GDB-H Mai Canjin Hannu ta atomatik Yana Juya Gwajin Ratio
GDB-H na'urar hannu ce.Yana iya auna jujjuyawa daidai gwargwado, rukuni da kusurwar lokaci, wanda ya dace da kowane nau'ikan tasfoma kamar su na'urorin wuta na nau'in Z, na'urar gyara tawul, injin tanderu na wutar lantarki, na'urorin canza yanayin lokaci, na'urar wutar lantarki, scott da invert-scott.
●5.6inch TFT launi LCD allo, da ilhama nuni bayanai da vector zane.
●3-gwajin gwaji lokaci guda.Shigar da wutar lantarki lokaci ɗaya, tare da haɗin dijital na ciki daidaitaccen tushen gwajin igiyar igiyar ruwa.Yana haifar da ƙarfin gwaji na lokaci 3 (digiri na murdiya bai wuce 0.1% ba, matakin daidaitawa ya fi 0.05%) ta ƙarfin ƙarfin ƙarfin Hi-fi.Sakamakon gwajin ya fi daidai, kuma ba zai bayyana kuskuren yanke hukunci ba.
●Duk ma'aunin lokaci guda ɗaya da gwajin atomatik na lokaci 3.Yana iya auna polarity da kusurwar lokaci a ƙarƙashin lokaci ɗaya ko gwajin lokaci 3.Lokaci guda cika ma'aunin juyi, ƙimar kusurwar lokaci, kuskure, matsayi na famfo, ƙimar famfo AB, BC, CA.Ana iya gano lambar rukuni ta atomatik.
●Ayyukan ma'aunin kusurwa.Daidai auna kusurwar lokaci tsakanin babban ƙarfin lantarki da ƙananan ƙarfin lantarki.Yana kuma iya auna jujjuya rabo da kusurwar masu taswirar “Mahimmanci”.
●Ana nuna sakamakon gwajin ta siffa da kuma vector hexagonal, kai tsaye suna nuna rukunin haɗin gidan wuta.
●Babu buƙatar zaɓar hanyar haɗin kai ko ƙungiyar haɗin gwiwa, tana iya auna Y/△, △/Y transformer ba tare da gajeriyar haɗin waje ba.Hakanan yana iya canza hanyoyin haɗin kai bisa ga zaɓin abubuwan gwaji.Transformer ba tare da farantin suna ba za a iya aunawa.
●Da sauri auna rabon juyi da kuskuren rabo na kowane matsayi mai canza famfo.Matsakaicin ƙimar shigarwa kawai sau ɗaya, babu buƙatar maimaita shigarwa don ƙididdige kuskuren rabo na kowane matsayi na famfo.
●Tare da ayyuka na ma'aunin juyi biyu da ma'aunin ƙimar ƙarfin aiki.Matsakaicin aiki na iya nuna ainihin ƙimar ƙimar ƙarfin lantarki yayin aiki.
●Tare da kyakkyawan juriya na girgiza.
●Tushen gwajin wannan kayan aikin shine madaidaicin tushen igiyar igiyar ruwa.Digiri na murdiya bai wuce 0.1% ba, ingancin wutar lantarki bai shafe shi ba.
●Ƙananan girman, nauyi mai sauƙi, sauƙin ɗauka.
●Batir Lithium-ion da aka gina a ciki mai ƙarfi mai ƙarfi.Ana iya kammala gwajin ba tare da wani iko ba.Cikakken caji na lokaci ɗaya yana ɗaukar fiye da sau 800 ci gaba da aunawa.
●Za'a iya adana bayanan daidaita filin, kuma ana iya canza sakamakon zuwa PC ta U disk.
●Ma'aunin TTR: 0.8 ~ 10000.
●Saurin aunawa: Ana iya kammala gwajin mataki uku a cikin daƙiƙa 60.
●Daidaiton aunawa:
Daidaitaccen ma'aunin wutar lantarki a gefen HV: 0.05%
Daidaitaccen ma'aunin wutar lantarki a gefen LV: 0.1%
Daidaiton ma'aunin kusurwa na lokaci: 0.1°
Daidaitaccen ma'aunin TTR: 0.1% (0.8-3000)
0.2% (3000-10000)
●Nauyi: kusan 3Kg.
GDB-H kayan aiki | 1pc |
Kayan haɗi | 1pc |
Gubar Gwajin HV tare da manne | 1 saiti |
Gubar Gwajin LV tare da manne | 1 saiti |
Fuse | 2pcs |
Caja | 1pc |
Jagorar mai amfani | 1pc |
Rahoton gwajin masana'anta | 1pc |