GDYM-3F Mai ɗaukar nauyi Multi-aikin Makamashi Calibrator
●Daidaita lissafin duk sigogi da nuni akan ke dubawa sun haɗa da cikakken igiyar ruwa, igiyar ruwa na asali da igiyar jituwa kamar yadda lokaci guda ke nuna U, I, P, Q, VA, kusurwar lokaci game da cikakken igiyar ruwa da igiyar ruwa mai mahimmanci gami da haɗin haɗin gwiwa na I, U.P PF, harmonic kalaman PF.
●Hanyar dubawa ta haɗa da nau'ikan nau'ikan hanyoyin 7 na cikakken aiki mai ƙarfi, cikakken ƙarfin amsawar kalaman, cikakken bayyana raƙuman raƙuman ruwa, ƙaƙƙarfan raƙuman raƙuman ruwa, ƙarfin amsawa na asali, bayyananniyar raƙuman ruwa da jituwa, wanda zai iya bincika daidaiton ƙarfin aiki na cikakken mitar kalaman, asali na asali. Mita, mitar igiyar ruwa masu jituwa da daidaiton ƙarfin amsawa na cikakken igiyar igiyar ruwa da mita masu jituwa, kuma na iya bincika ainihin daidaiton mitar makamashin lantarki.
●Zaɓaɓɓen sabani ɗaya ko fiye da jituwa don ƙididdige mahaɗin jituwa na U, I, P, Q, VA da kasonsa da kuma igiyar jituwa mai aiki da ƙarfin lantarki.
●A lokaci guda ɓangaren bincike guda ɗaya da ƙimar ƙimar kowane lokaci U, I, P, Q, VA na igiyoyin jituwa na zamani guda uku kuma suna nuna sau 51 + PH / - PH da kashi na mahimmancin kalaman don tantance tasirin tabbatacce da mara kyau na jituwa akan mita.
●Cikakken ƙarfin amsawar kalaman shine jimlar algebraic na ƙarfin amsawa na ainihin igiyar igiyar ruwa da igiyar jituwa ta kowane mai jituwa.Don kauce wa 90 digiri motsi a baya da kuma a cikin hali na jituwa kalaman reactive ikon gwajin kuskure.Za mu iya auna alamar tare da mitar makamashin lantarki wanda za'a iya ganowa kuma zaɓi lambar kowane igiyar jituwa.
●A lokaci guda gwada bugun bugun jini guda biyu da aka gano, kuma akai-akai, yanayin aiki da adadin da aka gano a lokaci guda na iya bambanta gaba ɗaya.
●Yi nauyi sau 2.4, duk ma'aunin ma'auni na iya tabbatar da cewa daidaiton 0.05% kuma ya ba da garantin ma'aunin ma'aunin CT na sakandare na yanzu lokacin da yake 1A.
●Matsakaicin sau 500 na yanzu yana tabbatar da ma'auni, kewayon nuni na yanzu sau 1000, mafi ƙarancin 1mA na farawa na yanzu.A lokaci guda na samar da wutar lantarki mai girma, ana auna na'ura mai mahimmanci, kuma za'a iya gano na'urar ba tare da kaya ba.
●Ayyukan tara makamashi na lantarki na iya auna mitar makamashin lantarki wanda ba ya fitar da bugun bugun jini.
●Nuna zane-zane, na iya gano wayoyi uku na 48 ba daidai ba da wayoyi huɗu na 96 ba daidai ba da kuma CT na giciye na biyu.
●Ɗauki 7 inch 16: 9 darajar masana'antu da allon launi mai faɗi na TFT, kowane sigar aikin kayan aiki kai tsaye ne kuma bayyananne nuni akan allon lokaci guda ba tare da kunna allo ba, ƙyale masu amfani suyi amfani da kallo.
●Kayan aiki na iya yin kwatankwacin nau'ikan wayoyi iri-iri da samun daidaitattun sakamakon wayoyi da daidaitawa a ofis ba tare da samun wutar lantarki ko sigina na yanzu ba.Ana iya amfani da wannan aikin azaman kayan aiki don duba layin horo don inganta ƙwarewar duba layi na ma'aikatan filin.
●Kayan aiki na ciki na iya samar da ainihin siginar 0.05-5A na yanzu kuma an ƙara su cikin matsi na 5A don bincika kuskuren mitar matsa.Yin tunani cikin asusun 5A matsa yana da matsalar canjin kuskure bayan an yi amfani da shi na dogon lokaci.Ba da damar sanin halin da ake ciki na rufewa game da mitar matsa a kowane lokaci, tunatar da ma'aikatan da suka dace akan lokaci don tsabtace muƙamuƙi mai matsawa.Lokacin maye gurbin matsi na 5A, ana iya gyara kuskuren zuwa 0.2.
●Shigar da lambar mita makamashi ta atomatik (aikin zaɓi)
Goyan bayan na'urar daukar hotan takardu da shigar da lambar makamashi ta atomatik.
●Yi amfani da 485 ko infrared shugaban photoelectric don karanta tip mai yawan ayyuka na makamashi, kololuwa, lebur, kwari, jimillar tushe mai aiki da amsawa, karanta akai-akai da lokaci.Goyi bayan ƙa'idodin DL645 na ƙasa, DL645-1997 da DL645-2007.(aikin zaɓi)
●2G faifan lantarki da aka gina a ciki.
●Ana iya sanye shi da firinta mai girman inci 3, mai ƙarfin baturi, kuma kai tsaye yana canza hoton allon launi zuwa baki da fari lokacin bugawa.(na zaɓi)
●Yin amfani da mitar matsa (5A, 100A, 500A, 1000A) kai tsaye don auna ma'auni da kuskuren rabo na ƙaramin wutar lantarki na yanzu.(100A, 500A, 1000A manne na zaɓi ne)
●Nuna wutar lantarki da sifar kalaman na yanzu na lokaci A, B, C.
●Wurin shigar da wutar aiki shine 55V-600V.Matsakaicin matakan shigar da wutar lantarki na yau da kullun uku-uku shine 600V.Maɓallai na masana'antu suna canza haɗin wutar lantarki na birni da ƙarfin lantarki na lokaci uku azaman ƙarfin aiki.
●Duk sigogin da ake buƙatar shigar da su akan rukunin yanar gizon da zazzage bayanan mai amfani na iya fayyace su kyauta.Yana iya saukar da bayanan masu amfani 5000.
●Ana iya ajiye allon na yanzu zuwa U faifai.
●Tare da aikin auna zafin jiki da zafi (buƙatar shigar da zafin jiki da firikwensin zafi).
●Tare da kebul na kebul kuma yana haɗi zuwa kebul na USB don samar da babban sarari don kwafin bayanai.
●Taba allo kuma latsa aikin maɓalli, madannai ta amfani da tsarin ginshiƙin madannai na kwamfuta.Hakanan akwai maballin PC tare da kebul na USB.
●Lokaci tare da injin PC ta hanyar kebul na USB.
●Kwamfutar kwamfutar hannu na iya sarrafa kayan aiki kai tsaye tare da tsarin aiki iri ɗaya kamar kayan aikin.
●Za'a iya amfani da soket ɗin ma'aunin wutar lantarki da maɓallin wutar lantarki don darajar masana'antu a ƙarƙashin 600V (Maɓallin wutar lantarki na yau da kullun shine 250V, wanda aka yi amfani da shi a cikin kewayon sama da 380V, wanda ke da haɗarin aminci).
●Babban tsarin tsaro.Babban soket, soket auna wutar lantarki, shigarwar halin yanzu, shigarwar matsawa na yanzu an keɓe, kuma ƙarfin juriya shine 4kV.
●Kariyar shigar da bugun bugun wutar lantarki.Lokacin shigar da babban ƙarfin lantarki zai fara kariya ta atomatik kuma ya nuna saƙon gaggawa akan kayan aiki, da zarar an gyara kuskuren, danna mahaɗin don sake saita kariyar.
●Matsi na 5A yana da aikin gyara kansa: siginar 5A na yanzu ana ƙirƙira shi a ciki ta kayan aikin da aka ƙara zuwa maƙallan 5A don auna kuskuren mitar matsa.
●Ana amfani da kwakwalwan kwakwalwar ƙananan ƙarfin ARM 5, duk ikon ƙididdigewa ya fi 1GIPS girma, kuma duk sigogi na 51 harmonic da cikakken kalaman ana ƙididdige su a lokaci guda.
●Yin amfani da tsarin aiki na Windows CE tare da balagagge kuma na gaske, aikinsa yana da ƙarfi kuma abin dogaro.
Wutar lantarki | Garanti kewayon kuskure | 25-600V | |||
Fara auna ƙimar | 0.5V | ||||
Ƙimar ƙima | 440V | ||||
Kuskure daidaito | ± 0.05% | ||||
A halin yanzu | Tasha | An ƙididdige shiIe | 5A | ||
Rage | 0.025A-12A | ||||
Matsa | An ƙididdige shiIe | 5A, 100A, 500A,1000A(na zaɓi) | |||
Rage | 0.5% watau-2.4Ie | ||||
Farawa yanzu | 0.02% I | ||||
Kewayon mitar shigarwa | 45-65Hz | ||||
Kuskuren auna mitoci | ± 0.01Hz | ||||
Ma'aunin kusurwa na lokaci | -180°-180° | ||||
Max.Kuskuren kusurwa na mataki | ± 0.1° | ||||
Kashi masu jituwa, ma'aunin wutar lantarki masu jituwa, da lokutan ma'aunin kuzarin wutar lantarki masu jituwa | 2-51sau | ||||
Pulse akai-akai (Lura:Ieana rating halin yanzu) | Ƙananan fitarwa(3 geza) | 5A | 3600P, 36000P, 360000P/kWh (kvarh, kVAh) | ||
wasu | 3600P, 36000P, 360000P * (5/Ie) P/kWh (kwar, kVAh) | ||||
Babban mitar ciki | 5A | 1.8x109P/kWh | |||
Sauran kayan aiki na yanzu | 1.8x109* (5/Ie) P/kWh | ||||
Matsakaicin shigarwar bugun bugun jini | 50kHz | ||||
5Atasha | Babban igiyar ruwa mai cike da igiyar ruwakWh, P, U, I | ± 0.05% | |||
Babban igiyar ruwa mai cike da igiyar ruwa Kvarh, Q, VA, WAH | ± 0.2% | ||||
masu jituwaigiyar ruwaU, I, P, Q, S | ± 0.2% H(H=1+0.01k K=2-51) | ||||
5Amatsa | Babban igiyar ruwa mai cike da igiyar ruwakWh, P, U, I | ± 0.2% | |||
Babban igiyar ruwa mai cike da igiyar ruwa Kvarh, Q, VA, WAH | ± 0.2% | ||||
masu jituwaigiyar ruwaU, I, P, Q, S | ± 0.5% H(H=1+0.01k K=2-51) | ||||
Duba kai na halin yanzu fitarwar keken keke | 0.05A, 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A | ||||
KaidubawaKuskure (bambancin madaidaiciya da kusurwa) | ± 0.1% | ||||
Babban matsi na yanzu | Babban igiyar ruwa mai cike da igiyar ruwakWh, P, U, I | ± 0.5% | |||
Babban igiyar ruwa mai cike da igiyar ruwa Kvarh, Q, VA, WAH | ± 0.5% | ||||
masu jituwaigiyar ruwaU, I, P, Q, S | ± 1.0% H(H=1+0.01k K=2-51) | ||||
Wasu | Ma'aunin rabo | ± 0.5% | |||
Tasirin ƙarfin lantarki | <± 0.01% | ||||
Yawancitasiri | <± 0.01% | ||||
Zazzabitasiri | ± 0.005% / ℃ | ||||
24hours canza kuskure | <± 0.01% | ||||
masu jituwatasiri | <± 0.01% | ||||
Baturi mai caji | 11.1V 3000mAh | ||||
Juriya irin ƙarfin lantarki (Ma'aunin wutar lantarki na yanzu da samar da wuta da ƙananan tashoshi) | 4.0 kV | ||||
Fashewa Mai Saurin Wutar Lantarki | 4.0 kV | ||||
Surge | 4.0kV(Yanayin gama gari),2.0kV(Hanya daban) | ||||
Lokacin jiran aiki bayan farawa | <3minti | ||||
Yanayin yanayi | -25 ℃ - + 45 ℃ | ||||
Dangi zafi | 40% -95% | ||||
Wutar lantarki mai aiki | AC 55V-600V | ||||
Amfanin wutar lantarki | <9W | ||||
Girma | 275mm*196*78mm | ||||
Nauyi | <1.5kg |
1--Allon taɓawa
2--tsari mashaya
3--Share maɓalli
4--Fita (baya).
5--Allon madannai
6-- Canja maɓallin
7--Space key
8--Maɓallin kewayawa/Ok
9--Power soket
10-- Canjin wuta
11--Uku na shigar wutar lantarki soket (ABC)
12-- USB tashar jiragen ruwa
13--RS232 gyara tashar jiragen ruwa
14--Caji soket
15-- Canjin baturi
17--Bakwai core wiring mariƙin ga A lokaci halin yanzu matsa
18--Bakwai ainihin mariƙin wayoyi don matsi na halin yanzu na B
19--Bakwai core wiring mariƙin ga C lokaci halin yanzu matsa
20--Pulse siginar dubawa
21--A lokaci na shigar da shigarwa & fitarwa soket
22--B lokaci shigarwar halin yanzu & soket fitarwa
23--C lokacin shigarwa na yanzu & soket na fitarwa
24--Maganin rataye
Filin calibrator na mita watt awa uku | 1 saiti |
100A clamp Watch | guda 3 |
Matsa zoben gyarawa | guda 1 |
Photoelectric shugaban df307 | guda 1 |
USB faifai (software sarrafa) | guda 1 |
3 zamani ƙarfin lantarki line high irin ƙarfin lantarki (ciki har da matsa da fil) | guda 1 |
Layin zamani na 3 (ciki har da matsawa da saka) | guda 1 |
Layin bugun jini na 3 Phase 1A | guda 1 |
Adafta | guda 1 |
Igiyar wutar lantarki | guda 1 |
madauri | guda 1 |
Akwatin kayan aiki | guda 1 |
Manual samfurin | 1 kwafi |
Takaddun shaida na samfur | 1 kwafi |
Jerin shirya kayan masana'anta | 1 kwafi |
Rahoton gwajin masana'anta | 1 kwafi |