Ana iya amfani da GDJW-40B don gwada ƙarfin wutar lantarki na cajin da aka dakatar da insulator ko ganowar dakin gwaje-gwaje na insulator da aka dakatar, da kuma ba da damar gano matsalar ɓoyayyun na'urar yadda ya kamata, haɓaka amincin aiki na tsarin grid ɗin wutar lantarki, da haɓaka ingantaccen aiki. ingancin aiki na ma'aikatan layin da ke gudanar da gwajin rayuwa.Wannan samfurin yana ɗaukar watsawa mara igiyar waya, tazarar sadarwa tsakanin mai ganowa da tashoshi na hannu zai iya zuwa sama da mita 100, Sanya tsarin aunawa da aminci da aminci, mai sauri da daidaito.Bugu da ƙari, kayan aikin yana da ƙaƙƙarfan aikin hana tsangwama, cikakken cika daidaitattun buƙatun (EMC), daidaitawa da yanayin kutsawar filin lantarki iri-iri.
●Wutar lantarki mai aiki: 35-1000KV, matakan ƙarfin lantarki daban-daban suna aiki.
●Ƙimar aunawa ƙarfin lantarki: 0-40kV (ana iya daidaita ƙarfin lantarki na musamman).
●Kuskuren aunawa: ≤± 1%.
●Yawan samfur: sau 10/S.
●Saitunan lokacin kwanan wata: daidaita kwanan wata da lokaci, don sauƙaƙe masu amfani don lilo, duba bayanan tarihi.
●Saitunan lokacin haske na baya: mai haske mai dorewa, kashewa akai-akai, ana iya saita mintuna 0-999.
●Saitunan kashe wutar lantarki ta atomatik: ba za a iya saita mintuna 0-999 ba.
●Nisan watsawa na tashar hannu da mai ganowa shine ≤100m.
●Ƙirar nau'i-nau'i da yawa, aiki mai ƙarfi, mafi aminci da dacewa.
●Ƙirar haɗin gwiwa ta duniya, tana ba da damar daidaita yanayin aunawa cikin sassauƙa bisa ga matsayin dakatarwar igiyar insulator.
●Mai kariya sau biyu, ƙarfin hana tsangwama mai ƙarfi, cikakken cika ka'idodin EMC.
●Keɓancewar injin-na'ura, mai sauƙin aiki.
| Kewayon auna wutar lantarki | 0-40kV (na musamman ƙarfin lantarki za a iya musamman) |
| Kuskuren aunawa | ± 1% |
| Ƙaddamarwa | 0.01kV |
| Yawan samfur | 10sau/S |
| Aiki na yanzu | ≤120mA(Tashar ta hannun hannu),≤40mA(Mai ganowa) |
| Tushen wutan lantarki | 2*1.5VAA busasshen baturi (Tasha mai riƙe da hannu) 2*1.5VAAA bushe baturi (Mai ganowa) |
| Lokacin aiki mai dorewa | ≥12h |
| Nisa watsawa | ≥100m (isasshen wutar lantarki) |
| Nunawa | Nunin LCD, ana iya nunawa a fili a ƙarƙashin hasken rana. |
| Yanayin aiki | -35 ℃ ---+60 ℃ |
| Yanayin ajiya | -40℃---+65℃ |
| Dangi zafi | ≤90)RH Marasa narke |
| A'a. | Tsarin asali | Naúrar | Qty | Magana |
| 1 | Tashar ta hannun hannu | saita | 1 | |
| 2 | Dedicated ganowa | yanki | 1 | |
| 3 | A,B Mai ganowa | tushen | 2 | |
| 4 | AA Dry baturi (1.5V) | sashe | 2 | |
| 7 | AAA Dry baturi (1.5V) | sashe | 2 | |
| 8 | Shigo da akwati mai ɗaukuwa | yanki | 1 | |
| 9 | 220kV Insulation sanda | tushen | 1 | ≤220kV dace da4sassa4M sandar rufi,≥330kV daidaita da6 sassan6M sandar rufi |
| 10 | Littafin aiki | kwafi | 1 | |
| 11 | Rahoton gwaji | kwafi | 1 | |
| 12 | Katin garanti | kwafi | 1 | |
| 13 | Jerin kaya | kwafi | 1 |