GDP-311IR SF6 Gwajin Tsaftar Gas (Hanyar IR)
GDP-311IR SF6 mai gwada tsabtace gas shine kayan aiki mai ɗaukar hoto don gwajin tsabtace iskar gas na SF6 akan rukunin yanar gizon mu.Ƙa'idar infrared SF6 na'urar firikwensin gwajin gas ɗin da Kamfanin Sensor na Turai ya ƙera ana amfani da shi don gwada tsabtar iskar SF6.Tare da ƙwararrun kwakwalwan kwamfuta na hardware da ingantattun algorithms na software na STMicroelectronics, mun samar da sabon ƙarni na SF6 mai nazarin tsabtace gas.
●Tsabtace tsaftar kayan aikin gas na SF6 don wutar lantarki
●Gwajin ingancin Gas Silinda SF6
●Gwajin inganci na SF6 gas don farfadowa da sake amfani da su
●High tsarki gas masana'antu
●Masana'antar Semiconductor bushewar iskar gas
●Bincike da amfani da ci gaba
●Kulawar ɗaki/bushewar gida
●Ana shigo da na'urori masu inganci masu inganci tare da aikin daidaitawa, tabbatar da kwanciyar hankali da amincin bayanan gano tsarki cikin shekara.
●Duk hanyar gas tare da babban ƙirar kayan polymer, yana tabbatar da cewa babu wani abin rataye bangon ruwa kuma yana ba da garantin saurin gwajin.
●Ana amfani da bawul ɗin da ba shi da mai ba da bakin karfe don tabbatar da daidaiton ƙimar da aka auna.
●Algorithms na software na ci gaba suna haɓaka daidaiton gwajin na'urori masu auna firikwensin.
●Haɗin tsarin daidaitawar chassis, masu amfani za su iya haɗa kayan aiki da kayan haɗi masu alaƙa cikin sauƙi.Ana ɗaukar fakitin gabaɗaya, wanda ke sa mai amfani ya sami kwanciyar hankali.
●Gwajin farawa, babu buƙatar oscillate.
●Canjin yanayin zafi da gyaran bayanan matsa lamba.
●Fasahar kwamfuta mai ban mamaki.
●Babban ƙarfin baturin lithium mai ƙarfi, gane AC da wadatar wutar lantarki dual DC.Ba a buƙatar ƙarfin AC na kan-site.Batirin Lithium yana ci gaba da aiki sama da awanni 8 ba tare da buƙatar wutar lantarki ta waje ba.
●Anti-electromagnetic tsangwama ƙirar kewaye don tabbatar da amincin samfur.
●Ƙwaƙwalwar ƙima mai girma, wanda zai iya gane saiti 1000 na ayyukan ajiyar bayanai.
●Daidaitaccen ma'aunin tsabta shine 0.5% a cikin cikakken kewayon.Ana iya amfani da shi zuwa ma'aunin iskar gas mai girma SF6 da 70% abun ciki na SF6 gas.
●Mafi kyawun wurin gwajin gwaji yana nuna cewa mai amfani zai iya daidaita kwararar iskar gas cikin hankali da sauri.Rage lokacin gwaji.
●An ƙera mashigar iska tare da ƙaramin haɗin haɗin kai, kuma hanyar iskar da za a gwada ba za ta zube ba lokacin da aka katse hanyar iska.
●Yana iya faɗaɗa sadarwar USB, sadarwar serial, tsarin sadarwar mara waya, da kuma gane ayyukan sadarwa da bugu na babbar kwamfuta.(na zaɓi)
●Ana iya amfani da aikin gyaran hanyar iskar gas don tsarkake bututun gwajin kafin aikin gwajin filin, wanda ya rage lokacin gwajin.(na zaɓi)
●Kayan aikin yana da aikin dawo da iskar gas don dawo da iskar ma'aunin sulfur hexafluoride.Kare yanayin yanayi.(na zaɓi)
Hanyar aunawa | Ƙa'idar Auna Infrared (NDIR jerin firikwensin) |
Yanayin aiki | -20 ℃ ~ + 60 ℃ |
Ma'auni kewayon | 0 ~ 100% SF6 |
Lokacin amsawa | [90%] 60s |
Daidaito | ± 0.5% FS |
Maimaituwa | ± 0.5% |
Ƙaddamarwa | 0.01% |
Naúrar nuni | % |
Yawan kwararar iskar gas | 400 ~ 600ml/min |
Nuna adadin kwarara | 0 ~ 1000mL shigo da dijital mai gudana |
Sauƙaƙan iskar gas | ≤1MPa |
Yanayin yanayi | 90% RH |
Tasirin ƙimar ƙimar | Babu tasirin matsa lamba da kwarara |
Tushen wutan lantarki | AC 220V± 10%, 50Hz / DC Baturi a ciki na iya aiki aƙalla 8 hours |
Girma | 395*295*155mm |
Nauyi | kusan 2kg. |