GD-2134E babban tsari ne na gano bututun ƙarfe na ƙasa wanda ya ƙunshi masu watsa sigina da masu karɓa.Ana iya amfani da shi don gano hanya, binciken bututun mai da zurfin auna bututun ƙarfe da igiyoyi na ƙasa.Yana iya aiwatar da ganewa na musamman tare da na'urorin haɗi iri-iri da aka zaɓa, da kuma lalata rufin bututu da kuma neman wasu nau'ikan kuskuren na USB.
●Nunin Compass: da fahimta yana nuna wurin bututun da hagu & kwatance.
●Bin sawun gaskiya da karya: ma'aunin shugabanci na yanzu, bin diddigin kuskuren kuskure, kawar da tsangwama (wasu mitoci).
●Zurfi da ma'auni na yanzu, na iya nuna ƙarfin siginar lanƙwan tarihi.
●Cikakken ingantaccen samfur na dijital na dijital: tsayayye kuma abin dogaro, matsananciyar hankali, kunkuntar karɓar fasfo, ƙarfin hana tsangwama, na iya cika jujjuya mitar wutar lantarki da tsangwama cikin jituwa na igiyoyi masu gudana da bututun da ke kusa.
●Gano na USB mai gudana: maɗaɗɗen watsawa mai girma, matsakaicin siginar fitarwa zuwa kebul mai gudana.
●Kebul/ganewar bututu: Matsala masu sassauƙa (na zaɓi) suna da sauƙin amfani kuma suna ba da sakamakon ganowa a sarari;stethoscopes (na zaɓi) ana iya amfani dashi lokacin da bai dace ba don amfani da matsi.
●Gano kuskuren ƙasa: Mai haɓaka HV (na zaɓi) yana haɓaka matsakaicin ƙarfin fitarwa zuwa 1000V, yana amfani da firam ɗin A (na zaɓi) don gano wuraren fashewar ƙasa na bututun, babu buƙatar daidaita sifili.Kibiya tana nuna alkiblar wurin kuskure.
●Mitar ganowa da yawa: gano aiki da gano m.
●Fitowar sigina iri-iri na mai watsawa: fitowar haɗin kai kai tsaye, fitarwar haɗin gwiwa, shigar da hasken wuta.
●Babban ƙarfin fitarwa na watsawa, fitarwa mai yawa daidaitacce, daidaitaccen impedance ta atomatik da kariya.
●Gina rukunin batir lithium ion babban ƙarfin aiki, zai rufe ƙarancin wutar lantarki ta atomatik ko kuma na dogon lokaci ba aiki,
●Harka mai karko, haske kuma mai ɗaukuwa.
Mai watsawa
●Hanyoyin fitarwa: fitarwar haɗin kai kai tsaye, shigarwar radiation, fitarwar haɗin gwiwa (na zaɓi), kuskuren gano mai haɓaka HV (na zaɓi).
●Mitar fitarwa: 640Hz (mitar haɗin gwiwa), 1280Hz (mitar haɗin gwiwa), 10kHz, 33kHz, 82kHz, 197kHz.
●Ƙarfin fitarwa: Max.10W, 10 gears daidaitacce, daidaitaccen impedance ta atomatik.
●Haɗin kai tsaye ƙarfin lantarki na fitarwa: matsakaicin 150Vpp.
●Yajin aiki da gajeriyar kariya.
●Man-inji dubawa: 320 x240 dige matrix LCD nuni.
●Batir da aka gina: 4 sashe 18650 batirin lithium ion baturi, 7.4V mara kyau, 6.8Ah.
Mai karɓa
●Yanayin shigarwa: Ginin na'ura mai karɓa, mai sassauƙa manne akan CTs(na zaɓi), Stethoscope(na zaɓi), Na'urar gano kuskuren nau'in(na zaɓi).
●Karɓar mitar:
Mitar ganowa mai aiki don Bututu: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
Mitar gano mitar wutar lantarki: 50Hz/60Hz da 250Hz/300Hz (mai daidaita mai amfani).
Mitar gano m RF: mitar cibiyar ita ce 10kHz, 33kHz, 83kHz bi da bi.
●Yanayin gano bututu: Hanyar kololuwa mai faɗi, ƙunƙuntacciyar hanyar kololuwa, Hanyar kwarin sauti.
●Yanayin gano kebul: m manne-kan CTs (na zaɓi) ganewa ta atomatik da ma'auni na yanzu, stethoscope (na zaɓi) ganewa.
●320 * 240 LCD nuni, yana nuna girman sigina, jagorar hagu / dama, daidai / nunin ƙarya, yanayin tarihin ƙarfin siginar, zurfin, halin yanzu da sakamako.
●Batir da aka gina a ciki, 2 sashe 18650 baturin lithium ion baturi, 7.4V, 3.4Ah.
Wasu
●Girma: Mai watsawa 280*220*90mm.Mai karɓa 680*270*120mm.
●Nauyi: Mai watsawa 2.2kg.Mai karɓa 3.5kg.
●Caja: shigarwar AC100-240V, 50/60Hz, fitarwa DC 8.4V,2A/3A.
●Yanayin aiki: Zazzabi -10-40 ℃, Humidity 5-90% RH, tsayi <4500m.
Mai watsawa
![]() | ![]() |
| Mai watsawa gabaɗaya | Allon madannai mai watsawa |
| 1. LCD nuni 2. Allon madannai 3. soket na fitarwa 4. Cajin soket | 5. KUNNA / KASHE 6. Maɓallin sake fitarwa 7/8.Maɓallin rage / ƙara ƙarfin fitarwa 8/9.Maɓallin raguwa/ƙara mitoci |
Mai karɓa
![]() |
|
| Mai karɓa gabaɗaya | Allon madannai mai karɓa |
| 1. LCD nuni 2. Allon madannai 3. Samun daidaitawaingdunƙule 4. Cajin soket 5. Na'urar shigar da soket | 6. Maɓallin Sauyawa/Barewa 7. Maɓallin yanayi 8. Maɓallin rage mita 9. Maɓallin ƙara yawan mita 10. Maɓallin daidaitawa 11. Maɓalli mai aunawa |
Daidaitaccen kayan haɗi
| A'a. | Suna | Zane-zane da umarni | Qty |
| 1 | Kebul na haɗin fitarwa na watsawa | ![]() | 1 |
| 2 | rawar ƙasa | ![]() | 2 |
| 3 | Layin tsawo na ƙasa | 1 | |
| 4 | Caja | Tmisali, watsawakumadole ne a caje mai karɓa daban | 2 |
Na'urorin haɗi na zaɓi (Kayyade lokacin yin oda, tsoho da ba a bayyana ba)
| A'a. | Suna | Zane-zane da umarni | Magana |
| 1 | Chaɗin kebul don mai karɓana'urorin haɗi. | ![]() Blue 6-core plug | |
| 2 | Chaɗin kebul donna'urorin watsawa. | ![]() Red 5-core toshe | |
| 3 | Manne-kan CT don watsawa | ![]() | |
| 4 | CT mai sassauƙa don mai karɓa | ![]() | |
| 5 | Afiram | ![]() | |
| 6 | Gano kuskure HV mai kara kuzari | ![]() | |
| 7 | Ƙananan stethoscope | ![]() | |
| 8 | Dogon kara stethoscope | ![]() | |
| 9 | Gano sanda don la kan kara stethoscope | ![]() |