GDYZ-302 Mara waya ta Zinc Oxide Surge Arrester Gwajin
GDYZ-302 Zinc Oxide Arrester Live Tester kayan aiki ne na musamman da ake amfani dashi don gwada aikin wutar lantarki na Zinc Oxide Arrester.Ya dace da gano rayuwa ko kashe wutar lantarki na Zinc Oxide Arrester na matakan ƙarfin lantarki daban-daban, don gano lahani masu haɗari kamar dampness na rufin ciki da tsufa na faranti na bawul a cikin lokaci.
Kayan aiki yana da sauƙi don aiki kuma mai sauƙin amfani.Dukkanin tsarin aunawa ana sarrafa shi ta kwamfuta mai masana'antu.Yana iya auna cikakken halin yanzu, resistive halin yanzu da masu jituwa, ƙarfin magana na mitar wutar lantarki da masu jituwa, ƙarfin aiki da bambancin lokaci.Nuna sifofin raƙuman ruwa na gaskiya na ƙarfin lantarki da na yanzu.Kayan aikin yana amfani da fasaha na nazarin waveform na dijital da hanyoyin hana tsangwama na software kamar nazarin jituwa da tacewa na dijital don sanya sakamakon auna daidai da kwanciyar hankali.Yana iya tantance ainihin abin da ke cikin madaidaicin igiyar ruwa da na uku zuwa na bakwai masu jituwa, kuma yana iya shawo kan tasirin tsangwama tsakanin lokaci.Auna juriya halin yanzu na mai kama lokaci-gefe.
●800 * 480 launi LCD tabawa, babban saurin thermal firinta;zane-zane da nunin rubutu, dubawar fahimta, mai sauƙi ga ma'aikatan filin don aiki da amfani.
●Wayar da siginar PT mara waya ta wuce mita 400, wanda zai iya kaiwa mita 2000 akan buƙata.
●Ya dace da mai kama kai tsaye, mai kashe wutar lantarki ko gwajin dakin gwaje-gwaje.
●Haƙiƙa cimma ma'aunin ƙarfin lantarki na zamani da na uku-uku a lokaci guda, haɓaka ingantaccen aiki;kayan aiki kawai yana da rauni na ciki, ƙarfin lantarki bai wuce 12V ba;Na'urori masu auna firikwensin na yanzu da na lantarki gaba ɗaya sun keɓe, amintattu kuma abin dogaro.
●Hakanan za'a iya auna zub da jini na zinc oxide arrester ba tare da counter ba, wanda gaba ɗaya yana magance matsalar gwajin kama 6 ~ 10KV.
●Yana goyan bayan aiki tare da waya da aiki tare mara waya don samfurin siginar siginar lantarki, kuma yana goyan bayan yanayin mara ƙarfin lantarki don nemo bayanin ƙarfin lantarki ta hanyar lissafin software.
●Tare da babban aiki da manyan ƙarfin batir lithium-ion, ya dace musamman don aikace-aikacen da ba shi da iko.
●Kayan aikin yana ɗaukar dandamali na kayan masarufi da tsarin aiki da aka haɗa, wanda zai iya faɗaɗa aikin kunna sauti da bidiyo da aikin nishaɗin wasa.
●Ana iya kunna na'urar da kashewa a kowane lokaci, wanda ya fi kwanciyar hankali fiye da na'urar da ke kan kwamfutar masana'antu, kuma ba ta da sauƙin faɗuwa da faɗuwa.
●Ana iya fadada ayyukan software kowane lokaci, ko'ina bisa ga buƙatun abokin ciniki.
●An sanye shi da kebul na USB don tallafawa fitar da bayanan U-disk.Ana iya amfani da shi tare da linzamin kwamfuta na USB da keyboard, kuma yana da sauƙin aiki.
●Katin SD mai ƙarfin 4 GB na iya adana babban adadin bayanan gwaji, kuma yana da ayyukan sarrafa bayanai da adanawa.
●Taimakawa software na sarrafa PC, tare da sarrafa bayanan tarihi, nazarin bayanai, buga rahoton da sauran ayyuka.
●Mitar samfur mai sauri, ci-gaba fasahar sarrafa siginar dijital, aikin hana tsangwama mai ƙarfi, daidaiton sakamako mai girma.
●Akwatin da aka haɗe da ƙura, mai hana ruwa da hana lalata injiniyoyin filastik an karɓi akwatin, wanda ƙaramin girmansa ne, haske cikin nauyi da sauƙin ɗauka.
Tushen wutan lantarki | Yana goyan bayan adaftar wutar lantarki ta waje (12V/2A) da baturi na ciki |
Kewayon aunawa | Leakage halin yanzu (ƙimar mafi girma): 0 ~ 10mA (mai yiwuwa) Ƙarfin wutar lantarki (ƙimar mafi girma): 30-100V (mai yiwuwa) |
Daidaiton aunawa | Yanzu: ± 2% karatun ± 1 dijital a cikakken halin yanzu> 100 μA Ƙarfin wutar lantarki: ± 5% karanta +1 dijital a siginar wutar lantarki <30V: Ƙarfin wutar lantarki: Siginar wutar lantarki na nuni> 30V: Yanayin waya: + 2% karatu +1 dijital; Yanayin mara waya: + 5% karatun +1 dijital; |
Sigar aunawa | Cikakkun sigar motsi na yanzu, RMS na asali da ƙimar ƙyalli na yanzu; Babban raƙuman ruwa na RMS na ɓoyayyen ɓangaren juriya na yanzu da RMS na 3, 5 da 7 sau; Ƙimar juriya na halin yanzu kololuwar ƙima: tabbatacce kololuwar Ir + korau kololuwa Ir-; Capacitive halin yanzu muhimmi kalaman, cikakken ƙarfin lantarki, cikakken halin yanzu bambanci kwana bambanci; Wutar lantarki RMS; Amfani da wutar lantarki; |
Hanyar yin samfur na siginar tunani | Aiki tare na Waya: 40m (Maɗaukaki) Haɗin kai mara waya:> 400m (Maɗaukaki) |
Baturi | Lokacin caji: > 6 hours Ci gaba da aiki lokaci: > 4 hours Lokacin aiki:> 8 hours |
Girma | Babban naúrar: 36cm*26cm*14cm Na'urorin haɗibtsayi: 42cm*33cm*20cm |
Nauyi | Babban naúrar: 5.0kg , Akwatin kayan haɗi: 9.0kg |