GDWS-311RC SF6 Gas Dew Point Gwajin
GDWS-311RC shine ingantaccen kayan aiki don gwada raɓa na iskar SF6.Babban bangaren shine na'urori masu auna firikwensin DRYCAP wanda kamfanin Finland Vaisala ya samar.Tare da ƙwararrun kwakwalwan kwamfuta na kayan aiki da ingantattun algorithms na software na STMicroelectronics, mun samar da sabon ƙarni na kayan gwajin danshin gas.
●Kula da danshi na kayan lantarki na gas na SF6 don wutar lantarki
●Gwajin ingancin Gas Silinda SF6
●High tsarki gas masana'antu
●Masana'antar Semiconductor bushewar iskar gas
●Bincike da amfani da ci gaba
●Kulawar ɗaki/bushewar gida
●Metal zafi magani wurin da dakin gwaje-gwaje masana'antu zafi gane zafi, kamar iska, CO2, N2, H2, O2, SF6, He, Ar da sauran inert gas.
●Mafi kyau fiye da ± 2℃ daidaito aunawa.
●Duk hanyar gas ɗin ƙirar kayan aikin polymer ne, yana tabbatar da cewa babu wani abin rataye bangon ruwa kuma yana ba da garantin saurin gwajin.
●Ana amfani da bawul ɗin bawul ɗin da ba shi da mai don tabbatar da daidaiton ƙimar da aka auna.
●Algorithms na software na ci gaba suna haɓaka daidaiton gwajin na'urori masu auna firikwensin.
●Haɗin tsarin daidaitawar chassis, masu amfani za su iya haɗa kayan aiki da kayan haɗi masu alaƙa cikin sauƙi.Ana ɗaukar fakitin gabaɗaya, wanda ke sa mai amfani ya sami kwanciyar hankali.
●Fara gwaji, babu buƙatar preheat da oscillate.
●Canjin yanayin zafi da gyaran bayanan matsa lamba.
●Fasahar kwamfuta mai ban mamaki.
●Babban ƙarfin baturin lithium mai ƙarfi, gane AC da wadatar wutar lantarki dual DC.Ba a buƙatar ƙarfin AC na kan-site.Batirin Lithium yana ci gaba da aiki sama da awanni 8 ba tare da buƙatar wutar lantarki ta waje ba.
●Anti-electromagnetic tsangwama ƙirar kewaye don tabbatar da amincin samfur.
●Aikin sake yin amfani da iskar gas, yanayin yanayi.
●Bayanan gwajin sun tsaya tsayin daka kuma suna iya samar da madaidaitan ma'aunin raɓa biyu da ƙimar raɓa da aka canza a 20 ℃.
●Mafi kyawun wurin gwajin gwaji yana nuna cewa mai amfani zai iya daidaita kwararar iskar gas cikin hankali da sauri.Rage lokacin gwaji.
●An ƙera mashigar iska tare da ƙaramin haɗin haɗin kai, kuma hanyar iskar da za a gwada ba za ta zube ba lokacin da aka katse hanyar iska.
●Hanyar aunawa: Ƙa'idar ma'aunin juriya da ƙarfi
●Ma'auni: ma'aunin raɓa -80 ℃ - + 20 ℃ (goyan bayan ppm)
●Daidaito: ± 2 ℃
(lokacin da zafin raɓa ya kasa 0 ℃, firikwensin firikwensin shine wurin sanyi)
●Lokacin amsawa: 63% [90%]
+20→-20℃ Td 5s[45s]
-20→-60℃ Td 10s[240s]
●Tsayi: 0.01 ℃
●Maimaituwar iyawa: ± 0.5℃
●Naúrar nuni: ℃, ppm, ℃P20 (ƙimar da aka canza a 20 ℃)
●Gudun iskar gas: 400-600ml/min
●Nuni mai gudana: 0-1000mL Mitar kwararar dijital
●Misalin matsin lamba: ≤1MPa
●Ƙarfin wutar lantarki: 220VAC ± 10%, 50Hz, AC / DC amfani, ci gaba da aiki ba kasa da 8 hours ba.
●Yi amfani da yanayin zafi: -20--+60 ℃
●Yanayin muhalli: 90% RH
●Tasirin ƙimar ƙimar: Babu tasiri na matsa lamba da kwarara
●Girma: 395*295*155mm
●Nauyi: kusan 2kg
| Babban naúrar | guda 1 |
| Adafta | 1 saita |
| Teflon bututu (gami da kwarara daidaita bawul da sauri haši) | 1 saita |
| Bututun wutsiya | 1 saita |
| Kayan kayan gyara | 1 saita |
| Caja | guda 1 |
| Mai amfani's Guide | 1 kwafi |
| Rahoton Gwaji | 1 kwafi |