GD6100C Transformer Insulation Oil Tan Delta Tester/Mai Gwajin Dielectric Mai
GD6100C Atomatik Daidaitaccen Mai Dielectric Loss Tester, ana amfani dashi don auna ma'aunin dielectric dissipation factor da DC resistivity na insulating mai da sauran insulating taya.The kayan aiki intergrates tare da gwajin mai cell, zazzabi mai kula, zafin jiki firikwensin, dielectric asarar gwajin gada, AC gwajin ikon, misali capacitor, high juriya mita, DC high ƙarfin lantarki tushen da sauran manyan aka gyara.
●Tantanin gwajin ya ɗauki tsarin tsarin lantarki guda uku bisa ga daidaitattun GB/T5654-2007 na ƙasa, tare da tazarar lantarki 2mm, wanda zai iya kawar da tasirin ƙarfin ƙarfin da yabo akan sakamakon gwajin asarar dielectric.Na'urar tana dauke da na'urar solenoid mai magudanar ruwa, kuma za mu iya zubar da kwayar gwajin ba tare da cire ta ba kuma mu kurkura da samfurin gwajin.
●Kayan aikin yana ɗaukar dumama shigar da mitar mitar, PID algorithm sarrafa zafin jiki.Wannan hanyar dumama tana da fa'idodin rashin tuntuɓar tantanin halitta da na'urar dumama, dumama iri ɗaya, saurin sauri, sarrafawa mai dacewa, da tsananin sarrafa zafin jiki a cikin kewayon kuskuren zafin da aka saita.
●Matsakaicin ma'auni na ciki shine SF6 mai cike da iskar gas mai ƙarfi uku-electrode, kuma asarar wutar lantarki da ƙarfin wutar lantarki ba ya shafar yanayin yanayi, zafi da sauransu, ta yadda za'a iya tabbatar da daidaiton kayan aikin koda bayan dogon amfani.
●Samar da wutar lantarki ta AC tana amfani da jujjuyawar AC-DC-AC, wanda yadda ya kamata ya hana jujjuyawar wutar lantarki da mitoci daga shafar daidaiton auna dielectric.Ko da janareta, kayan aikin na iya aiki yadda ya kamata.
●Cikakkun aikin kariya.Lokacin da akwai sama da ƙarfin lantarki, sama da gajeriyar kewayawa na yanzu ko babban ƙarfin lantarki, kayan aiki na iya yanke matsa lamba da sauri, kuma suna ba da saƙon faɗakarwa.Lokacin da zazzabi na firikwensin gazawar ko ba a haɗa shi ba, kayan aikin kuma zai ba da saƙon faɗakarwa.
●Akwai ƙayyadaddun yanayin zafi a cikin matsakaicin mitar shigar da wutar lantarki.Lokacin da zafin jiki sama da digiri 120, kayan aikin yana 'yantar da relay kuma yana dakatar da dumama.
●Saitin ma'aunin gwaji mai dacewa.Zazzabi saitin kewayon 0 ~ 125 digiri, kewayon saitin wutar lantarki na AC 500 ~ 2200V, kewayon saitin wutar lantarki na DC 0 ~ 500V.
●Amfani da babban allo LCD nuni, tare da hasken baya da bayyanannen nuni.Ƙaƙwalwar abokantaka, kawai bi saurin menu na Sinanci, shigar da umarni, ana iya gwada kayan aikin ta atomatik.Kuma adana da buga sakamakon gwaji ta atomatik.
●Ginin agogon ainihin lokacin, ranar gwajin da lokacin za'a iya ajiyewa, nunawa da buga tare da sakamakon gwajin.
●Ayyukan daidaitawa na busassun tantanin halitta mai tsabta.Auna ƙarfin busassun tantanin halitta da hasara na dielectric zai iya ƙayyade yanayin tsaftacewa da haɗuwa.Ana adana bayanan daidaitawa ta atomatik don haka ya sauƙaƙe lissafin izinin dangi da tsayayyar DC.
| Samar da wutar lantarki | AC 220V± 10% |
| Mitar wutar lantarki | 50Hz/60Hz ± 1% |
| Ma'auni kewayon | Yawan aiki: 5pF ~ 200pF |
| Auna daidaito | Ƙarfin ƙarfi: ± (1% na karatun +0.5pF) |
| Ƙaddamarwa | Yawan aiki: 0.01pF |
| Ma'aunin zafin jiki da aka auna | 0 ~ 125 digiri |
| Kuskuren auna zafin jiki | ± 0.5 digiri |
| AC Test Voltage (RMS) | 500 ~ 2200V Ci gaba da daidaitawa, mitar 50Hz |
| Gwajin Voltage DC | 0 ~ 500V Ci gaba da daidaitawa |
| Amfanin wutar lantarki | 100W |
| Yanayin yanayi | 0 ~ 40 digiri |
| Dangantakar zafi(RH) | <75% |
| Girma | 500×360×420 |
| Jimlar nauyi | 22kg |