GDSL-D Jerin Dijital na Farko na Gwaji na Yanzu
●DL/T 596-2005 "Tsarin Gwaji don Kayan Aikin Lantarki"
●GB1094.1-GB1094.6-96 "matakin kariyar Shell"
●GB2900 "Tsarin Lantarki"
●GB/T16927.1~2-1997 "Fasahar Gwajin Babban Wuta"
●GB4793-1984 "Bukatun Tsaro don Kayan Aunawar Lantarki"
●GB191 "Alamar Ma'ajiya da Sufuri"
●GB / T.311-1997 "Tsarki da daidaitawa na watsa wutar lantarki mai girma da kayan aikin canji"
●Yin amfani da jan ƙarfe mai ƙarfi kamar yadda ake fitar da wutar lantarki, fuskar sadarwar tana da girma kuma ƙarfin kwarara yana da ƙarfi.
●Farantin aluminum da aka goge tare da sabon tsari, mai sauƙi kuma mai ɗaukar ido, mai jure lalacewa da ƙazantawa.
●Bakin filastik na fesa duk karfe da kuma sanannen sautin launin toka na duniya yana da ƙarfi kuma abin dogaro, yana tabbatar da amincin kayan aiki.
●Yin amfani da simintin birki na duniya yana sa motsi da gyare-gyare mafi sauƙi da dacewa.
●Bututun iska mai siffa mai siffa don haɓaka ɗumamar zafi da tsawaita rayuwar sabis.
●Duk injin ɗin yana da ƙarami kuma yana da haske a nauyi, wanda ya dace sosai don amfani da filin.
●Yana da aikin kariyar sifili don hana tasirin babban halin yanzu daga haifar da lalacewa ga samfurin.Ba za a iya farawa lokacin da ba a matsayin sifili ba.
●Ayyukan zaɓin tasiri, lokacin da aka yi gwajin saurin hutu mai saurin kewayawa, ana iya yanke aikin kariyar sifili kuma ƙimar halin yanzu da ake buƙata na iya fitowa kai tsaye.
●Yanayin fitarwa na yanzu: ƙimar RMS ta gaskiya tana ci gaba da daidaitawa.
●Abubuwan da ake fitarwa a halin yanzu daidaitaccen igiyar igiyar ruwa ce, kuma ƙimar karkatarwar igiyoyin ba ta wuce 5%.
●Wutar lantarki da nuni na yanzu suna ɗaukasabon babban madaidaicin nunin dijital na LED
●Girman kewayon da za'a iya canzawa don haɓaka kyawun nuni don ƙarin ingantaccen karatu.
●Za'a iya kunna wutar lantarki da wutar lantarki mai sarrafawa don nunawa don kallo cikin sauƙi.
●An tsara ƙarfin kayan aiki don ɗan gajeren lokaci, aiki na wucin gadi a cikin minti 5.
●Don gwajin tsari, rufe minti 10 bayan mintuna 2.5 na ci gaba da aiki.
●Yana iya auna lokacin aikin na yanzu na ɓangaren da aka gwada kuma yayi rikodin lokacin aikin kullewa tare.(na zaɓi)
●Tsawon lokacin da aka auna: 0.001S~999.999S Resolution 1ms, kuskuren aunawa: 0.005% kewayo ± 2digs.(na zaɓi)
●Ana iya nuna ƙimar gwajin firamare na halin yanzu da na biyu kai tsaye don sauƙaƙe gwajin rabon canji.(na zaɓi)
●Matsayi na biyu na yanzu 0 ~ 5A ƙuduri 1mA (na zaɓi)
●Idan zafin zafin jiki ya tashi (minti 30 - awanni 24) ya kamata a keɓance shi bisa ga tashin zafin aiki na dogon lokaci.(na zaɓi)
●Za a iya keɓance matakai uku tare da haɓaka daidaita ma'auni (na zaɓi)
●Za a iya keɓance AC da DC riser (na zaɓi)
Samfura | Ƙarfin fitarwa(kVA) | Fitar halin yanzu(A) | Tushen wutan lantarki(V) | Buɗe wutar lantarki(V) | Power lokaci | Alama | |
GDSL-D-500 | 3 | 500 | 220 | 6 | LN | Integrated | |
GDSL-D-1000 | 6 | 1000 | 220 | 6 | LN | Integrated | |
Saukewa: GDSL-D-1500 | 9 | 1500 | 220 | 6 | LN | Integrated | |
GDSL-D-2000 | 12 | 2000 | 220 ko 380 | 6 | LN | AB | Integrated ko hadewa |
Saukewa: GDSL-D-2500 | 15 | 2500 | 220 ko 380 | 6 | LN | AB | Integrated ko hadewa |
GDSL-D-3000 | 18 | 3000 | 220 ko 380 | 6 | AB | Integrated ko hadewa | |
GDSL-D-4000 | 24 | 4000 | 380 | 6 | AB | hade | |
GDSL-D-5000 | 30 | 5000 | 380 | 6 | AB | hade | |
GDSL-D-6000 | 36 | 6000 | 380 | 6 | AB | hade | |
Saukewa: GDSL-D-8000 | 48 | 8000 | 380 | 6 | AB | hade | |
GDSL-D-10000 | 60 | 10000 | 380 | 6 | AB | hade | |
Saukewa: GDSL-D-12000 | 72 | 12000 | 380 | 6 | AB | hade | |
Saukewa: GDSL-D-15000 | 90 | 15000 | 380 | 6 | AB | hade | |
Za a iya keɓancewa saboda buƙatun abokin ciniki na musamman |
Saitin gwajin allura na farko na yanzu | guda 1 |
Igiyar wutar lantarki | guda 1 |
Wayar Kasa | guda 1 |
Babban Layin Yanzu (misali 2m) | 2 guda |
Takaddun shaida | 1 kwafi |
Manual | 1 kwafi |
Jerin kaya | 1 kwafi |
Rahoton Gwaji | 1 kwafi |