GDOT-80C Insulation Breakdown Tester 80kV
Akwai adadi mai yawa na kayan lantarki a cikin tsarin wutar lantarki, tsarin layin dogo da manyan ma'adanai da masana'antu na petrochemical, rufin su na ciki galibi rufi ne mai cike da mai.Ƙarfin dielectric na insulating mai gwaji ne na yau da kullun na wajibi.Don saduwa da bukatun kasuwa, kamfaninmu ya haɓaka da kuma samar da jerin ƙarfin gwajin ƙarfin dielectric mai dielectric bisa ga ma'aunin IEC156" Insulating mai-ƙayyade ƙarfin dielectric" da ƙimar masana'antar ƙasa DL-474 · 4-92DL/T596 -1996"Lambar gwajin rigakafi don kayan aikin wutar lantarki".
Wannan kayan aikin yana ɗaukar microcomputer mai guntu guda ɗaya a matsayin jigon, yana gane duk aikin sarrafa kansa na gwajin, yana da ma'aunin ma'auni mai girma, yana inganta ingantaccen aiki sosai, kuma yana rage ƙarfin aiki na ma'aikata sosai.A lokaci guda, kayan aiki yana da ƙananan bayyanar kuma ya dace don ɗauka.
●Yana ɗaukar microprocessor don kammala ayyukan haɓakawa ta atomatik, riƙewa, motsawa, a tsaye, ƙididdigewa, bugu, da sauransu, kuma yana iya yin zagayawa mai jure gwajin ƙarfin lantarki a cikin kewayon 0-80 kV.
●An kafa kofin mai na kayan aikin ta hanyar jefa gilashin musamman na lokaci ɗaya, wanda ke hana tsangwama kamar zubar mai.
●Ƙirar samfurin babban gefe na kayan aikin yana ba da damar ƙimar gwaji don shigar da mai sauya A / D kai tsaye, guje wa kurakurai da aka haifar a cikin da'irar analog, da kuma sanya sakamakon auna daidai.
●Matsayin aiwatar da gwajin kayan aiki sun haɗa da matakan masana'antu, ƙa'idodin ƙasa da ƙa'idodin ƙasashen waje, kuma aikin yana da sauƙi kuma mai dacewa.
●Tare da wuce gona da iri, na yau da kullun, iyaka da sauran kariya don tabbatar da amincin masu aiki.Kuma yana da ƙarfin hana tsangwama mai ƙarfi da ingantaccen ƙarfin lantarki.
●Wutar lantarki mai fitarwa: 0-80kV
●Adadin karkatar da wutar lantarki: <1%
●Yawan aiki: 1.5kVA
●Kofin mai: 240ml
●Daidaiton aunawa: ± 3%
●Ƙarfafa ƙarfin lantarkiƙimar: 2kV/s, 3kV/s na zaɓi, kuskure: 0.2kV/s
●Shigar da wutar lantarki: AC220V± 20%, 50Hz±5Hz
●Ƙarfin wutar lantarki: <200W
●Yanayin aiki: 0-40 ℃
●Humidity: <85% RH
●Girma: 430*350*370mm
| GDOT-80C kayan aiki | guda 1 |
| Kofin mai (250ml) | guda 1 |
| Igiyar wutar lantarki | guda 1 |
| Kebul na ƙasa | guda 1 |
| Kayan fuse | 2 guda |
| Kwaya mai motsawa | 2 guda |
| Standard 2.5mm | guda 1 |
| Tweezer | guda 1 |
| Buga takarda | 1 nadi |
| Jagorar mai amfani | 1 kwafi |
| Rahoton gwajin masana'anta | 1 kwafi |

Sauran lantarki na zaɓi ne