Gwajin yabo na DC ta amfani da aDC babban ƙarfin lantarki janaretashine don yin nazari gabaɗaya ingancin rufin samfurin da aka gwada ta hanyar girman ɗigowar halin yanzu, canjin ɗigogi yayin ci gaba da haɓakawa, da kwanciyar hankali na ɗigogi na yanzu lokacin da ƙarfin gwajin ya kai ƙimar ƙima..Gwajin jurewar wutar lantarki na DC shine yin hukunci akan ko kayan da aka haɗa sun cancanta ko a'a ƙarƙashin ƙayyadadden lokaci da ƙayyadaddun ƙarfin lantarki, kuma kayan insulating ba a karye ba kuma ko akwai walƙiya.
HV Hipot GDZG-300 Series DC High Voltage Generator
DC high irin ƙarfin lantarki janaretaana amfani da su sosai a sassan gwajin wutar lantarki.Gudanar da gwaje-gwajen babban ƙarfin wutar lantarki na DC akan kayan lantarki masu ƙarfin lantarki kamar masu kama zinc oxide, igiyoyin wuta, masu canza wuta, da janareta.Yana da kayan aiki mai mahimmanci don sana'ar gwajin ƙarfin lantarki.Koyaya, wasu dalilai zasu shafi daidaiton ƙimar gwajin.Akwai abubuwa da yawa waɗanda ke shafar sakamakon ma'aunin janareta mai ƙarfi na DC.

Wadannan su ne misalai masu mahimmanci da yawa:
1. Zazzabi yana rinjayar sakamakon ma'aunin wutar lantarki na DC.Idan yanayin zafi ya yi yawa, ruwan ɗigo zai yi girma da yawa.Lokacin da yawan zafin jiki na samfurin ke sarrafawa a 30-80, sakamakon gwajin ya fi kyau.Yayyo na yanzu yana canzawa a fili a cikin wannan kewayon zafin jiki.Ina buƙatar tunatar da cewa, musamman ma a cikin ƙananan yanayin zafi, idan sakamakon gwajin ya kasance Rashin haƙuri yana da tsanani sosai, muna buƙatar yin la'akari da tasirin yanayin zafi, kuma ba za mu iya yanke hukunci kawai ga gazawar ko lalacewar gwajin ba. samfur.
2. Tasirin ruwan ɗigon saman na yanzu A haƙiƙanin gaskiya, idan ruwan yayyan ya rabu, ana iya raba shi zuwa ƙarar ƙyalli na halin yanzu da na yanzu.Girman ɗigogin saman na yanzu ya dogara da tasirin danshi akan farfajiyar waje na samfurin gwajin.Tsaftace saman samfurin, bushe shi idan ya cancanta, ko haɗa zoben garkuwa, wanda zai iya guje wa ɗigon ruwa mai yawa yadda ya kamata.Bugu da kari, gwajin yabo na DC ta hanyar amfani da janareta na babban wutar lantarki na DC shine don yin nazari sosai kan abin da aka gwada ta hanyar girman leakawar halin yanzu, canjin ɗigogi a yayin ci gaba da haɓakawa, da kwanciyar hankali na yanzu lokacin gwajin. ƙarfin lantarki ya kai ƙimar ƙima.Rufin samfurin yana da kyau ko mara kyau.Gwajin jurewar wutar lantarki na DC shine yin hukunci akan ko kayan da aka haɗa sun cancanta ko a'a ƙarƙashin ƙayyadadden lokaci da ƙayyadaddun ƙarfin lantarki, kuma kayan insulating ba a karye ba kuma ko akwai walƙiya.
Gwajin high-voltage da kansa gwaji ne mai lalata, amma wannan gwajin na iya samun lahani waɗanda ba za a iya samun su a cikin gwaje-gwajen da ba su lalata ba, musamman idan akwai ƙananan kumfa da lahani marasa shiga cikin rufin.Rashin lahani shi ne cewa zai haifar da wasu lahani ga abin rufe fuska yayin gwajin.Wannan yana buƙatar ƙarfin gwajin fitarwa don amfani da abubuwan gwaji daban-daban daidai da buƙatun cikin ƙa'idodi.
Gwajin jurewar wutar lantarki na DC shine yin hukunci akan ko kayan da aka haɗa sun cancanta ko a'a ƙarƙashin ƙayyadadden lokaci da ƙayyadaddun ƙarfin lantarki, kuma kayan insulating ba a karye ba kuma ko akwai walƙiya.Gwajin high-voltage da kansa gwaji ne mai lalata, amma wannan gwajin na iya samun lahani waɗanda ba za a iya samun su a cikin gwaje-gwajen da ba su lalata ba, musamman idan akwai ƙananan kumfa da lahani marasa shiga cikin rufin.Rashin lahani shi ne cewa zai haifar da wasu lahani ga abin rufe fuska yayin gwajin.Wannan yana buƙatar ƙarfin gwajin fitarwa don amfani da abubuwan gwaji daban-daban daidai da buƙatun cikin ƙa'idodi.
Lokacin aikawa: Afrilu-20-2022