GDCR3000B Digital Resistance Gwajin

GDCR3000B Digital Resistance Gwajin

Takaitaccen Bayani:

GDCR3000B Resistance Duniya/Mai gwajin juriya na ƙasa an tsara shi na musamman don auna juriyar ƙasa, juriyar ƙasa, ƙarfin ƙasa da ƙarfin AC.An karɓi sabuwar fasahar sarrafa dijital da ƙananan ƙira, don auna juriyar ƙasa ta sandar sanda 4, 3-pole ko 2-pole.

 


Cikakken Bayani

Tags samfurin

Janar bayani

GDCR3000B Resistance Duniya/Mai gwajin juriya na ƙasa an tsara shi na musamman don auna juriyar ƙasa, juriyar ƙasa, ƙarfin ƙasa da ƙarfin AC.An karɓi sabuwar fasahar sarrafa dijital da ƙananan ƙira, don auna juriyar ƙasa ta sandar sanda 4, 3-pole ko 2-pole.FFT (Fourier transform) fasaha, AFC (ikon sarrafa mitar atomatik) kuma yana samuwa, tare da kyakkyawan ikon tsangwama da kuma ikon daidaitawa ga yanayin, don tabbatar da daidaitattun daidaito, babban kwanciyar hankali da aminci.Ana amfani da shi sosai don auna wutar lantarki, sadarwa, ilimin yanayi, filin mai, gini, kariyar walƙiya, kayan lantarki na masana'antu.

GDCR3000B ya ƙunshi na'ura mai watsa shiri, software na saka idanu, igiyoyi na gwaji, sandar ƙasa mai taimako, kebul na sadarwa da sauransu.Babban nunin LCD na na'ura mai masaukin baki yana tare da hasken baya shuɗi da jadawali mai nuni wanda za'a iya gani a sarari.A lokaci guda yana iya adana bayanan 300, gane tambayar tarihi da ayyukan saka idanu na kan layi ta hanyar software na saka idanu, nuni mai ƙarfi, alamar ƙararrawa, tare da ayyukan karantawa, dubawa, adanawa, bayar da rahoto da buga bayanan tarihi.

Ƙayyadaddun bayanai

1. Matsayin Matsayi da Yanayin Aiki

  Daidaitaccen Yanayin Yanayin Aiki Magana
Yanayin yanayi 23℃±1 -10℃~40 ----
Danshi na Muhalli 40%60% 80% ----
Aiki Voltage 9V±0.1V 9V±1.5V ----
Resistance Duniya na taimako 100Ω 30k kuΩ rC,rP
Tsangwama ƙarfin lantarki ---- 20V ----
Tsangwama halin yanzu ---- 2A ----
Nisan Electrode na gwajin R a5d a5d ----
Electrode nisa naρgwadawa a20h ku a20h ku ----

2. Gabaɗaya Bayani

Ayyuka 2-sandi / 3-sandi / 4-sandiMa'aunin juriya na duniya,kasa resistivity,duniya ƙarfin lantarki, wutar lantarki ACaunawa.
Tushen wutan lantarki Farashin DC9V(Zn-Mn busasshen baturi R14S 1.5V 6 guda,Ci gabalokacin jiran aiki300awanni)
Rage Juriya ta Duniya: 0.00Ω30.00kΩ
Resistivity na ƙasa: 0.00Ωm9000km
Wutar lantarki: 0V-600V
Nau'in aunawa 4- iyaka,3-Pole, 2-pole juriya na duniya.
Hanyoyin Aunawa Juriya ta duniya: An ƙididdige hanyar canza sandar sanda na yanzu.Gwajin Curent Max.20mA
Resistivity na ƙasa: Hanyar sanduna 4 (Hanyar Wenner).
Wutar lantarki ta Duniya: Matsakaici mai daidaitawa[P (S) - ES tashar jiragen ruwa]
Yawan Gwaji 128Hz/111Hz/105Hz/94Hz(AFC)
Gwajin Gajerewar Da'irar Yanzu AC 20mA max
Buɗe Wutar Gwajin Wuta AC 40V max
Gwajin Ƙarfin Wutar Lantarki Sine Wave
Range na Electrodes Distance Ana iya saitawa1m-100m
Canjin Matsayi Juriya ta Duniya: 0.00Ω-30.00kΩ Canjin atomatiking.
Resistivity na ƙasa: 0.00Ωm-9000kΩm Canjin atomatiking.
Hasken baya Blue-allon baya
Nuni Model 4 dijital LCD nuni, Blue-allon baya
Hasken Nuni Filashin alamar LED yayin gwaji, LCD ƙidaya ƙasa nuni
Girman LCD 128mm*75mm
Nuni LCD 124mm*67mm
Girma 215mm*190*95mm
Daidaitaccen Jagoran Gwaji Jimlar jagora 4: 1* Ja20m, 1* Baki20m, 1* Ruwa10m, 1* Kore10m
Sauƙaƙan Jagoran Gwaji 2 jagora: 1* Ja 1.6m,1* Bakar 1.6m
Auxiliary Ground Electrodes guda 4:φ10 mm×150mm
Lokacin Aunawa Zuwa wutar lantarki na ƙasa: kusan sau 3 / s
Juriyar ƙasa, juriya na ƙasa: kusan 5 seconds/lokaci
Lokacin Aunawa Fiye da sau 5000 (gajerun gwajin da'ira, gwada sau 1, tsayawa 30 seconds sannan a gwada)
Wutar lantarki Don gwada ƙasa da AC 600V
tashar sadarwa Kebul na kebul, ana iya loda bayanan da aka haddace zuwa PC don adanawa da bugawa.
Jagoran Sadarwa USB,1.5m* 1 guda
Adana Bayanai 300 group,"MEMajiya nuna,"CIKAKKEN” icon don nuna ajiya ya cika
Riƙe Data Ayyukan riƙon bayanai: nunin gunkin "HOLD".
Karatun Bayanai Ayyukan karanta bayanai: nunin alamar "KARANTA".
Nuni mai wuce gona da iri Wuce aikin ma'aunin kewayon ambaliya: nunin gunkin "OL".
Gwajin Tsangwama Gano siginar tsangwama ta atomatik, wkazatsangwama ƙarfin lantarkiya wuce5V,akwai "HURUWA” alamar kararrawa
Gwajin ƙasa na taimako 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP <50kΩ)
Ayyukan ƙararrawa Lokacin aunawa ƙima ya wuce ƙimar saitin ƙararrawa, akwaisautiƙararrawa
Wutar Batir Lokacin da ƙarfin baturi ya ragu zuwa kusan 7.5V, alamar ƙarancin ƙarfin baturi" zai nuna, tunatarwa gacaji
Amfanin Wuta Tsaya tukuna:game da20mA (kashe hasken baya)
Hasken bayaku: 45mA ku(Kashe hasken baya 25mA)
Aunawa: kamar 100mA (kashe hasken baya)
Nauyi Jimlar nauyi tare da jaka: 4.5kg
Mai gwadawa: 950g (ciki har da baturi)
Gwajin Wayoyi: 1560g
Sandar ƙasa mai taimakoshafi: 935g (4PCS)
Yanayin Aiki & Humidity -10 ℃-40 ℃, kasa da 80% rh
Yanayin ajiya & zafi -20 ℃-60 ℃, kasa da 70% rh
Kariya fiye da kima Aunawa ƙasa juriya: tsakanin kowane musaya naC (H) - E,P (S) - ES, AC 280V/3 seconds
Juriya na Insulation Ƙarshe20MΩ (tsakanin kewaye da kewaye shi ne 500V)
Jurewa Voltage AC 3700V/rms (Tsakanin kewaye da kewaye)
Features na Electromagnetic IEC61326 (EMC)
Nau'in Kariya Saukewa: IEC61010-1III 300V, CAT IV 150V, ƙazanta digiri2);
Saukewa: IEC61010-031; IEC 61557-1Juriya ta Duniya);
IEC 61557-5Resistivity na ƙasa); JJG 366-2004

3. Kuskuren asali da aiki a ƙarƙashin daidaitaccen yanayin

Abubuwa Kewayon aunawa Daidaito Ƙaddamarwa
Juriya ta Duniya (R) 0.00Ω30.00Ω ± 2%rdg± 3dgt 0.01Ω
30.0Ω300.0Ω ± 2%rdg± 3dgt 0.1Ω
300Ω3000Ω ± 2%rdg± 3dgt
3.00kΩ30.00kΩ ± 4%rdg± 3dgt 10Ω
Ƙarƙashin ƙasa (ρ)
 
0.00Ωm99.99m Dangane da daidaiton R(ρ=2πaR
ku: 1m-100m;
π= 3.14)
0.01 m
100.0 m999.9m 0.1 m
1000Ωm9999m 1 m
10.00km99.99km 10 m
100.0km999.9km 100Ωm
1000 kΩm9000km 1 km
Wutar lantarki ta duniya AC 0.0600V ±2%rdg±3 dgt 0.1V

Bayani:1. ƙarin kuskure: ≤± 3% rdg ± 5dgt a ƙarƙashin rC max ko rP max.(rC max: 4kΩ+100R<50kΩ, rP max: 4kΩ+100R<50kΩ)
2. ƙarin kuskure: ≤ ± 5% rdg ± 5dgt karkashin 5V tsangwama ƙarfin lantarki