GDBT-1000kVA Transformer Test Bench

GDBT-1000kVA Transformer Test Bench

Takaitaccen Bayani:

 

 GTsarin Gwajin Canjin DBT na iya gudanar da duk gwaje-gwaje na yau da kullun don masu canji, gami da No-load da gwajin lodi, Gwajin ƙarfin lantarki da aka ƙirƙira, gwajin jurewar wutar lantarki, gwajin fitarwa na yanki, gwajin juriya na DC, gwajin juzu'i, gwajin tashin zafin jiki da sauransu.

 

 

 


Cikakken Bayani

Tags samfurin

GDBT Transformer Test System(3)
Janar bayani

Abun Gwaji:
22.9kV Single Phase transformers da na musamman masu canji,Load ƙarfin lantarki da halin yanzu: AC 0-650V/78A, AC 0-1200V/29A, AC 0-2400V/14.6A
Matsalolin da aka gwada ta wuta yana tsakanin 7%, HV gefen shine 23kV, 11kV, 6kV.LV gefen 0.05kV-2.4kV.

Wannan benci na gwaji na iya yin gwajin a ƙasa:
1. Gwajin ba tare da ɗora nauyi ba gami da asarar nauyi, kashi dari na ƙarancin kaya zuwa halin yanzu.
2. Gwajin gwaji ciki har da asarar nauyi, yawan ƙarfin lantarki na impedance, canjin zafin jiki ta atomatik da gwajin asarar nauyi a ƙarƙashin 30% ko sama da cikakken halin yanzu.
3. Jarabawar ƙarfin lantarki.

Siffofin

Yi rikodin bayanan gwajin da hannu kuma adana a cikin ma'ajin bayanai.
Za'a iya gyara bayanan gwajin No-load ta hanyar igiyar ruwa da ƙimar ƙarfin lantarki ta atomatik.
Ana iya gyara bayanan gwajin Load ta zazzabi (75 ℃, 100 ℃, 120 ℃, 145 ℃) da rated halin yanzu.
A cikin gwajin No-load, ana iya sa ido kan ƙarfin lantarki na gefen LV.
A cikin gwajin Load, ana iya lura da halin yanzu na gefen HV.
Ana iya zaɓar duk ayyukan gwaji da tsarin gwaji da maɓallan ɓangaren gaba.
Ana gyara duk sakamakon gwajin bisa ga buƙatun GB1094, IEC60076 ko ANSI C57.
Ana iya aiwatar da tsarin gwaji ta software na PC.
Ana iya adana duk bayanai da buga su.
Tare da kariyar sifili, kariya ta yau da kullun da ayyukan kariyar ƙarfin lantarki.
Canja kewayon CT/PT ta atomatik.
Benci na gwaji zai yi cikakken iko zuwa duk kewayen madauki kuma yana kula da ma'auni.
Tsarin ƙararrawa na aminci.

Ƙayyadaddun bayanai

Load Mai Canjawa da Gwajin No-Load (Kawai don tunani, ƙirar ƙarshe shine Fluke Norma 4000)

Wutar lantarki: 0-1000V
Kewayon halin yanzu: 0.25-20A, daidaito 0.2%.
Daidaitaccen wutar lantarki 0.3%.
Matsakaicin ƙarfi 0.050-1.000, daidaito 0.3%
Mitar 40-70Hz, daidaito 0.1%.
Wutar P
No-load na yanzu Io, %
Babu-kaya asara Po
Load da kaya Pk
Impedance ƙarfin lantarki Uk
Power Po
Matsakaicin ƙarfin lantarki Un
Matsakaicin halin yanzu In.

HV CT bayani dalla-dalla
Wutar lantarki: 3kV
Ma'auni: 0.25A-110A
Daidaito 0.05%
Matsakaicin juyi shine 100,50,30,20,10,5,2.5/1A
 
Bayanan Bayani na PT
Wutar lantarki: 0.1kV-3kV(50Hz-400Hz)
Daidaito 0.05%
Juyawa rabo shine 3,2,1,0.5kV/0.1kV

Samar da Wutar Lantarki Mai Sauyawa
Input irin ƙarfin lantarki: Single lokaci AC380V, 60Hz
Ma'auni: 0-800V
Yawan aiki: 30kVA
Fitowa na yanzu: 0-37.5A
Mitar fitarwa: 180Hz, 240Hz, 400Hz± 2%

Matsakaicin Transformer
Yawan aiki: 40kVA
Input Voltage: Single lokaci 500V
Wutar lantarki mai fitarwa: 0-650V-1200V-2400V

100kVA Single Phase Regulator
Input irin ƙarfin lantarki: Single lokaci 380V/60Hz, fitarwa ƙarfin lantarki 20-650V.
Max.Saukewa: 154A
Ba tsarin lamba ba ne, mai sauƙin amfani.
Lokacin da ƙarfin shigarwa ya kasance akai-akai, yana iya daidaita ƙarfin wutar lantarki cikin sauƙi tare da kaya.An tsara shi ta mitar 60Hz.

Bukatar Zane

Duk gwajin da ake buƙata an sanye su a benci iri ɗaya, kowane aiki mai zaman kansa ne.Duk gwajin atomatik ne.
Gwajin Halayen Transformer(Babu lodi da Gwajin Load)
Ana sarrafa shi ta PC kuma ana ba da shi induced mai sarrafa wutar lantarki 100kVA, mai canzawa mai matsakaici 40kVA.

Za mu iya keɓance nau'ikan ƙima daban-daban dangane da ainihin buƙatu.

Bayanin Kamfanin

GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester8
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester9
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester10
GD6100C Transformer Insulation Oil Tan Delta Tester Oil Dielectric Tester11

  • Na baya:
  • Na gaba:

  • Aiko mana da sakon ku:

    Ku rubuta sakonku anan ku aiko mana

    Aiko mana da sakon ku:

    Ku rubuta sakonku anan ku aiko mana