GDP-8000CM SF6 Mai Gwajin Raɓar Gas (Tsarin Madubin Chilled)
GDP-8000CM Maɗaukakin Chilled Mirror SF6 Gas Dew Point Tester an tsara shi musamman don gano ƙarancin iskar gas na SF6 da aka yi amfani da shi a duk yankin zafin jiki na masana'antar wutar lantarki, wanda ya dogara da sanyin Stryn da ƙa'idar auna madubi mai sanyi.
Ba wai kawai ya warware matsalar cewa Peltier's refrigeration manufa madubi surface raɓa ma'auni ba za a iya amfani da a cikin high zafin jiki filin, amma kuma warware matsalar da cewa gwajin data na resistive da capacitive danshi mita ba zai iya zama barga, da gwajin gudun ne. a hankali, kuma bayanan auna ba daidai ba ne.Ana iya gano abun ciki na danshi na gas na SF6 a zazzabi na ƙasa da 60ºC a cikin mahalli tare da daidaiton raɓa ± 0.2ºC.
Wannan samfurin yana da saurin gwaji na sauri, ingantaccen aiki da ingantaccen maimaitawa.Ya dace da gano micro danshi na SF6 sabon gas, iskar gas mai sabuntawa, gas mai gudana da iskar gas a cikin masana'antar wutar lantarki.
●Kula da danshi na kayan lantarki na gas na SF6 don wutar lantarki.
●Gwajin ingancin Gas Silinda SF6
●High tsarki gas masana'antu
●Masana'antar Semiconductor bushewar iskar gas
●Bincike da amfani da ci gaba
●Kulawar ɗaki/bushewar gida
●Metal zafi magani wurin da dakin gwaje-gwaje masana'antu zafi gane zafi, kamar iska, CO2, N2, H2, O2, SF6, He, Ar da sauran inert gas.
●Mafi kyau fiye da ± 2℃ daidaito aunawa.
●Dukkanin ƙirar kayan aikin polymer, yana tabbatar da cewa babu wani abin rataye bangon ruwa kuma yana ba da garantin saurin gwajin.
●Ana amfani da bawul ɗin bawul ɗin da ba shi da mai don tabbatar da daidaiton ƙimar da aka auna.
●Algorithms na software na ci gaba suna haɓaka daidaiton gwajin na'urori masu auna firikwensin.
●Haɗin tsarin daidaitawar chassis, masu amfani za su iya haɗa kayan aiki da kayan haɗi masu alaƙa cikin sauƙi.Ana ɗaukar fakitin gabaɗaya, wanda ke sa mai amfani ya sami kwanciyar hankali.
●Fara gwaji, babu buƙatar preheat kumaoscillate.
●Canjin yanayin zafi da gyaran bayanan matsa lamba.
●Fasahar kwamfuta mai ban mamaki.
●Babban ƙarfin baturin lithium mai ƙarfi, gane AC da wadatar wutar lantarki dual DC.Ba a buƙatar ƙarfin AC na kan-site.Batirin Lithium yana ci gaba da aiki sama da awanni 8 ba tare da buƙatar wutar lantarki ta waje ba.
●Anti-electromagnetic tsangwama ƙirar kewaye don tabbatar da amincin samfur.
●Yana iya faɗaɗa sadarwar USB, sadarwar serial, tsarin sadarwar mara waya, da kuma gane ayyukan sadarwa da bugu na babbar kwamfuta.
●Ƙwaƙwalwar ƙima mai girma, wanda zai iya gane saiti 1000 na ayyukan ajiyar bayanai.
●Ana iya amfani da aikin gyaran hanyar iskar gas don tsarkake bututun gwajin kafin aikin gwajin filin, wanda ya rage lokacin gwajin.(na zaɓi)
●Kayan aikin yana da aikin dawo da iskar gas don dawo da iskar ma'aunin sulfur hexafluoride.
●Bayanan gwajin sun tsaya tsayin daka kuma suna iya samar da madaidaitan ma'aunin raɓa biyu da ƙimar raɓa da aka canza a 20 ℃.
●Mafi kyawun wurin gwajin gwaji yana nuna cewa mai amfani zai iya daidaita kwararar iskar gas cikin hankali da sauri.Rage lokacin gwaji.
●An ƙera mashigar iska tare da ƙaramin haɗin haɗin kai, kuma hanyar iskar da za a gwada ba za ta zube ba lokacin da aka katse hanyar iska.
| Hanyar aunawa | Hanyar madubi mai sanyi |
| Kewayon aunawa | maki raɓa -110 ℃ - - + 20 ℃ (goyan bayan ppm) |
| Daidaito | ± 2 ℃ (lokacin da zafin raɓa yana ƙasa da 0 ℃, firikwensin firikwensin shine wurin sanyi) |
| Lokacin amsawa | 63% [90%] +20→-20℃ Td 5s[45s] -20→-60℃ Td 10s[240s] |
| Ƙaddamarwa | 0.01 ℃ |
| Maimaituwa | ± 2 ℃ |
| Naúrar nuni | ℃, ppm, ℃P20 (ƙimar da aka canza a 20 ℃) |
| Gudun iskar gas | 400-600ml/min |
| Nuni mai gudana | 0-1000ml dijital kwararameter |
| Misalin matsa lamba gas | ≤1MPa |
| Tushen wutan lantarki | 220VAC ± 10%, 50Hz, AC / DC amfani, over-charge kariya, ci gaba da aiki ba kasa da 8hours. |
| Yi amfani da zafin yanayi | -20--+60 ℃ |
| Yanayin yanayi | 90% RH |
| Tasirin ƙimar ƙimar | Babu tasiri na matsa lamba da kwarara |
| Girma | 395*295*155mm |
| Nauyi | kusan 2kg |

便携式冷镜法SF6气体露点仪.jpg)
便携式冷镜法SF6气体露点仪-1.jpg)





