GDPD-414 Mai Gano Sashe Mai Rarraba Mai Rayuwa



Babban
naúrar
Sensor UHF,
nau'in zagaye,dace da GIS
UHF firikwensin, nau'in rectangle, dacewa da kebul na wutar lantarki, mai canza wuta, mai sauyawa



HFCT, dace da wutar lantarki na USB, transformer
Sensor TEV,
dace da switchgear
Ultrasonic firikwensin, dace da masu canji, switchgear

Hotunan da ke sama don tunani ne kawai.
The GDPD-414 Portable (GDPD-414H Hannu) Mai gano ɓarna na ɓarna yana ɗaukar tsarin gwajin wutar lantarki mai sauri mai hankali (Lamba 1010215 mai laushi, lambar rajistar alamar kasuwanci 14684781 (14684481)).Yana iya daidaita na'urori daban-daban bisa ga samfuran daban-daban da za a gwada.TEV, ultrasonic da HFCT sun dace da gano ɓarna na fitarwa na babban ƙarfin wutan lantarki da majalisar cibiyar sadarwar zobe;Ultrasonic da UHF sun dace don gano GIS;Ultrasonic da HFCT sun dace don gwada kebul na wutar lantarki.Ƙwararren ƙwararrun ƙwararrun tsarin ganewar asali na iya nazarin bayanan gwaji da kuma yin hukunci da makamashin fitarwa da sassa masu yiwuwa.Ana amfani da shi sosai a wutar lantarki da layin dogo.

Ultrasonic da TEV firikwensin (2-in-1)
●Ɗauki jirgin samfurin DSP/FPGA mai sauri, sayan bayanan aiki tare da tashoshi 4.
●Tsarin software: software na bincike bisa tsarin shigar ARM
●Ana iya daidaita tashoshi 6/8/16
●kwamfutar hannu 8.1 inch ko littafin rubutu na Thinkpad azaman zaɓi
●6/8/16 tashoshi za a iya kaga bisa ga abokin ciniki ta daban-daban bukatun.
●Za a iya nuna taswirar PRPS da PRPD, zane-zane na ellipse, taswirar ƙimar fitarwa, taswirar QT, taswirar NT, taswirorin tarawa na PRPD, taswirorin fai-QN na kowane tashar sigina.
● Hanyoyin nuni masu launi uku na ja, rawaya da shuɗi suna nuna tsananin fiɗar sashi.
Abokin ciniki na iya zaɓar na'urori masu auna firikwensin daidai da abubuwan da aka gwada daban-daban:
Sensors | TEV/AE/HFCT | AE/UHF | AE/HFCT |
Abubuwan da aka gwada | HV Swichgear da majalisar hanyar sadarwar Ring |
GIS |
Kebul |
Mai watsa shiri na siginar PD | |
CPU Mitar Aiki | 1.2GHz / 800 MHz |
Tsarin aiki | Tsarin aiki na Linx |
Tashar tashar sadarwa mai waya | LAN cibiyar sadarwa tashar jiragen ruwa |
Mara waya tashar jiragen ruwa | Wi-Fi mara waya da aka gina a ciki (na zaɓi) |
Ƙwaƙwalwar tsarin aiki | 1G / 512M |
Ƙwaƙwalwar ajiya na tsarin | 512M / 256M |
Mitar sayan bayanai | 250MHz / 80MHz |
Tashar ganowa ta Ultrasonic | |
Kewayon aunawa | 0-60mV |
Kewayon gano mita | 20 ~ 200 kHz |
Tashar gano UHF | |
Mitar ganowa | 300 ~ 1800MHz / 300 ~ 1500MHz |
Kewayon aunawa | -80-10dBm |
Kuskure | ± 1dBm |
Ƙaddamarwa | 1 dBm |
tashar gano HFCT | |
Kewayon mitar | 0.5 ~ 100 MHz |
Kuskure | ± 1dB |
Rage Rage | 60dB ku |
Kewayon aunawa | 0-100mV |
Daidaito | 1 dB |
Tashar gano TEV | |
Kewayon mitar | 3 ~ 100 MHz |
Kuskure | ± 1 dB / mV |
Hankali | 0.01mV |
Kewayon aunawa | 0-60dB / mV |
Ƙaddamarwa | 1 dBm / mV |
Baturi | |
Batirin da aka gina a ciki | Baturin lithium, 12V, 4400mAh / baturin lithium, 12V, 2000mAh |
Yi amfani da lokaci | kamar 8 hours / game da 6 hours |
Lokacin caji | Kusan awanni 2 |
Kariyar baturi | Ƙarfin wutar lantarki da kariya na yau da kullum |
Cajin baturi | |
Ƙimar wutar lantarki | 12.6V |
Yin caji na yanzu | 2A |
Yanayin aiki | -20 ℃ - 60 ℃ |
Yanayin aiki | <80% |
GDPD-414H Tashar nunin Hannu (jin masana'antu) | |
CPU | Intel Quad Core Atom Z3735F |
GPU | Intel HD Graphic (Gen7) |
Filasha | 32GB |
RAM | 2GB |
Tsarin aiki | Windows10 |
Nunawa | 8.1 inch 1280 × 800 IPS allon |
Hanyoyin sadarwa na sadarwa | Wifi da Bluetooth |
Baturi | 3.7V 8500mAH polymer lithium ion baturi |
Kwamfutar tafi-da-gidanka ta Thinkpad ko kwamfutar hannu | |
Girman | |
Girman ƙarar na'ura / Girman saye na PD | 395mm*295mm*105mm/240mm*165*55mm |
PD masauki nauyi | 3kg / 0.65kg |
Girman shari'ar tiyo PD / Girman tashar tashar kwamfutar hannu | 570mm*360*240mm/395*295*105mm |
Nuna nauyin ƙarshen kwamfutar hannu | 0.85kg |
Gabaɗaya girman akwatin | 570mm*360*240mm |
Yanayin aiki | |
Yanayin aiki | -20 ℃ ~ 50 ℃ |
Yanayin yanayi | 0 ~ 90% RH |
IP matakin | 54 |
GDPD-414H Mai Gano Sashe na Fitar da Hannu