GDKC-15 Series Breaker Analyzer
Babban ƙarfin wutar lantarki yana ɗaya daga cikin mahimman kayan sarrafawa a cikin tsarin wutar lantarki.Ana amfani da jerin GDKC-15 don gwada halaye masu ƙarfi na mai watsewar wutar lantarki mai ƙarfi.Yana da sauƙi don aiki, tare da babban daidaito.
GDKC-15A | Saukewa: GDKC-15B | Saukewa: GDKC-15C | GDKC-15D | GDKC-15E | GDKC-15F | Saukewa: GDKC-15G | GDKC-15H | |
Karfe lamba | 12 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
Juriya na rufewa | 6 | 6 | 6 | 6 | 6 | 6 | 6 | |
Alamar hoto | 3 | 3 | 3 | 3 | 6 | |||
Ƙarshen ƙasa mai ƙarewa biyu | 3 | 3 | 3 | 6 | ||||
Juriya mai ƙarfi (Resissor wanda aka riga aka shigar) | 1 | 1 | 3 | 3 | 3 | 3 | 6 | |
Juriya a tsaye | 1 | 1 | 3 | 3 | 3 | 3 | 6 | |
Juriya na ƙasa | 3 | 6 |
●Ya dace da gwajin injina na kowane nau'in SF6 masu sauyawa, kayan haɗin GIS, maɓalli mai motsi da mai sauya mai.
●Ƙarfin ƙarfin hana tsangwama.Ana iya gwada shi cikin sauƙi kuma a auna shi daidai a cikin tashar 500KV.
●Accelerometer (na zaɓi), firikwensin layi, firikwensin juyawa, mai sauƙin shigarwa da sauƙi.
●Duk bayanan gwajin sifa na injina da kuma taswirar madaidaicin madaidaicin ana samun su bayan an kunna canjin sau ɗaya.
●Ajiye bayanan gwajin filin da ginanniyar agogon lokaci na gaske, wanda ya dace don adanawa da adana kwanan wata da lokacin gwajin.
●Tare da allon LCD na 10.1inch, nuna duk bayanai da taswira, tare da hasken baya, daidaitawar LCD da kashe ƙwaƙwalwar ajiya.
●Ayyukan menu na abokantaka, mai sauƙin amfani.Tare da ginanniyar firinta don buga duk sakamakon bayanai da sauri.
●An sanye shi da software na sarrafa bayanai, wanda za'a iya sarrafa shi akan layi tare da PC, tare da fayil ɗin tsarin WORD.Za a iya fitar da sakamakon gwajin zuwa kowane nau'in na'urar buga rahotannin gwaji don yin gwajin filin a na'ura mai kwakwalwa.
●Buɗe da zaɓin zaɓin sauri da ƙayyadaddun aikin mai amfani da aka saita bisa ga buƙatu, wanda ya dace da ma'aunin saurin kowane nau'in sauyawa.
●Lokaci:
Lambobin sadarwa 12 na buɗe (kusa) lokacin buɗewa
A cikin aiki tare lokaci
Aiki tare na mataki-zuwa-lokaci
●Maikewa:
CO, OC, lokacin COC,
Lokacin buɗewa na farko, lokacin rufewa na farko, lokacin kusa na biyu, lokacin buɗewa, lokacin matattu, babu lokacin yanzu.
●Juncing:
Rufe lokacin billa, lokuta, tsari da tsarin kalaman kowane lambobi.
Buɗe maimaita girman kowace lamba.
Gudun gudu: saurin tuntuɓar buɗewa kawai kuma rufewa kawai, matsakaicin saurin gudu, yanayin yanayin tafiyar lokaci.
Tafiya: jimlar tafiya, buɗaɗɗen nisa, kan tafiya, tafiya mai wuce gona da iri, girman koma baya.
Yanzu: Buɗe/rufe halin yanzu, zane na halin yanzu na maɗaurin buɗaɗɗe/kusa.
Wutar lantarki mai aiki: ginanniyar DC0 ~ 300V/20A dijital, tushen wutar lantarki mai daidaitacce, kammala gwajin aikin LV ta atomatik na mai watsewar kewayawa da auna ƙimar ƙarfin lantarki na mai watsewa.
Juriya na rufewa: lokacin da aka riga aka yi simintin, sigar riga-kafin-fitch da ƙimar juriya na rufewar resistor na lambobin sadarwa 6.(na zaɓi)
Alamar hoto: buɗewa, lokacin rufewa da sigar motsi mai ƙarfi na Siemens graphite lamba sauyawa tare da lambobi 3 ko 6. (na zaɓi)
Ƙarshen ƙasa mai ƙarewa sau biyu: ƙarƙashin 3 ko 6-way dual-port grounding, zai iya auna daidai lokacin buɗewa da rufewa.(na zaɓi)
Juriya a tsaye: 1 * 100A ma'aunin juriya na lamba.
Juriya mai ƙarfi (Resissor Pre-saka): 1*100A canjin yanayin juriya mai ƙarfi yayin aikin mai watse kewaye.
●Muhallin Amfani
Ƙarfin shigarwa: 220V± 10%, 50Hz±10%, Hawan iska: 86-106kpa
Zazzabi: -10-40 ℃ Danshi: ≤80% RH
●Ayyukan Tsaro
Resistance Insulation>2MΩ
Ƙarfin Dielectric: Shell na iya jure wa mitar ƙarfin wutar lantarki 1.5kV a cikin minti 1 ba tare da walƙiya da harbi ba.
●Ma'auni na asali
Lokaci: Range 20000.0ms, ƙuduri 0.01ms, kuskure 0.5%
Juriya na rufewa: kewayon 10kΩ, min.ƙuduri 1Ω, kuskure 0.5% (na zaɓi)
Alamar hoto: kewayon 200ms, min.ƙuduri 0.1ms, kuskure 0.5% (na zaɓi)
Ƙarshen ƙarewa biyu: kewayon 200ms, min.ƙuduri 0.1ms, kuskure 0.5% (na zaɓi)
Juriya a tsaye: kewayon 1uΩ~10mΩ, min.ƙuduri 0.01μΩ, kuskure 0.5%
Juriya mai ƙarfi: kewayon 10mΩ, min.ƙuduri 1μΩ, kuskure 0.5%
Gwajin halin yanzu: DC 50A, 100A(3 lokaci da aka auna a lokaci guda)
Gudun gudu: Rage 20.00m/s ƙuduri 0.01m/s kuskure 0.5%
Tafiya:
Nau'ukan | Rage | Ƙaddamarwa | Kuskure |
Mai karyawa | 50.0mm | 0.1mm |
0.5% |
Saukewa: SF6 | 300.0mm |
1 mm | |
Maimai jujjuyawa | 600.0mm |
A halin yanzu: kewayon 20.00A, ƙuduri 0.01A
Ƙarfin fitarwa: DC 0-300V dijital daidaitacce / 20A (aiki nan take), ƙuduri 1V.
Girma: kimanin 360mm (L)* 280mm (W)* 300mm (H)
Nauyi: kusan 10kg
Babbanunit tare da kwamfutar hannu 10.1-inch | 1 pc |
Kayan haɗi | 1 pc |
Caja don kwamfutar hannu | 1 pc |
Adaftar daidaitattun Amurka | 2 guda |
Rotary saurin firikwensin | 1 pc |
firikwensin saurin linzamin kwamfuta50mm ku | 1 pc |
Kebul na haɗin siginar sauri (5-core garkuwa waya) | 1 pc |
Kebul na buɗewa da rufewa(3-core sheathed USB) | 1 pc |
Matsala na wajeganowakebul (ja/baki, 2-core) | 1 pc |
Kebul na ƙasa | 1 pc |
Tuntuɓi gwajin kebul(4-core sheathed USB) | 1pc |
Cna'urar tsawaita gwajin kantact (5M, rawaya, kore da ja kowane yanki guda, baki 3pcs) | 6inji mai kwakwalwa |
Short na USB (baƙar fata 0.5m,2m baki) | 2 guda |
Igiyar wutar lantarki | 1 pc |
Universal Joint da magnet tushe | 1 saita |
Na'urorin haɗi na ƙayyadaddun ƙayyadaddun shigarwa | 1 saiti |
Gwada shirye-shiryen bidiyo da thimbles | 18 guda |
Ccontact juriya gwajin na USB(5M) | 1 pc |
Buga takarda | 2 rowa |
Kebul na USB | 1 pc |
Jagorar mai amfani | 1 pc |
Rahoton gwajin masana'anta | 1 pc |