GDJB-6000D Tsarin Gwajin Kariya Mai Kyau
GDJB-6000D sanye take da babban aikin ƙara ƙarfin aiki kuma ya dogara akan dandamalin PowerPC+X86 mai ƙarfi.Yana ɗaukar ƙira na yau da kullun kuma yana da ayyuka masu ƙarfi, babban madaidaici, ƙaramin girma da fasalulluka masu nauyi.Yana iya gwada aiki da aikin naúrar haɗawa, na'urar kariya ta gudun ba da sanda, aunawa da na'urar sarrafawa, tashoshi masu hankali da sauransu. Ya dace sosai ga masana'antar wutar lantarki, tashoshin sadarwa, rukunin bincike na kimiyya daban-daban da masana'antun kera kayan aiki.
●Smart Test Module
Ana goyan bayan gyara samfurin gwaji na fasaha.Za a iya ƙara abubuwan gwaji ba da gangan ba yayin aikin gwaji kuma a adana su azaman fayilolin aikin gwajin da za a sake amfani da su don haɓaka ingancin gwajin a matakin ƙarshe na dubawa da kawarwa.
●Gwaji ta atomatik
Tare da kariyar yanar gizo da kariyar dijital aikin gwaji ta atomatik, duk abubuwan gwaji na na'urar kariya guda ɗaya za a iya kammala su da maɓalli ɗaya.
●Hanyoyin dubawa da yawa
Yana goyan bayan amplitude, lokaci, mita, impedance, vector, jeri, da wutar lantarki ana aiwatar da su ta manual ko gwajin atomatik, kuma yana goyan bayan gwajin canjin atomatik bisa ga hanyar gradation, zamewa da kira.
●Nuni mai hoto ta zahiri
Goyan bayan aikin nunin hoto mai hoto, kwararar bayanai a bayyane take.
●Aika da karɓar saƙonni a lokaci guda
Goyon bayan IEC61850-9-1, IEC61850-9-2 da GOOSE na gani na saƙon dijital.Ana iya aika siginar GOOSE da karɓa da kanta, kuma tana iya aikawa da karɓa ta hanyar haɗin Intanet na gani tare da IEC 61850-9-2.
●FT3/Extended FT3
Taimakawa FT3, fadada FT3 da fitarwar saƙon DL/T 282, da goyan bayan 2M/4M/6M/8M/10M baud rate UART encoding da 5M/10M/20M Manchester encoding.
●Gwajin mara kyau
Tare da aikin rashin daidaituwa na saƙon analog, yana iya kwaikwayi rashin daidaituwa cikin inganci, aika jitter mita, jinkirin jinkiri, asarar fakiti, fita daga mataki, tsallen lamba na lamba, yanayin kulawa, canjin kama-da-wane na jihar da sauran gwaje-gwaje.
●sake kunnawa kuskure
Yana goyan bayan simintin kuskure da aikin sake kunna bayanan tsarin COMTRADE.
●Sabis na MMS
Tare da aikin karantawa da rubutu na MMS, na iya karantawa da rubuta saitunan kayan aikin IED masu hankali da sauran bayanan sanyi.
●Daidaita lokaci da bada lokaci
Tare da aikin faɗakarwa na aiki tare, tallafi don samun kai tsaye zuwa eriyar GPS/BD don aiki tare na lokaci, kuma yana goyan bayan IRIG-B, PPS da PTP 1588 yanayin lokaci kuma yana iya tallafawa fitarwa na waje IRIG-B, PPS da PTP 1588 lokacin bada sigina.
●Shigarwar binary mai wuyar lamba da fitarwar binary
Adadin shigarwar yana aiki da lambobi masu karɓuwa, kuma nau'in shigarwa da ƙarfin shigarwa ana gane su ta atomatik.Tashoshin sun keɓance daga juna, kuma polarity yana jujjuya haɗin kai tare da faɗakarwa.
●Karɓar saƙo da bincike
Tare da aikin karɓar saƙon da aikin bincike, ana iya buɗe saƙon da aka karɓa tare da ZHNPA don bincike ko fitarwa.
●Yanayin fiber guda ɗaya
Tashar tashar gani tana goyan bayan watsa-fiber guda ɗaya da liyafar fiber guda ɗaya kuma tana goyan bayan gwajin ƙarfin gani.
●Analog ƙananan sigina
An sanye shi da ƙananan siginar siginar analog, goyon bayan 12 hanyar analog ƙananan shigarwar sigina, na iya auna -7V ~ 7V AC ƙarfin lantarki, goyan bayan 12 hanyar ƙananan siginar siginar analog, kuma yana iya fitarwa -7V ~ 7V AC ƙarfin lantarki.
●Taɓa aiki
An sanye shi da babban nuni mai girman inci 10.4 wanda ke goyan bayan aikin taɓawa.
●Haɗin mara waya
Samar da aikin gwajin nesa, tare da tsarin WiFi, mai sauƙin amfani.
IEC 61850 tashar sadarwa | |
Aiki | Duk wani sanyi na IEC 61850 9-1 / 9-2 SMV watsa, karɓa ko watsa GOOSE da liyafar |
Nau'in mu'amala | LC Tantancewar tashar jiragen ruwa |
Yawan | 8 nau'i-nau'i, 6 nau'i-nau'i * 100M masu daidaitawa, 2 nau'i-nau'i * 100/1000M masu dacewa |
Tsawon igiyar ruwa | 1310 nm |
IEC 60044 tashar sadarwa | |
Aiki | GB/T 20840.8, DL/T 282, Q/GDW441 karba da aikawa |
Nau'in mu'amala | ST |
Yawan | 6 * aikawa da dubawa, 2* karɓar dubawa |
Mataki | |
Rage | 0 ~ 360° |
Daidaito | ±0.1° |
Ƙaddamarwa | 0.1° |
Yawanci | |
Rage | 0 ~ 1000 Hz |
Daidaito | <±0.001Hz (0 ~ 65Hz) <±0.01Hz (65 ~ 450Hz) <±0.02Hz (450 ~ 1000Hz) |
Ƙaddamarwa | 0.001 Hz |
Lokaci | |
Rage | 10ms ~ 9999.999s |
Ƙaddamarwa | 1ms |
Shigar da lamba ta binary | |
Yawan | 8 nau'i-nau'i, Ana iya haɗa su zuwasadarwar banza kuma tare da yuwuwar lamba (0 ~ 250V) |
Fitowar lamba ta binary | |
Yawan | 6 nau'i-nau'i, nau'i-nau'i 2 suna fitar da sauri |
Karya iya aiki | DC250V / 0.5A |
Lokacin amsawa | <100 mu |
Aiki tare | |
Nau'in mu'amala | GPS/BD ANT;IRIG-B/PPS siginar gani;IRIG-B/PPS siginar lantarki;IEEE 1588 |
Yawan | 1*GPS/BD ANT; 2 * IRIG-B / PPS siginar gani: 1 * aiki tare lokaci, 1 * bayarwa lokaci; 2 nau'i-nau'i * IRIG-B / PPS siginar lantarki: 1 nau'i-nau'i * aiki tare da lokaci, 1 nau'i-nau'i * bada lokaci; 1 nau'i-nau'i* IEEE 1588 |
Haɗin mara waya | |
Nau'in mu'amala | WIFI |
Haɗin waya | |
Nau'in mu'amala | 100M Lan tashar jiragen ruwa, RJ45 |
Yawan | 2 guda |
Analog ƙaramar shigar da sigina | |
Nau'in mu'amala | Filogi na jirgin sama, wutar lantarki AC |
Yawan | tashar 12 |
Analog ƙaramar fitowar sigina | |
Nau'in mu'amala | Filogi na jirgin sama, wutar lantarki AC |
Yawan | tashar 12 |
Tushen wutan lantarki | |
Wutar lantarki | AC/DC 220V, Izinin karkatacce: -20% ~ 15% |
Yawanci | 47 ~ 65 Hz |
Kebul na USB | |
Yawan | 2 guda |
Yanayin aiki | |
Yanayin aiki | -10℃~50℃ |
Danshi | ≤95%,rashin natsuwa |
Wasu | |
Nauyi | 5.5 kg |
Girma | 146×390×212mm (L×W×H) |
Yanar gizo ta yanar gizo | RJ45 |
Nunawa | 10.4 inch gaskiya launi LCD tabawa |