GDBR-P Mai Canjawa Load No-load and Capacity Tester
●Auna transformer No-load current, No-load loss, short circuit voltage, short circuit loss da kuma iya aiki.
●Hanyoyin gwaji na mita uku.
●Lokacin yin na'ura mai canzawa na lokaci uku Babu-load, gwajin kaya, kayan aikin zai yi hukunci idan na'urar ta dace ta atomatik, kuma tana nuna ƙarfin lantarki na lokaci uku, zane na yanzu.
●Kammala gwajin lodi a ƙarƙashin 1600kVA ƙasa mai rarraba wutar lantarki cikakke na injin guda ɗaya.Ƙare 2500kVA a ƙasa gwajin lodin wutar lantarki a ƙarƙashin 1/3 wanda aka ƙididdige halin yanzu (A ƙarƙashin 1/3 rated na yanzu, ana iya canza kayan aikin zuwa sigogin asarar nauyi a ƙarƙashin ƙimar halin yanzu.)
●Ana gyara duk sakamakon gwaji ta atomatik.Kayan aikin gyaran atomatik kamar haka, gyare-gyaren igiyar igiyar ruwa, gyaran zafin jiki, Ƙimar wutar lantarki da ba a ƙididdigewa ba da kuma gyaran da ba a ƙididdigewa ba.Sakamakon gwajin ya fi daidai.
●320*240 babban allon LCD mai haske, tare da daidaitawar haske.Maɓallin taɓawa suna sa aikin ya fi dacewa.
●Agogon lokaci na ainihi, rikodin ranar gwaji ta atomatik, dace da ajiya da sarrafa sakamakon gwaji.
●Gina-in-nau'in panel na thermal printer, sakamakon gwajin bugun sauri.
●Ƙaddamar da ma'ajin da kuma bincika bayanai (saitin abu na gwaji, sakamakon aunawa, lokacin gwaji) ayyuka.Adana sakamakon gwaji har zuwa ƙungiyoyi 500, watsa bayanai akan layi zuwa PC.
●Yana ba da damar auna kewayon tsawaita don injin wutar lantarki na waje da na'ura mai canzawa na yanzu.Auna gwajin abu na kowane sigogi.
1. Gwaji abubuwa
●RMS na ƙarfin lantarki na lokaci uku: Uab, Ubc, Uca.
●Matsakaicin ƙimar ƙarfin wutar AC na zamani uku: Uab, Ubc, Uca.
●RMS na halin yanzu lokaci uku: Ia, Ib, Ic.
●Kashi na asarar No-load da No-load halin yanzu: Po, Io%.
●Asara mai ɗaukar nauyi, kaso na ƙarfin lantarki na impedance, ƙarancin kewaye: Pt, ekt, Zt.
●Asara mai lodi, yawan ƙarfin lantarki da gajeriyar da'ira a kowane ƙayyadadden zafin jiki.
●Mai jujjuya ƙarfin gaske da ƙarfin da aka yanke hukunci.
2. Babban sigogi na fasaha
●Matsayin ma'auni na yanzu: 100mA-60A, daidaito: aji 0.2.
●Matsakaicin ma'aunin wutar lantarki: 10V-650V, daidaito: aji 0.2.
●Transformer na waje na iya faɗaɗa kewayon ma'aunin kayan aiki.
●Matsakaicin ma'auni: 40-65Hz, daidaito: aji 0.2.
●Shigar da wutar lantarki: AC220V± 10%.
Babban Unit | 1 pc |
Igiyar wutar lantarki | 1 pc |
Cable gwajin manne | 1 saiti |
Kebul na gajeriyar kewayawa ta musamman | 1 pc |
Jagorar mai amfani | 1 pc |
Rahoton gwajin masana'anta | 1 pc |