GDUD-PTM Ultrasonic Flaw Detector For Electrical Power Tower
●TFT allon launi na gaskiya.
●Yin amfani da manyan fasahar tsarin dijital da aka haɗa, alamun aikin lantarki na kayan aikin an ƙirƙira su da ƙera su bisa ma'aunin EN 12668.1-2000.
●Batir lithium polymer mai girma da aminci da fasahar sarrafa wutar lantarki, ƙararrawa ta atomatik da kariya.Za a iya saita na'urar ajiyar allo ta atomatik don sanya kayan aiki su kasance masu ƙarfi da ƙarfi da tsayi, kuma don tabbatar da ci gaba da gano aibi.
●Software na aikace-aikacen da ke haɗa ayyukan sarrafawa masu hankali da ƙarfi, ƙirar mai amfani da karanta kai tsaye da yanayin aiki, ko yanayin aiki na maɓalli ɗaya na dijital.
●Tashar saiti mai girman ƙarfin gano sigogi, dacewa ga masu amfani don aiki akan abubuwan gano daban-daban.Ƙaƙƙarfan ma'ajiya na bayanai da ƙarfin bincike na tsaye, haɗe tare da kwanan gano aibi na ainihin lokaci da saƙon agogon aiki tare da rikodi, suna sa ganowa cikin sauƙi.
●Tare da m nisa square kalaman bugun jini janareta, da m ƙarfin lantarki watsa don samun m watsa ikon.Saitunan damping masu dumbin yawa suna ba da damar bincike don dacewa da dacewa da kayan aiki.
●Kyakkyawan halayen amplifier da halayen bandeji.Amplifier yana da daidaito na 0.1dB, tare da fadi-band da kunkuntar hanyoyin aiki, kuma ana iya auna mitar bincike a ainihin lokacin, wanda ke ba da mafi kyawun sakamakon ganowa lokacin da mai amfani ya gano kayan daban-daban.
●Tare da kewayon ganowa mai faɗi (har zuwa mita 6) da ƙudurin sigina mai ƙarfi, min.0.1mm m daidaitacce kewayon.Zaɓi kewayon da ya dace da bincike mai dacewa don kyakkyawan ƙudurin filin kusa.
●Kyakkyawan kayan aiki mai sauri-sauri na ainihi aiki da ingantaccen ƙira na aikin sarrafa mitar bugun jini don saduwa da mafi kyawun sakamako don nau'in kristal daban-daban da nisan ganowa.Nunin echo yana da tasiri mai ƙarfi kuma ba shi da ƙura.
●Canje-canje ta atomatik don bincike da farfajiyar lanƙwasa, wanda ke haɓaka haɗawa tsakanin binciken da abin gwaji kuma yana tabbatar da daidaito.
●Tare da aikin lanƙwan nisa-amplitude (DAC), sauti mai sarrafa shirye-shirye da sarrafa ƙararrawa haske.
●Tare da kebul na USB mai sauri, sauƙin sadarwa tare da kwamfutar, tallafawa ayyukan sarrafa kwamfuta da shirye-shiryen kan layi.
●Hasken aluminum gami da hannu wanda ke riƙe da gidaje, wanda ke da kyakkyawan aikin hana tsangwama.Haɗu da aji kariyar IP65.
Watsawa/karba
Wutar lantarki mai watsawa | 600V |
Mitar samfur | 100MHz (Max.) |
Mitar maimaita bugun jini | 60Hz |
Daidaitawar impedance | 50Ω/500Ω |
Yanayin aiki | Mai watsa kai da karɓa/ Mai watsawa ɗaya da karɓa ɗaya/ Shiga |
Ƙaddamarwa | ≥36dB(5N14) |
Matsakaicin ƙarar wutar lantarki | ≤ |
Ƙara/gane
Tashin hankali | ≥60dB (zurfin 200mm, Φ2Flat kasa rami) |
Riba | 0~110dB, mataki 0dB/0.1dB/1dB/2dB/6dB domin zabi |
Daidaiton Amplifier | ± 1dB |
Kuskuren layi na tsaye | ≤3% |
Riba ta atomatik | 10% -90% |
Rage Rage | ≥35dB |
Tushen lokaci
Kewayon ganowa | 10-6000mm, 0.1,1 da 10mm mataki atomatik saitin |
Kuskuren layi na kwance | ≤0.1) |
Sautin sauti | 1000-16000m/s, mataki shine 1m/s |
Sifili diyya (jinkirin bincike) | 0 - 500.0 |
Nuni kwanon rufi | 0-1000.0mm;0.1, 1mm mataki atomatik saitin |
Lankwasa
DAC lankwasa | Nisa-amplitude curve(DAC), 2~10pcs reference point |
4 ƙarin madaidaitan dB masu lanƙwasa |
Sarrafa sigina
Danne sigina | 0-90%, madaidaiciya |
Ƙofar ganowa (1 guda) | Matsayin farawa / faɗi / tsayi ci gaba da daidaitawa |
Ƙararrawa mai kyau/mara kyau a cikin ƙofar | |
Fitowa (sauti da ƙararrawar haske). | |
Zaɓin ma'aunin sigina a cikin ƙofar | |
Yanayin aunawa | Hanyar sauti/tazarar kwance/zurfin nunin lissafin ainihin lokacin |
TOF (lokacin tashi) ma'aunin nunin lissafin lokacin gaske | |
Nuni mai ƙarfi na karkatar da hanyar sauti | |
Lissafin ma'aunin karatu a tsaye | |
Ƙididdigar tunani da matsayi na zaɓi |
Aikin gano aibu
Tashoshi | ƙungiyoyi 20 |
Adana | 500 echo sakonni |
Nunawa | Cikakkun daskare/ daskarewar magana |
Lankwasa ambulaf | Nuni rikodin ambulan kololuwa |
Agogon lokacin gaske | Bibiyar kwanan wata/lokaci, daidaitaccen lokacin agogo |
Interface | USB tashar jiragen ruwa, goyon bayan kwamfuta sadarwa da kuma management |
Nunawa
Nunawa | Babban haske, nunin TFT launi na gaskiya, inci 5.7 |
Yawanci | NTSC (60Hz) |
Tsari da yanayin amfani
Baturi | Baturin lithium polymer, lokacin aiki ≥ 10 hours |
Girma da nauyi | 210mmx165mmx50mm,1.8kg (tare da baturi) |
Yanayin yanayi | -5 ℃ - 60 ℃ |
Dangi zafi | 20-90% RH |
Babban Unit | guda 1 |
Adaftar wutar lantarki | guda 1 |
HF anti-EMI bincike na USB | 2 guda |
Kebul na USB | guda 1 |
Bincike | 2 guda |
Module | guda 1 |
CD | guda 1 |
Jagorar mai amfani | 1 kwafi |
Rahoton Gwajin Masana'antu | 1 kwafi |