GDHX-9700 Mai gano lokaci
GDHX-9700 Fase Detector an fi amfani dashi a cikin layin wutar lantarki, lokaci, da daidaita tsarin lokaci a cikin tashar, tare da manyan ayyuka ciki har da binciken lantarki, daidaitawar lokaci da ma'aunin tsarin lokaci.Yana amfani da garkuwa biyu da sabbin da'irori na dijital, tare da tsangwama mai ƙarfi, an daidaita shi da ka'idodin EMC, dacewa da yanayi daban-daban na kutse na lantarki.
Babban siginar lokacin auna gubar za a watsa kai tsaye bayan jiyya, wayar hannu za ta karɓa kuma ta yi kwatancen lokaci, ƙayyade sakamakon bayan gano lokaci, bambancin kusurwa na lokaci na ainihi da vector.Yana amfani da fasahar watsawa mara waya, aminci kuma abin dogaro, sauri, kuma daidai, dacewa don amfani a matakan ƙarfin lantarki daban-daban (10V-500KV).Lokacin duba tsarin grid, zai iya gano daidai lokacin dangi na jagora daban-daban don layin da aka haɗa kashi uku, ba tare da wani haɗin lantarki tsakanin abubuwan ma'auni biyu ba, wanda ke sa aikace-aikacen na'urar aunawa sosai kuma mai aminci.
●Wutar lantarki: 10V ~ 500KV, ana amfani da shi don nau'ikan irin ƙarfin lantarki daban-daban.
●Daidaito: gajeriyar nisa: kuskure ≤± 3°;nesa mai nisa: kuskure ≤±3°.
●Yawan samfur: sau 10/daƙiƙa.
●Saitin kwanan wata da lokaci, daidaita kwanan wata da lokaci, mai sauƙi ga masu amfani don lilo, duba bayanan tarihi.
●Saitin hasken baya: kullum a kunne, yawanci a kashe, mai amfani-bayyananne a cikin 0 ~ 999s.
●Rufewa ta atomatik: taba, an ayyana mai amfani a cikin mintuna 0 ~ 999.
●A cikin lokaci: ≤20° (mai amfani da aka ayyana idan matakin lokaci yana tsakanin 0-90°, tsoho 20°)
●Out-lokaci:> 20° (mai amfani da aka ayyana idan matakin lokaci yana tsakanin 0-90°, tsoho 20°)
●Ayyukan daidaitawa a kan wurin: ana iya aiwatar da daidaitawa a kan waya akan wayar da aka gwada don tabbatar da daidaiton kusurwar lokaci.
●Ƙirar yanayi da yawa, mafi kyawun aiki, mafi aminci, mafi dacewa.
●Mutum-injuna na musamman na injiniya, aiki mai sauƙi.
●Ƙirar eriya ta FCC, sigina mai ƙarfi, sauƙin shiga bango, kofofi, da shinge.
●Karewa sau biyu, tsangwama mai ƙarfi, cikin cikakken yarda da ka'idodin EMC.
●Charts da nunin bayanai, sauƙin karantawa, tare da aikin nunin kwanan wata da lokaci.
●Ma'auni mai inganci: nuni ta siginar murya-optic.
●Ma'aunin ƙididdigewa: nuni na ainihin lokaci na bambancin kusurwar lokaci, kuskure ≤5°.
●Bincika jerin matakai: ingantaccen tsarin lokaci, jerin mara kyau (120°, 240°).
●Karkashin sabis na lokacin tauraron dan adam na GPS, nisan ganowa tsakanin mai gano Xa da Ya shine ≥500km.
●Ƙimar ajiyar bayanai na ƙungiyoyi 2000.Yana iya yin tambaya da samun dama ga bayanan tarihi.
●Tsawon misali rufi sanda ne 4m, da kuma m ƙarfin lantarki sa na rufi sandar ne ≤ 220kV.
Wutar lantarki | 10V ~ 500kV |
Tushen wutan lantarki | Hnaúrar da aka riƙe: babban ƙarfin baturin lithium |
Xa & Ya ganowa:AA girman baturi alkaline (1.5V) 3pcs | |
Watsawa mara waya | Nisa na gani 150m |
A cikin lokaci | ≤20° (mai amfani da aka ayyana idan matakin lokaci yana tsakanin 0-90°) |
Fitar lokaci | >20° (an ayyana mai amfani idan matakin lokaci yana tsakanin 0-90°) |
Nuna daidaito | Ma'aunin ƙididdiga ≤5° |
Ƙimar kusurwar lokaci | 1 ° |
Ma'aunin jerin lokaci | An ƙayyade jerin lokaci ta agogon agogo 120°/maki 240° |
Kewayon lokacin tauraron dan adam | 2 ~ 30 mintuna |
Nunawa | Nau'in LCD mai inganci, bayyananne a cikin hasken rana. |
Yanayin aiki | -35 ~ + 50 ℃ |
Yanayin ajiya | -40 ~ + 55 ℃ |
Dangi zafi | ≤95%RH, condensing |
Naúrar hannun hannu | 0.31 kg |
Mai gano Xa | 0.16 kg |
Mai gano Ya | 0.16 kg |