GDUP-3000 Tsabtace Sine Wave AC Samar da Wuta
GDUP-3000 shine madaidaicin šaukuwa šaukuwa tsantsa igiyar igiyar ruwa akan wurin gwajin wutar lantarki na AC.Har ila yau, an san shi da tashar wutar lantarki ta AC da DC, wutar lantarki ta gaggawa ta AC da DC, wutar lantarki ta gwaji, wutar lantarki ta wayar hannu.Yana da amintaccen baturin lithium-ion mai ƙarfi da ingantaccen fasahar jujjuyawar SPWM, tare da nauyi mai sauƙi, ƙaramin girman, tsawon rai da babban ƙarfi.
An yi amfani da shi sosai a cikin kayan aiki na waje kamar kayan aikin wutan lantarki gyaran gaggawa, gwajin filin wutar lantarki, ofishin wayar hannu, ceton likita, ceton gaggawa na wuta, kare muhalli, tallafin sadarwa na gaggawa, da kuma ajiyar wutar lantarki.Hakanan yana ba da amintaccen tushen wutar lantarki don kayan aiki a cikin dakin gwaje-gwaje ko a fagen.
1. 220V/50Hz tsantsa sine kalaman AC fitarwa
2. Iya siffanta 110V, 60Hz fitarwa (fitarwa zuwa Japan da Tarayyar Turai)
3. 12V / 10A DC fitarwa, 5V / 2A-USB dual tashar fitarwa;
4. 24V / 20A DC fitarwa;
5. Hasken gaggawa na LED;
6. Nuni mai hankali, nunin ƙarfin dijital na baturi, ƙarfin shigarwa da fitarwa da sauran lokacin aiki;
7. Caja mota, cajin rana (na zaɓi)
●Batir lithium polymer mai ƙarfi da aka gina a ciki, babban ƙarfin aiki, caji mai aminci da caji, babu ƙonewa, babu fashewa.
●Fiye da 1000 caji da zagayowar fitarwa.
●Yi aiki da kyau a cikin -20 ℃ ~ +50 ℃.
●Babban aiki, babu gurɓatawa, abokantaka na muhalli.
●Karamin fitar da kai: a dakin da zafin jiki na wata daya, fitar da kai kasa da 5%.
●Tare da fitarwa na DC 5, 12, 24V, fitarwa AC 110V/220V.
●Yana da aikin fitarwa na cascading, wanda zai iya gane sauyawa ta atomatik tsakanin manyan hanyoyin samar da wutar lantarki, da kuma tsawaita lokacin samar da wutar lantarki ta hanyar cascading matakai da yawa.
●Babban girman allo LCD, ƙarfin nuni mai ɗaukar ido, halin yanzu da sauran sigogi.
●AC tsantsar fitarwar sine mai ƙarfi tare da ƙarfin nauyi mai ƙarfi.
●Yana da ayyuka na kariya ta atomatik kamar cajin da ya wuce kima, fiye da fitarwa, nauyi mai yawa, zafi mai zafi da gajeriyar kewayawa.
●Karami, mai sauƙi da ƙarfi: baturin ƙarfinsa ɗaya shine 50% ƙasa da nauyin acid gubar.Ƙarƙashin ƙarfin ɗaukar nauyi iri ɗaya, sararin bene kusan kashi 30% na baturin gubar-acid.
●Sanya jakar baya ta musamman, mai sauƙin ɗauka.
●Adadin riƙe ƙarfin baturi da aka adana na watanni 12 shine ≥80.
●Matsayin kariya na baturi: IP56.
| Samfura | GDP-3000 |
| Ikon fitarwa mai ci gaba | 3000W |
| Ƙarfin ƙarfi | 6000W |
| Fitar wutar lantarki | AC tsantsar sine wave 220V/50Hz ko AC 110V/60Hz DC 12V10A 5V2A 24V20A 51.8V50A 5V2A |
| Samfurin baturi | 18650-22P14S (3.7V 2600mAh) |
| Iyawa | 51.8V 57.2AH |
| Rayuwar sabis | 70% @ 1000 sake zagayowar |
| Lokacin caji | 5 ~ 6 hours (caja na ciki 58.8V 10A) |
| Kariya | Ƙarfin wutar lantarki, yawan zafin jiki, nauyi mai yawa, gajeren kewayawa AC, dawo da atomatik |
| Yanayin aiki | -20 ℃ ~ 60 ℃ |
| Hanyar sanyaya | Fan tilasta sanyaya |
| Girman | L515.5*W434.5*H270 (mm) |
| Kayan harsashi | Anti-shock ABS |
| Nauyi | 33kg |
| No | Gwaji abu | Yanayin gwaji | Duba abu |
|
1 | Gwajin tsayi | 1. Matsi ≤11.6Kpa, T = 20 ± 5 ℃ 2. Babu kunshin, babu wutar lantarki | 1. Bayyanar 2. Ayyukan samar da wutar lantarki |
|
2 | Gwajin zafin jiki | Zazzabi tsakanin 40 ± 2 ℃ da 75 ± 2 ℃ Ana maimaita gwajin har sau 10 Kunna don minti 30. | 1. Bayyanar 2. Ayyukan samar da wutar lantarki |
|
3 | Gwajin girgiza | Girman: 1.52mm Kewayon mitar dubawa: 5 ~ 10Hz, saurin dubawa: kusan 10m2/ S3, Kewayon mitar dubawa: 0 ~ 200Hz, saurin dubawa: kusan 3m2/ S3, Kewayon mitar dubawa: 200 ~ 500Hz, saurin dubawa: kusan 1m2/S3, Kowane gwajin jijjiga yana ɗaukar mintuna 20.Jijjiga yana faruwa daga dukkan bangarorin X, Y da Z axis.Siffar ta kasance cikakke, samfurin zai iya wuce duk gwajin aiki, kuma rubutu akan lakabin a bayyane yake, da umarnin aiki.Samfurin ba shi da rawar jiki kuma babu hayaniya;An ɗaure dunƙule ba tare da zamewa ba. | 1. Bayyanar 2. Ayyukan samar da wutar lantarki |