GDZRS-20B Three Phase DC Winding Resistance Tester

GDZRS-20B Three Phase DC Winding Resistance Tester

Brief Description:

GDZRS-20B Three Phase DC Winding Resistance Tester is a new generation of rapid tester that integrates magnetization method testing, three-phase testing (Yn, Y, △) and degaussing functions. It is an ideal equipment for measuring the DC resistance of large power transformers. The screen adopts a large-screen high-resolution LCD, which is convenient for on-site use. All direct resistance test items can be completed with one connection. The test speed is fast, the accuracy is high, and the measuring range is wide.


Product Detail

Product Tags

Features

• For Yn-type, Y-type and △-type windings, the three-phase measurement method can be used for testing, and the three-phase unbalance rate can be calculated.

• The test power supply has a maximum output current of 20A and a test range of 0~25kΩ, which meets the testing needs of most transformers; it also integrates magnetization and degaussing functions to meet various needs of field tests.

• The test process can automatically calculate the resistance value change rate within 5S, 15S, and 30S, which can assist the tester to judge the stability of the test data and prevent misreading of the data.

• The instrument has multiple protection functions such as back electromotive force protection, wire break protection and power outage protection.

• The instrument is equipped with a thermal printer, which can store 200 pieces of data and supports USB mass storage.

• Industrial-grade 7-inch true-color large-screen display, fresh and simple display style design, full touch plus one-button shuttle operation, creating a comfortable and convenient human-computer interaction experience for you. •

Specifications

Output current

Single phase: 20A, 10A, 5A, 1A, 0.1A, 10mA, <1mA

Three-phase: 10A+10A, 5A+5A, 1A+1A, 0.1A+0.1A

Measuring range

Single phase:

20 A: 0.5mΩ~ 1 Ω

10 A: 1.0mΩ~2 Ω

5 A:10 mΩ~4 Ω

1 A: 0.1Ω~20Ω

0.1A: 2.0Ω~200Ω

10mA: 50Ω~2kΩ

<1mA: 500Ω~25kΩ

Three phases:

10A + 10A: 0.5mΩ ~ 0.8 Ω

5 A + 5 A: 10 mΩ ~ 1.6 Ω

1 A + 1 A: 0.1 Ω ~ 8.0 Ω

0.1A+0.1A: 2.0 Ω ~ 80 Ω

Accuracy

±(reading*0.2%+2 words)

Working power supply

AC220V±10%, 50/60Hz

Operating temperature

-10℃~50℃

Relative humidity

<90%, no condensation

Instrument volume

400*315*223mm

Instrument weight

9kg


  • Previous:
  • Next:

  • Send your message to us:

    Write your message here and send it to us

    Send your message to us:

    Write your message here and send it to us