Kayan Aikin Gwajin Babban Wuta

  • Partial Discharge Test System GIT series

    Tsarin Gwajin Fitar Sashe na GIT

    GIT jerin ana amfani da ko'ina don babban ƙarfin lantarki, babban ƙarfin kayan aikin wutar lantarki na GIS wanda aka keɓe tare da gwajin ƙarfin lantarki, gwajin fitarwa na juzu'i da gwajin daidaito na GIS, wanda ya dace da tashar GIS, masana'antar kayan wutar lantarki ta GIS, masana'anta nau'in kwandon lantarki.

     

     

     

     

     

  • Partial Discharge Test System GDYT series

    Tsarin Gwajin Fitar Sashe na GDYT

    An yi amfani da shi sosai a masana'antar lantarki, sassan sarrafa wutar lantarki, cibiyoyin bincike da jami'o'i.

     

     

  • PD free Variable Frequency Test System

    PD Kyautar Tsarin Gwajin Mita Mai Sauyawa

    GDYT-350kVA/70kV PD free Resonant Test System ya ƙunshi PD free m mitar samar da wutar lantarki, HV aunawa akwatin, excitation transformer, kadaici gidan wuta, Resonant reactor, da capacitive ƙarfin lantarki rarraba.

     

     

     

     

     

  • AC Dielectric Test Equipment with manual control unit GDYD-D

    Kayan Gwajin AC Dielectric tare da naúrar sarrafa hannu GDYD-D

    Gwajin AC Hipot hanya ce mai inganci kuma kai tsaye don gwada ƙarfin rufi don kayan lantarki, na'urori, ko injuna.Yana bincika lahani masu haɗari waɗanda ke tabbatar da ci gaba da aiki na kayan lantarki.

  • VLF AC Hipot Test Set

    Saitin Gwajin VLF AC Hipot

    Juriya gwajin ƙarfin lantarki shine muhimmin gwajin rigakafi don kayan lantarki.An kasu kashi biyu: AC da DC jure irin ƙarfin lantarki gwajin.

  • AC Dielectric Test Equipment with manual control unit GDYD-M

    Kayan Gwajin AC Dielectric tare da naúrar sarrafa hannu GDYD-M

    Aikace-aikace na yau da kullun sun haɗa da gwajin na'urorin wuta, masu sauyawa, igiyoyi, capacitors, dandamali na injin injin, bulogin sanduna masu zafi, kwalabe masu ban sha'awa da sauran kayan aikin da ke da alaƙa kamar injin katsewa, barguna, igiyoyi, safar hannu, tiyo na'ura mai ƙarfi, janareta na kayan wuta.

  • VLF AC Hipot Test Set 80kV

    VLF AC Hipot Test Saitin 80kV

    Juriya gwajin ƙarfin lantarki shine muhimmin gwajin rigakafi don kayan lantarki.An kasu kashi biyu: AC da DC jure irin ƙarfin lantarki gwajin.

  • Insulation Materials Hipot Test Set GDJS-65

    Saitin Gwajin Hipot Makarantun Jiki GDJS-65

    Ana amfani da shi don gwada aikin insulation don safofin hannu, takalma, mats, huluna, sanda, Electroscope da dai sauransu. Yana iya gwada safofin hannu / takalma na 6pcs a lokaci guda, kuma 5pcs insulation sanduna.

  • DC High Voltage Generator GDZG-300

    DC High Voltage Generator GDZG-300

    GDZG-300 jerin DC high irin ƙarfin lantarki ma'aikaci ne gwada DC high irin ƙarfin lantarki ga tutiya oxide lighting arrester, Magnetic hura arrester, ikon igiyoyi, janareta, gidajen wuta, sauya, da sauran kayan aiki, wanda ya dace da wutar lantarki reshe, ikon sashen na masana'antu, sassan binciken kimiyya, layin dogo, masana'antar sinadarai, masana'antar wutar lantarki.

  • DC Hipot Test Set GDZG-S

    Saitin Gwajin Hipot na DC GDZG-S

    GDZG-S jerin kayan aiki ne na gwajin wutar lantarki na DC da kuma zubar da ruwa na yanzu na janareta mai sanyaya ruwa a cikin yanayin ruwa ta hanyar, wanda gaba daya shawo kan matsalolin dogon busa ruwa, ruwa mai wuya ya bushe, mai sauƙin haifar da arcing a cikin nada. .Na'urar tana da haske, mai sauƙin wayoyi, kuma mai sauƙin karantawa.Wutar lantarki ramuwa yana fitowa kai tsaye ta shari'ar.

  • 50kV AC DC Dielectric Test Equipment GDYD-53D

    50kV AC DC Dielectric Gwajin Kayan aikin GDYD-53D

    Gwajin AC hi-pot hanya ce mai inganci kuma kai tsaye don gwada ƙarfin rufewa don kayan lantarki, na'urori, ko injuna.Yana bincika lahani masu haɗari waɗanda ke tabbatar da ci gaba da aiki na kayan lantarki.

  • AC DC High Voltage Divider

    AC DC High Voltage Divier

    GDFR-C1 jerin AC / DC dijital mita ne a kan-site kayan aiki, wanda gwada duka AC da DC ƙarfin lantarki.Ya ƙunshi mai rarraba wutar lantarki da kayan aunawa.

     

12Na gaba >>> Shafi na 1/2