Ƙarfin lodin Saitin Gwajin Injection na Farko na Yanzu ya dace da kariyar busbar da tabbatar da ma'auni na canji na yanzu, da dai sauransu, kuma yana iya daidaita relays na yanzu da masu sauyawa.Ana amfani da shi musamman don gwada abubuwa kamar kariyar busbar da ma'auni daban-daban na canji na yanzu.Saboda ƙarancin amfani da wutar lantarki, babban ƙarfi mai jujjuya kai da babban ƙarfin maganadisu, mai canzawa yana da babban ƙarfin fitarwa.Amfanin ƙananan girman da nauyin nauyi.
"Abubuwan tuhuma" na babban gwajin janareta na yanzu:
Me yasa amfani da Saitin Gwajin Injection na Farko na Yanzu don auna juriyar mai watsewar kewaye?
GDSL-D Seriese Digital Primary Primary Test Set
1.A cikin gwajin rigakafi da gwajin sauyawa na tsarin samar da wutar lantarki, yawancin kayan aikin lantarki na yanzu suna buƙatar auna daidai juriya na kewaye.Masu watsewar kewayawa sune mahimman kayan lantarki a tsarin wutar lantarki.Ma'aunin GB na ƙasa da ma'auni na masana'antar wutar lantarki DL/T sun ƙayyade ma'aunin juriya na juriya na madaidaicin madauri: yakamata a auna shi ta hanyar digowar wutar lantarki ta DC, kuma halin yanzu bai gaza 100A ba.
2.Juriya na da'irar da'ira na mai watsewar kewayawa ya dogara ne akan juriyar lamba tsakanin ma'amala mai motsi da kuma madaidaiciyar lamba na mai watsewar kewaye.Kasancewar juriya na lamba zai ƙara hasara lokacin da aka kunna mai gudanarwa, ta haka ne ƙara yawan zafin jiki a lamba, kuma ƙimar wannan darajar kai tsaye yana rinjayar ƙarfin ɗaukar nauyi a lokacin aiki na yau da kullum, ta haka yana rinjayar ikon yanke gajere.Yanayin kewaye yana cikin digiri.Sabili da haka, ƙimar juriya na kowane lokaci na na'ura mai ba da hanya tsakanin hanyoyin sadarwa shine mahimman bayanai don shigarwa, sake gyarawa da kuma yarda da ingancin na'urar.
3.A baya an auna juriyar tuntuɓar na'urar ta amfani da gada mai hannu biyu na DC.Duk da haka, lokacin da aka yi amfani da gadar hannu biyu don auna juriya na da'irar da'ira na na'ura mai rarrabawa, tun da halin yanzu ta hanyar ma'aunin gada mai hannu biyu yana da rauni sosai, yana da wuya a sami fim din oxide tare da babban juriya. , kuma yana da wuya a auna ƙimar juriya da yawa, amma fim din oxide yana da sauƙi Yana rushewa a ƙarƙashin babban halin yanzu kuma ba zai hana wucewa na halin yanzu na al'ada ba.Don haka, lokacin amfani da hanyar digowar wutar lantarki na DC don gwaji, kada na yanzu ya zama ƙanƙanta.
4.Akwai hanyoyi da yawa don auna juriyar lamba.Malaman kasashen waje suna ba da shawarar yin amfani da na'urorin ƙididdiga masu ƙarfi don auna juriyar lamba, don auna juriyar lamba ta hanyar sel na lantarki, da auna juriyar lamba ta hanyar jituwa ta uku.Ana amfani da waɗannan hanyoyin don binciken tuntuɓar lantarki a ƙarƙashin yanayin dakin gwaje-gwaje.A aikin injiniya, ana amfani da hanyar ta tasha huɗu don auna juriya na ainihin lambobin sadarwa.
HVHIPOT GDSL-D jerin dijital nuni babban janareta na yanzu (na'urar haɓakawa) kayan aiki ne masu mahimmanci don kowane nau'in rayuwa a cikin lalata lantarki inda ake buƙatar babban halin yanzu.Ana amfani da shi a cikin masana'antar wutar lantarki, tashoshi, masana'antar kera kayan lantarki, binciken kimiyya, da gwaji.Raka'a irin su ɗakuna suna cikin tsarin aiki na ɗan gajeren lokaci ko na ɗan lokaci, wanda ke da halaye na ƙananan girman, nauyi mai sauƙi, kyakkyawan aiki, da amfani da kulawa mai dacewa.An fi amfani da shi don kariyar bas na farko da kuma tabbatar da na'urori masu canzawa daban-daban na yanzu, masu kariyar mota, na'urorin kashe iska, kaset ɗin sauya sheƙa, na'urorin kewayawa, allon kariya, da sauransu.