●Cikakken aiki kuma zai iya gamsar da kowane nau'in CT (kariyar CT, aunawa CT, TP) buƙatun gwajin, kamar gwajin halayyar haɓaka, juzu'i, juriya na iska, juriya na biyu, nauyi na biyu, kuskuren rabo, bambancin kusurwa da dai sauransu Har ila yau ana iya amfani da su. don gwada tashin hankali halayyar, juya rabo, polarity, sakandare iska juriya, rabo kuskure, angular bambanci da dai sauransu na kowane irin PT.
●Tabbatar da filin CT baya buƙatar daidaitattun masu canji na yanzu, injector na yanzu, bankin lodi, mai sarrafa wutar lantarki da manyan igiyoyi na yanzu.Ana amfani da na'urorin gwaji masu sauƙi da aiki don tabbatar da tabbatar da taswirar ta yanzu, wanda ke rage ƙarfin aiki sosai da inganta ingantaccen aiki, kuma yana sauƙaƙe tantancewar filin.
●Daidai auna kuskuren rabo da bambance-bambancen kusurwa, matsakaicin kuskuren da aka yarda da kuskuren rabo shine ± 0.05%, kuma matsakaicin kuskuren izini na bambancin kusurwa shine ± 2min.Yana iya auna matakin 0.2S mai canzawa na yanzu, kuma kewayon ma'aunin rabo shine 1 ~ 40000.
●Dangane da ingantacciyar hanyar juyawa ta mitar don gwada CT/PT ƙarfin lantarki-halayen halayen halayen yanzu da 10% kuskure, matsakaicin ƙarfin AC na 180V da AC na yanzu na 12Arms (36A peak) na iya fitowa, amma yana iya magance gwajin CT. na alamar gwiwa har zuwa 60KV.
●Gwajin gwaji ta atomatik CT/PT sigogi kamar ƙarfin ƙarfin gwiwa / na yanzu, 5% da 10% kuskuren kuskure, ƙimar ƙayyadaddun daidaito (ALF), Factor aminci (FS), matsakaicin lokaci na biyu (Ts), Magnetic Remanence Coefficient (Kr), cikakken kuma unsaturated inductance.
●Gwajin ya dace da nau'ikan ma'auni daban-daban kamar GB1208 (IEC60044-1), GB16847 (IEC60044-6), da GB1207, kuma ana zaɓar matakan gwaji ta atomatik gwargwadon nau'i da matakin na'urar.
●Gwajin yana da sauƙi kuma mai dacewa.Juriya na CT DC, tashin hankali, rabo da polarity ana iya kammala su ta maɓalli ɗaya.Bayan gwajin nauyi, duk sauran gwaje-gwajen CT suna ɗaukar yanayin wayoyi iri ɗaya.
●5.7-inch mai hoto mai jujjuyawar LCD, bayyane a sarari a cikin rana.
●An yi aiki tare da linzamin kwamfuta mai juyawa, aikin yana da sauƙi, sauri da dacewa, kuma mai sauƙin ganewa.
●Wurin da aka gina a ciki, yana buga rahoton gwajin da aka samar ta atomatik.
●Ana iya fitar da sakamakon gwajin ta U disk, kuma ana iya haɓaka shirin tare da diski U, wanda ya dace da sauri.
●Ajiye bayanan rukunoni 1000 kuma ba a rasa bayan wutan lantarki.
●An sanye shi da software na bincike na baya don sauƙaƙe ajiya, juyawa da nazarin rahotannin gwaji, kuma ana iya amfani da shi don kwatanta, hukunci da kimanta bayanan gwaji.
●Sauƙin ɗauka, nauyin na'urar <10kg.