GDCR1000C Gwajin Jeri na Mataki mara lamba
GDCR1000C, GDCR1000D mara lamba gwajin lokaci ne babban ci gaba a cikin al'ada al'ada tsarin gane jeri tsari.Gano jeri na al'ada shine cire sandar haɗin waya na wayoyi uku, haɗa dandali guda uku ko gwajin alluran mita jerin lokaci zuwa layukan wuta mara ƙarfi guda uku, yayin da GDCR1000C da GDCR1000D sun ɗauki pincers ma'aunin shigar da ba lamba ba.Za'a iya gano jeri na lokaci ta hanyar babu buƙatar cire wayar kuma ba tare da taɓa wayar wutar lantarki mara ƙarfi ba, kai tsaye danne maɗaɗɗen maɗaukaki masu ƙarfi uku masu ƙarfi a jikin fata mai rufewa na wayar wuta mai mataki uku bi da bi.A lokaci guda, ana iya samun nunin acousto-optic na ingantaccen ko yanayin yanayin juzu'i na jerin lokaci na samar da wutar lantarki mai kashi uku.Akwai ƙaƙƙarfan maganadisu huɗu a bayan kayan aikin, waɗanda za a iya haɗa su zuwa akwatin rarraba don amfani.
GDCR1000C, GDCR1000D mara lamba lokaci gwajin yana da ayyuka na looping dubawa, sauki ikon dubawa, da'irar warwarewa wuri, breakpoint wuri, line kiyayewa da sauransu.
GDCR1000C, GDCR1000D mai gano lokaci mara lamba yana da sauri, dacewa kuma mai sauƙin nunawa a kallo, yana inganta amincin gwajin filin, yadda ya kamata yana kare amincin sirri na masu aiki, da haɓaka yawan aiki!Kayan aiki ne na aminci don jerin lokutan samar da wutar lantarki na matakai uku, gano mota da kiyaye layi.
GDCR1000C & GDCR1000D:
Samfura | Gwada wayana wajediamita |
Saukewa: GDCR1000C | ku 1.6mm~ku 16mm |
Saukewa: GDCR1000D | mm10 ku~mm40 ku |
Aiki | Phas check(ingantaccen lokaci, juzu'i na baya, lokacin ɓacewa), duban layi kai tsaye, wurin karyewa, kiyaye layin |
Tushen wutan lantarki | DC 3V 2 sashin alkaline bushe cell (LR6),ci gabaamfani lokaci na game da 70 hours |
Kewayon rayuwa | AC 70 ~ 1000V, 45 ~ 65Hz (cigaba da shigar da igiyar igiyar ruwa) |
Gwada girman waya | Na wajediamita ø1.6mm~ku 16mm or ø10mm~ø40mm(na zaɓi) |
LED nuni | [tabbataccelokaci] Fitilolin gano lokaci 4 suna kunna agogon hannu bi da bi; [relokaci aya]4gano lokacifitilukunna agogo a jere. [layi mai rai] L1, L2 da L3fitulun kunnawaa cikin kewayon saitin wutar lantarki; [bacewar lokaci] L1 ko L2 ko L3 ba a kunne. [budekewaye] Fitilar L1 ko L2 ko L3 basa kunne. |
Buzzing | [tabbataccen lokaci] kayan aiki yana fitar da ɗan gajeren lokaci; [reAyar aya] Na'urar tana fitar da dogayen sautuka. |
Alamar baturi | Alamar WUTA tana haskakawa bayan kunnawa;KYAUTA BATTER yana haskakawa lokacin da wutar lantarki ta gaza |
Magnetism | Akwai maganadisu huɗu da aka haɗe zuwa bayan kayan aikin, waɗanda aka haɗa zuwa akwatin rarraba kuma suna iya tsayayya da ingancin 800g. |
Kashe | Bayan kamar mintuna 5, kayan aikin yana rufe ta atomatik. |
Girma | L 70mm* H 75mm* W30mm |
Cfitilar waya tsawon | 0.6m ku |
Wtakwas | Kimanin g 200 (ciki har da baturi) |
Wyanayin kora | -10℃~55℃<80%rh |
Syanayin ajiya | -20 ℃~60℃;<90% rh |
Ma'auni max.ƙarfin lantarki | AC 1000V |
Dielectric ƙarfi | 5.4kV rms |
Mgatari.rated iko | 300mVA |
Standards | Saukewa: EN61010-1:2001, Saukewa: EN61010-031:2002, ajin gurbacewa2, CAT Ⅲ (600V), wuce gona da iri6000V |
Dauke harka | 1pc |
Baturi (LR6) | 2pcs |
Jerin kaya | 1 kwafi |
Jagorar mai amfani | 1 kwafi |
Rahoton gwajin masana'anta | 1 kwafi |