GDC-9560B Tsarin Wutar Lantarki Mai Nazari Chromatograph Mai Nazari
GDC-9560B Gas Chromatograph Analyzer shine yin nazarin abun cikin iskar gas na mai mai rufi ta hanyar iskar gas.Yana da tasiri don yin hukunci idan kayan aikin yana da kuskure kamar zafi mai zafi, fitarwa ko a'a, don tabbatar da amincin grid ɗin wutar lantarki.Hakanan ya zama dole a yi amfani da kayan aikin iskar gas / mai don bincika kayan aikin su kafin barin masana'anta.
Fasahar bincike na chromatography na iskar gas wata dabara ce don rarrabuwa da bincike na gaurayawan abubuwa da yawa.Yafi amfani da bambanci na tafasa, polarity da adsorption coefficient na kowane bangare a cikin samfurin a cikin ginshiƙi, sabõda haka, an rabu da aka gyara a cikin ginshiƙi, da kuma rabu da aka gyara da qualitatively da quantitatively nazari.
Gas chromatograph yana amfani da iskar gas a matsayin lokaci na hannu (gas mai ɗaukar kaya).Lokacin da aka aika samfurin zuwa mai injector kuma ya vaporized, iskar gas yana ɗaukar shi a cikin ginshiƙi mai cike da ginshiƙai ko ginshiƙan capillary saboda wurin tafasa, polarity da adsorption coefficient na kowane bangare a cikin samfurin.Bambanci shi ne cewa an raba abubuwan da ke cikin ginshiƙi, sa'an nan kuma an gano na'urorin da ke da alaƙa da ginshiƙi a jere bisa ga halayen physicochemical na abubuwan, kuma a ƙarshe ana aika siginar lantarki da aka canza zuwa wurin aiki na chromatographic.Ana yin rikodin chromatogram na iskar gas na kowane bangare kuma an bincika shi ta wurin aiki na chromatographic don samun sakamakon bincike na kowane bangare.
●Yana ɗaukar ci-gaba na 10/100M adaftar hanyar sadarwa ta hanyar sadarwa ta Ethernet da kuma ginanniyar ka'idar yarjejeniya ta IP, wanda ke ba kayan aikin damar fahimtar watsa bayanai mai nisa cikin sauƙi ta hanyar LAN na ciki da Intanet.Yana sauƙaƙe saitin dakin gwaje-gwaje kuma yana sauƙaƙe dakin gwaje-gwaje.Tsarin yana sauƙaƙe sarrafa bayanan nazari.
●Zane na hanyoyin haɗin kai 3 masu zaman kansu.Ana iya haɗa shi tare da aiki na gida (ɗakunan gwaje-gwaje), mafi dacewa ga masu kulawa don saka idanu da matsayi da kuma nazarin sakamakon.
●Wurin aiki na NetChromTM na zaɓi yana iya tallafawa lokaci guda chromatographs da yawa don sarrafa bayanai da sarrafawa, sauƙaƙe sarrafa takardu da rage saka hannun jari na mai amfani da kuɗin aiki.
●Tsarin a cikin Ingilishi da Sinanci, wanda za'a iya canzawa kyauta.
●Yankin kula da zafin jiki na iya samun sunan mai amfani kyauta, wanda ya dace da masu amfani.
●Yin amfani da yanayin aiki mai jujjuyawar multiprocessor, mafi kwanciyar hankali kuma abin dogaro.Ya hadu da hadadden bincike na samfurin.An sanye shi da nau'ikan na'urori masu aiki da yawa kamar FID, TCD, ECD, da FPD.Ana iya shigar da gwaje-gwaje har zuwa hudu a lokaci guda.Hakanan yana yiwuwa a yi amfani da hanyar ƙari na ganowa, wanda ya dace don siye da shigar da wasu na'urori bayan siyan kayan aiki.
●Kayan aiki yana ɗaukar tsari na zamani, ƙira da maye gurbinsu, mai sauƙin haɓakawa da kare tasirin saka hannun jari.
●Sabuwar tsarin kula da zafin jiki na microcomputer yana da madaidaicin sarrafa zafin jiki da ingantaccen inganci da aikin hana tsangwama.Yana da tsarin kula da zazzabi mai zaman kansa guda shida, wanda zai iya gane shirye-shiryen zafin jiki na matakai 16, wanda ke sa kayan aiki su sami damar yin nazarin samfurin.Yana da tsarin buɗe ƙofar baya ta atomatik don tanda, wanda ke inganta daidaiton ƙarancin zafin jiki kuma yana ƙara saurin tashi / raguwa.
●Ana iya sanye da kayan aikin tare da ci-gaba mai kula da kwararar lantarki (EFC) da mai kula da matsa lamba na lantarki (EPC) don gane sarrafa dijital, wanda zai iya inganta haɓakar sakamako mai ƙima da ƙididdiga.
●Shirye-shiryen farawa na lokaci na kayan aiki na iya kammala nazarin samfuran gas cikin sauƙi akan layi (yana buƙatar sassan allura ta atomatik akan layi).
●Tsarin aiki na maballin sarrafa microcomputer yana da sauƙi kuma ya dace don aiki;kuma an tsara fasahar ganowa ta atomatik na mai ganowa.Tare da gano kuskure da kariyar bayanan kashe wuta, ana iya haddace sigogi ta atomatik.
●Kayan aikin yana da ƙananan ƙaramar ƙararrawa, babban ƙuduri na 24-bit AD tare da ajiyar tushe da raguwa na asali.
●Tattara sigina na chromatographic da sarrafa bayanai, dacewa da WinXP, Win2000, Windows7 da sauran tsarin aiki.Ana karanta samfurorin bayanai daga fayilolin CDF waɗanda suka dace da ka'idodin A/A (Ƙungiyar Analytical Society), don haka ana iya amfani da su tare da Agilent, Waters da sauran wuraren aiki na chromatography.
●Tsarin Chromatographic tare da cikakken haƙƙin mallaka na ilimi mai zaman kansa, tare da daidaitaccen keɓancewar yanayin MODBUS/TCP, ana iya kulle shi cikin sauƙi tare da DCS.
●Ana iya haɗa kayan aiki tare da samfurin auto wanda yawancin masana'antun gida da na waje suka samar;kamar Shimadzu AOC-20i, HTA kamfanin HT jerin high-inganci ruwa, gas auto sampler.
Gane gas | H2, CO, CO2, CH4, C2H4, C2H6, C2H2.Gas (7)O2(na zaɓi), N2 (na zaɓi) |
Display | 192*64 dige matrix LCD |
Wurin sarrafa zafin jiki | 6 hanyoyi |
Kewayon sarrafa zafin jiki | zazzabi +5℃~400℃, karuwa 1℃, daidaito:±0.1℃ |
odar shirye-shirye | Matakai 16 |
Yawan tashin shirin | 0.1~40℃/min |
sarrafa gas | Yanayin sarrafa bawul na inji, yanayin sarrafa matsa lamba na lantarki na zaɓi |
Abubuwan da suka faru na waje | 4 tashoshi |
Nau'in allura | cushe shafi, capillary, shida bawul gas allura, atomatik headspace allura, da dai sauransu. |
Yawan ganowa | 4 inji mai kwakwalwa;FID, TCD, ECD, FPD (na zaɓi) |
Fara allura | manual, atomatik na zaɓi |
Sadarwar sadarwa | Ethernet: IEEE802.3 |
Ƙididdigar Mai ganowa | |
Mai gano harshen wuta na hydrogen (FID) | |
Iyakar ganowa | ≤ 2 × 10-11g / s (n-hexadecane / isooctane); |
Hayaniyar tushe | ≤ 5 × 10-14A |
Tushen tushe | ≤ 1 × 10-13A / 30 min |
Kewayon layi | ≥106 |
Mai Neman Haɓaka Ƙarfafawa (TCD) | |
Hankali | S≥2500mV•ml/mg (benzene/toluene) (maganin 1, 2, 4, 8 sau na zaɓi) |
Hayaniyar tushe | ≤20μV |
Tushen tushe | ≤30μV/30min |
Kewayon layi | ≥104 |
Mai gano kama kayan lantarki (ECD) na zaɓi | |
Iyakar ganowa | ≤ 1 × 10-13g / ml (propylene hexa-6 / isooctane) |
Hayaniyar tushe | ≤0.03mV |
Tushen tushe | ≤0.2mV/30min |
Kewayon layi | 103 |
tushen rediyoaktif | 63 Ni |
Mai Gano Hoton Hoto (FPD) na zaɓi | |
Iyakar ganowa | (S) ≤ 5×10-11g/s, (P) ≤ 1×10-12g/s;methyl parathion / cikakken ethanol) |
Hayaniyar tushe | 3 × 10-13A |
Tushen tushe | ≤ 2 × 10-12A / 30 min |
Kewayon layi | Fko sulfur ≥ 102, don phosphorus ≥ 103 |
Gas Chromatograph Babban Unit | 1 saiti |
Hydrogen janareta | 1 saiti |
janareta na iska | 1 saiti |
Multi-aiki Shaker | 1 saiti |
Matsakaicin Rage Rage Matsi | 1 saiti |
Rage Matsi Na Nitrogen Valve | 1 saiti |
Nitrogen Silinda | kwalba 1 |
Daidaitaccen gas | kwalba 1 |
Hanyar Gas nut M8X1Φ3.2 | 10 inji mai kwakwalwa |
Matsa lamba rage haɗin bawul | 5 guda |
Kwayar ginshiƙin capillary % 0.8 | 4 guda |
Kwayar ginshiƙi Φ4.2 da Φ3.2 | Kowane 5 inji mai kwakwalwa |
Bakin karfe gas na ciki bututu Φ2 | 10 inji mai kwakwalwa |
Gas hanyar rufe kushin | 50 guda |
Capillary sampler evaporative kushin | 50 guda |
Kunshin graphite na capillary % 0.8 | 20 inji mai kwakwalwa |
Kunshin hoto Φ4.2 da Φ3.2 | Kowane guda 10 |
Fuse | 4 guda |
Saukewa: M3X5 | 6 guda |
PE gas bututu Φ3 | 20m |
1ml filastik injector | 5 guda |
100 ml injector | 5 guda |
Allura | 10 inji mai kwakwalwa |
20ml gilashin injector | 5 guda |
5ml gilashin injector | 5 guda |
1ml gilashin injector | 5 guda |
Tambarin ƙididdigewa | 2 guda |
Vaseline 30 g | 2 guda |
Screwdriver 50mm 70mm | Kowane 1 pc |
Crosshead sukudireba 50mm 70mm | Kowane 1 pc |
Mataki na 8-10 | 1 pc |
Mataki na 12-14 | 2 pc |
Kaifi hanci | 1 pc |
Kebul na ƙasa | 1 pc |
Kebul na sigina | 1 pc |
Igiyar wutar lantarki | 1 pc |
Rubber hula | 20 pc |
Aluminum foil jakar | 2 guda |
Allura biyu | 25 guda |
Disk | 1 pc |
Kebul na sadarwa | 1 pc |
Gas block | 1 pc |