GDJF-2008 Mai Nazari na Sashe na Fuska
GDJF-2008 Mai Gano Ciki Mai Sauƙi yana auna juzu'i na fitarwa don samfuran kamar su masu canza wuta, inductor juna, masu sauya HV, masu kama zinc monoxide da igiyoyin wuta.Hakanan yana iya yin gwaje-gwajen nau'in da sa ido kan aikin rufewa.
Wannan nau'in yana da fa'idodi na babban hankali, fa'ida mai ƙarfi, sanye take da kyau don gano ɓarna naúrar shigar da ƙarin bambance-bambancen maɗaurin mitar (9 a duka).Bayan saitin da ya dace, ana iya karanta adadin kuzarin fitarwa kai tsaye.Ana nuna mita masu nuni da dijital lokaci guda.
Ana amfani da wannan na'urar ganowa sosai a tashoshin wutar lantarki, masana'anta, da cibiyoyi.
●Yanayin yanayi: 0-40℃±2℃.
●Dangi zafi: ≤80%
●Wutar lantarki: 220V± 10%, 50HZ.
●Babu tashin hankali da girgizar injina.
●Ya kamata a sanya na'urar a cikin yanayi ba tare da ƙura da lalata ba, samun iska mai kyau.Kada a tsoma baki da karfi da lantarki.
●Abubuwan buƙatun ƙasa: juriya na ƙasa | 1Ω.
●Za a gwada kewayon ƙarfin ƙarfin 6PF-250μF.
●Gwajin gwaji (wanda aka nuna a Table.1).
| Naúrar shigarwaA'a. | Tuning capacitance | Naúrar | Hankali (pC)(Unsimmetrical circuit) |
| 1 | 6-25-100 | pF | 0.02 |
| 2 | 25-100-400 | pF | 0.04 |
| 3 | 100-400-1500 | pF | 0.06 |
| 4 | 400-1500-6000 | pF | 0.1 |
| 5 | 1500-6000-25000 | pF | 0.2 |
| 6 | 0.006-0.025-0.1 | mF | 0.3 |
| 7 | 0.025-0.1-0.4 | mF | 0.5 |
| 8 | 0.1-0.4-1.5 | mF | 1 |
| 9 | 0.4-1.5-6.0 | mF | 1.5 |
| 10 | 1.5-6.0-25 | mF | 2.5 |
| 11 | 6.0-25-60 | mF | 5 |
| 12 | 25-60-250 | mF | 10 |
| 7R | Juriya |
| 0.5 |
●Ƙungiyar Amplifier
Ƙarƙashin ƙasa: 10KHZ, 20KHZ, 40KHZ (na zaɓi)
Babban tasha: 80KHZ, 200KHZ, 300KHZ (na zaɓi)
● Amplifier samun daidaitawa
Ikon sarrafawa - akwai gears 6 don daidaitawa mara kyau, ribar kowane kayan aiki shine 20 ± 1db
Kyakkyawan iko ≥ 20 db
● Lokacin windows
Nisa na taga, daidaitacce 15o-150o
Matsayin taga, daidaitacce 0o-170o
Ana iya buɗe tagogi biyu a lokaci ɗaya ko dabam.
● Mitar fitarwa
Nunin dijital
PD nuni: LED 3½ lambobi
0-100.0 iyaka na kuskure <± 3% (cikakken sikelin)
● Ellipse lokaci tushe
Mitar: 50Hz da mitar sabani
Launin nunin Elliptic rawaya ne
Juyawa Elliptic: kowane kayan aiki shine 30 °, ana iya yin jujjuya 180 °.
Nuni: ellipse - madaidaiciyar layi
Babban mitar lokaci tushe elliptical shigar da wutar lantarki kasa da 220 V, ikon ci <1 VA
● Kulle waveform
Makulle da ake buƙatar sigar motsi na kowane lokaci don sauƙaƙe dubawa da bincike
● Gwajin Mitar Wuta
Rage: 100KV (Za'a iya fadada shi)
Nuni 31/2 dijital ƙarfin lantarki
Daidaito: mafi kyau fiye da ± 2% (cikakken sikelin)
● Ciki, wajen aikin alamar sifili
●Girma: 450×450×190 mm
●Nauyi: kusan 16kg