GDHL-200A (GDHL-100A) Sabbin Micro-Ohmmeter
GDHL-200A (GDHL-100A) Micro-Ohmmeter ne yadu amfani don auna madauki juriya da lamba juriya ga weld gidajen abinci, igiyoyi, da daban-daban HV sauya a cikin wutar lantarki masana'antu.Yana amfani da tsarin gwajin fasaha na fasaha "Smart-Quick", wanda aka ba da haƙƙin mallaka na software, da fasahar gano ci-gaba.
●Ɗauki madaidaicin madaidaicin wutar lantarki na yanzu, yanayin haɓaka ta atomatik ba tare da daidaitawar hannu ba, gwajin yana da sauri kuma daidai.
●Yi amfani da hanyar waya ta tasha huɗu, yadda ya kamata ta kawar da tsangwama ta hanyar gwajin juriyar kebul.
●Faɗin kewayon, babban daidaito, kewayon ma'aunin juriya ya kai 99mΩ.
●200A, max.lokacin gwaji na iya isa 1 ~ 999s, wanda ke saduwa da aikace-aikacen kan layi daban-daban.
●Babban fitarwa na yanzu na dogon lokaci, ƙone fim ɗin oxide mai canzawa, yana sa ma'aunin ya zama ainihin gaske.
●Tare da ginannen daidaitaccen resistor, bincikar kai na ainihi akan yanayin wayoyi na ciki da na waje don haɓaka amincin gwaji.
●Nuna juriya, halin yanzu, ƙarfin lantarki, lokaci, matsayi da saurin bayanai akan allo ɗaya, ƙirar ƙirar aikin ɗan adam, tsarin aiki mai sauƙi da sauƙin amfani.
●Tsayayyen fitarwa na halin yanzu tare da ginshiƙai masu yawa na igiyoyin fitarwa, kuma kewayon gwajin juriya yana da faɗi.
●Dogon lokacin aiki kuma yana da cikakkiyar ayyukan kariya kamar buɗaɗɗen kariya da kariya mai zafi.
●4.7 inch babban allo LCD nuni, tare da babban haske, mai iya karantawa a cikin hasken rana mai ƙarfi.
●Gina firinta na thermal, mai sauƙin buga bayanai.
●Ma'ajiyar bayanai 1000.
●Nau'in Turai yana ɗaukar saurin haɗin gwiwa da ƙirar kulle, babban farfajiyar lamba da ƙarfin kwarara mai ƙarfi.
●Haɗin tsarin daidaitawar chassis, masu amfani za su iya haɗa kayan aiki da kayan haɗi masu alaƙa cikin sauƙi.
●Gane fakitin gabaɗaya da ɗauka, don masu amfani su sami ƙarin annashuwa.
●Ƙaƙwalwar ƙira na nau'in ɗagawa da ƙaddamarwa da tsarin haɗuwa na nau'in kwarangwal sun dace don dubawa da kulawa.
●Tsarin da aka haɗa na dukkanin injin yana watsar da damuwa;shayar da girgizawa da maganin buffer yana tabbatar da amincin kayan aiki.
●Bututun iskar da ke jujjuyawa mai siffa mai nau'in walƙiya, haɓaka ƙarfin watsawar zafi, haɓaka rayuwar sabis sosai.
●Ƙananan ƙarami, nauyi mai sauƙi, bai wuce 5kg ba, wanda ya dace sosai don amfani da shafin.
●An sanye shi da kebul na USB ko aikin haɗin haɗin Bluetooth, ana iya haɗa mai masaukin tare da PC ko kwamfutar hannu, wayar hannu, da dai sauransu ta hanyar waya ko mara waya don sarrafa na'urar da samar da rahoton gwaji ta hanyar kwamfuta ko APP.(na zaɓi)
●Shirya ƙaramin shirin, yanki na shigarwa da tsayi zai iya ƙididdige ƙididdigewa ta atomatik, ana iya la'akari da kayan gudanarwa bisa ga ma'auni na ƙasa.
Tushen wutan lantarki | AC220V± 10%, 50Hz |
Matakai na yanzu | 50A, 100A, 150A, 200A, wasu an keɓance su |
Kewayon aunawa | μΩ-99999μΩ; 50A: 1μΩ-99999μΩ; 100A: 1μΩ-50000μΩ 150A: 1μΩ-33000μΩ; 200A: 1μΩ-25000μΩ |
Daidaito | ± (karatun *0.5%+0.1uΩ) |
Ƙaddamarwa | 0.01 ku |
Digital nuni na juriya | 6 1/2 lamba |
Fitar wutar lantarki na madogarar yanzu | ≤5V(10V na zaɓi) |
Lokacin aunawa | Ana iya saita lokutan gwaji da yawa. |
Amfanin wutar lantarki | ≤1000W (≤500W) |
Adana bayanai | 1000 sets |
Yi amfani da yanayi | -20 ℃ ~ 40 ℃, ≤80% RH (ba condensing) |
Nauyi | <5kg |
Babban naúrar | 1 saiti |
200A gwajina USB (ja, baki) | 1 saiti |
Igiyar wutar lantarki | 1 pc |
Gzagaye na USB | 1 pc |
Built-in misali resistor | 1 pc |
Mai amfani's jagora | 1 kwafi |
Katin garanti | 1 kwafi |
Plissafin lissafi | 1 kwafi |
Rahoton gwajin masana'anta | 1 kwafi |