe wuta ta atomatik.
●Babban nunin matrix ɗigon allo na LCD tare da ingantaccen aiki.
●Tsarin harsashi biyu-Layer, mai ƙarfi kuma mai dorewa, matakin kariya IP65.
●Babban fakitin baturin lithium mai iya caji.
●Ayyukan ajiya, na iya adana saiti 1000 ta atomatik na bayanan gwaji na ainihi tare da kwanan wata da lokacin gwaji da lokacin gwaji.
●Ayyukan loda, sanye take da kebul na USB, ana iya loda bayanan rikodin zuwa kwamfuta don ƙididdigar ƙididdiga na bayanai.
Aiki | Insulation juriya (IR), polarization index (PI), sha rabo (DAR), ramp (RAMP), tace (FR, 10s, 20s, 30s, 40s 4 zabi), ƙarfin lantarki (V), halin yanzu (nA) |
Tushen wutan lantarki | Mai cajibaturi lithium5.2 ah |
Ƙarfin wutar lantarki | GD3127: 250V, 500V, 1kV, 2.5kV, 5kV GD3127B: 250V, 500V, 1kV, 2.5kV, 5kV, 10kV |
Fitar wutar lantarki adaidaito | (5% -10%)±10V |
Ma'aunin aunawa juriya | GD3127:0.50MΩ~2.00TΩ GD3127B: 0.50MΩ~5.00TΩ |
Short circuit current | > 5mA |
Fihirisar Polarization (PI) | Ee |
Rabon sha (DAR) | Ee |
Yanayin gwajin Ramp (RAMP). | Gwaji cikin matakan 10% na ƙarfin lantarki da aka saita har sai an saita ƙarfin lantarki |
Tace yanayin gwaji | Zaɓuɓɓuka huɗu na 10S, 20S, 30S, 40S |
Gwajin wutar lantarki | Kewaye: AC/DC 0V-1000V, daidaito:±5%rdg±3V |
Gwajin yanzu | Rage: 0.01nA-7mA, daidaito:±5%rdg±0.5nA |
Mai duba wutar lantarki | Kula da wutar lantarki na abin da aka gwada, lura da yanayin fitarwa bayan gwajin, kuma hana gwajin lokacin da ƙarfin lantarki ya fi 36V, kare kayan aiki da mai aiki |
Gwaji mai ƙidayar lokaci | Yi rikodin lokacin gwaji ta atomatik, kewayon lokaci: 0s~9999s |
Adana | Adana bayanan gwaji ta atomatik tare da kwanan wata da lokaci, jimlar ƙungiyoyi 1000 |
Sadarwa | Loda bayanan gwajin da aka adana zuwa kwamfuta ta hanyar layin sadarwa na USB. |
Baturi | Akwai nuni matakin baturi, tunatarwa don yin caji cikin lokaci lokacin da ƙarfin baturi ya yi ƙasa |
Aikin kashe wutar lantarki ta atomatik | Kashe wuta ta atomatik bayan mintuna 15 |
Ajin kariya | IP65/IP40 |
Juriya na rufi | 50MΩ(1000V) (tsakanin gwajin gwaji da harsashi) |
Juriya irin ƙarfin lantarki | AC 3kV 50Hz 1 min (tsakanin gwajin kewayawa da harsashi) |
Matsayi | Saukewa: IEC61010-1 |
Yanayin aiki da zafi | - 20℃ ~ +50 ℃ <80% RH |
Yanayin ajiya da zafi | - 25℃ ~ +65℃80% RH |
Tushen wutan lantarki | 220V AC 50Hz |
Girma (mm) | 280(L)*260(W)*160 (H) |
Nauyi | 4400g (ya hada da baturi) |
Gwajin juriya na rufi | 1 saiti |
High ƙarfin lantarki gwajin waya (Jan) | 1 yanki |
Gwada waya(Green) | 1 yanki |
Gwajiwaya(Bakar) | 1 yanki |
Adaftar wutar lantarki | 1 piece |
Mai amfani's jagora | 1 kwafi |
Gwajirfitarwa | 1 kwafi |