GDCY-20B 20kV Mai gwada Wutar Lantarki (Nau'i na asali)
GDCY-20B Programmable Atomatik Impulse Voltage Tester yana dogara ne akan TB/T 2653, GB/T 17627, GB/T 16927, GB14048, GB7251, GB/T 16935, IEC 61730, GB4706, GB3048 da dai sauransu. bukatun.Ana amfani dashi galibi don aikin aminci (aikin dielectric) gano ƙananan na'urorin lantarki na lantarki, manyan na'urori masu ƙarfi da ƙarancin wutar lantarki, makamashin hasken rana, mita wutar lantarki, relays, masu kariya, da sauransu. Za'a iya sarrafa fitar da kuzari ta kwamfuta, da gwajin gwajin. za a iya buga rahoto da kuma samar da shi.
●Manual/atomatik/yanayin shirye-shirye: Yanayin jagora yana daidaita ƙarfin ƙarfin kuzari da hannu ta hanyar daidaita ƙulli;Yanayin atomatik yana daidaita wutar lantarki ta atomatik ta tsarin;Yanayin shirye-shirye yana amfani da kwamfuta don sarrafa wutar lantarki ta atomatik.
●Yanayin atomatik da yanayin shirye-shirye suna da tsarin wutar lantarki akai-akai na atomatik, wanda zai iya sarrafa ƙarfin fitarwa daidai daidai kuma lokacin tazara bai shafe shi ba.
●Ayyukan sarrafawa na shirye-shirye yana ba da hanyar sadarwa 485 da ka'idar sarrafa shirin.Za a iya saita tsarin gwaji na shirye-shirye bisa ga buƙata.Ana iya sarrafa wutar lantarki mai ƙarfi da sigogi daban-daban (mai iya haifar da faɗakarwa) ta kwamfuta ko cibiyar sadarwar da za a iya sarrafawa.
●Ta hanyar software na sarrafa tsarin kwamfuta, ana iya gane gwajin haɗin batch, kamar sau 2KV3, sau 4KV3, sau 6KV3, -2KV3, -4KV3 sau, -6KV3, da dai sauransu. Matsakaicin ƙungiyoyin 50 na gwajin haɗin gwiwa za a iya gane su, kuma Sakamakon gwajin kamar lokutan rushewa da rashin ƙarfi ana iya mayar da su zuwa kwamfutar.Kwamfuta na iya nuna sakamakon ra'ayoyin da aka yi a hoto don sanya hukunci ya fi fahimta.
●Ana iya buga rahoton gwajin ta kwamfuta, kuma ana iya nuna bayanan gwajin kamar ƙimar kololuwa, adadin kuzari da lokacin tazara.
●Ayyukan hukumci na atomatik na sakamakon gwaji na iya yin hukunci ta atomatik ko gwajin ya cancanta ko a'a bisa ga girman da matakin rage ƙarfin halin da ake samu yayin gwajin.
●Yana ba da ƙa'idar mai raba ra'ayi don oscilloscope don bin diddigin nau'in igiyar wutar lantarki da saka idanu kan ƙarfin fitarwa.
●Nunin LCD 128*64, yana nuna wutar lantarki na DC, ƙarfin motsa jiki, lokacin tazara, da adadin kuzari.
●Maɓallin taɓawa, sarrafa PC, panel na Ingilishi da menu na shirin suna samuwa.
●Polarity mai kyau da mara kyau an tsara shi ta tsarin dual na ingantaccen tushen wutar lantarki mai inganci da madaidaicin babban ƙarfin wutar lantarki.Abubuwan da aka fitar sun fi karko, ƙarfin lantarki ya fi girma kuma ingancin ya fi girma.
●Asalin cikakken tsarin daidaitawa, cikakken daidaiton kewayon ya fi kyau.
●Madaidaicin hanyoyin daidaita ma'auni da aka gina a ciki, ana iya gyara kuskuren a kowane lokaci.
●DC da ingiza fitar da dual.
●Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwararren Ƙwaƙwa tọn na Ɗauka ) yayi: 20kV (4kV-12kV), daidaito: + 3%;
Saitin kai tsaye na kewayon ƙarfin wutar lantarki a cikin yanayin atomatik da yanayin shirye-shirye: 4kV-20kV;
Matakin Wutar Lantarki: 1V;
●Ƙarfin wutar lantarki na ƙwanƙwasa: lokacin gaban lokaci 1.2μs ± 30%;
igiyar ruwa rabin lokaci 50μs ± 20%;
●Hukunce-hukuncen yankewa: leakage halin yanzu: 30mA-1200mA za a iya saita;
ƙarfin lantarki attenuation: 0-99% za a iya saita;
●Lokacin tazarar: 1-9999S;
●Yawan motsawa: 1-9999 / ci gaba da ci gaba mara iyaka;
●Polarity: Tabbatacce/Bari/Mai kyau da mara kyau saiti;
●Girma: 450mm*380*240mm;
●Nauyin: game da 12 kg;
●Taimakon Tsarin Tsawo na zaɓi: WinXP Win7.
Gwajin Wutar Lantarki na Buga: 1 yanki
Manyan igiyoyin gwaji masu ƙarfi da ƙarancin wuta: 1 saiti
Kebul na sadarwa na 485-USB Converter: 1 yanki
DB9 Serial tsawo na USB: 1 yanki
Software na tsarin kulawa na asali: 1 saiti