GDCR-3200C Mai Gwajin Juriya na Duniya Mai Maɗaukaki Biyu
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester an ƙera shi musamman kuma an ƙera shi don auna juriya na ƙasa, juriya na ƙasa, ƙarfin ƙasa, haɓakar layin ƙasa na yanzu, AC halin yanzu da juriya na DC.Kayan aiki yana ɗaukar fasahar sarrafa dijital ta ci gaba, tare da hanyar 2-waya, hanyar 3-waya, hanyar waya ta 4, hanyar zaɓi, hanyar matsawa biyu da sauran hanyoyin aunawa;Shigo da fasahar FFT (Fast Fourier Transform), fasahar AFC (Automatic Frequency Control), tare da keɓaɓɓen ikon hana tsangwama da daidaitawar muhalli, babban maimaita gwajin gwajin, yana tabbatar da daidaito mai girma, babban kwanciyar hankali da babban dogaro ga ma'auni na dogon lokaci.Kayan da aka yi amfani da su. babban ma'aunin matsi na yanzu, yana iya magance kowane nau'ikan buƙatun gwaji, na iya auna ƙimar juriya ta ƙasa na babban girman ƙasa ƙasa gubar, mai sassauƙa mai auna ƙimar juriya na ma'ana guda da grid grounding da kowane nau'in tsarin ƙasa mai rikitarwa, babu buƙatar cire haɗin duk wani igiya mai alaƙa da layi ɗaya lokacin auna tsarin tsarin ƙasa, yana inganta sauƙin aunawa sosai, don gwajin aikin ƙasa yana ba da cikakkiyar mafita.
GDCR3200C Double Clamp Multifunctional Earth Resistance Tester ya ƙunshi na'ura mai watsa shiri, matsi na yanzu (matsi biyu), wayoyi na gwaji, sandar ƙasa mai taimako, software na bayanai da wayoyin sadarwa da sauransu.Babban nunin LCD na na'ura mai watsa shiri tare da farar hasken baya da nunin jadawali wanda za'a iya gani a sarari.Mai gwadawa yana da aikin ajiya, aikin agogo, kuma ta atomatik tana adana ƙungiyoyin 2000 na sakamakon gwaji mai ɗauke da kwanan wata da lokaci. Mai gwadawa tare da aikin sadarwar Bluetooth yana goyan bayan tsarin Android.Bayan shigar da APP, zai iya gwadawa ko karanta bayanan gwaji a cikin tashar wayar hannu, yana kawo sabon ƙwarewa.Mai gwadawa yana ba da kebul na USB, kuma ana iya loda bayanan da aka adana zuwa PC ta hanyar kebul na USB.Software na sadarwa na iya gane ayyukan karatu, tuntuɓar juna, adanawa, bayar da rahoto da buga bayanan rikodin tarihi.Ana amfani da shi sosai a cikin wutar lantarki, sadarwa, yanayin yanayi, filayen mai, gini, kariyar walƙiya da kayan lantarki na masana'antu.
●Zane na musamman na hasken alamar jack, daidaitaccen nuni na matsayi na jack, kauce wa kuskuren aiki.
●Kullin zaɓin aikin Gears, ana nuna hanyoyin gwaji iri-iri, suna sa aikin ya zama mai sauƙi da sauri.
●Mai gwadawa yana da aikin sadarwar Bluetooth kuma yana goyan bayan tsarin Android.Masu amfani za su iya amfani da tashar wayar hannu don gwada aiki ko karanta sakamakon gwaji mai ɗauke da kwanan wata da lokaci cikin dacewa.
●Kayan kayan aiki yana ɗaukar akwatin kariya mai hana ruwa, wanda yake da ƙarfi, aminci kuma mai dorewa don rigakafin karo, rigakafin faɗuwa da hana ruwa (matakin kariya IP65), musamman dacewa don amfani a wuraren gini na waje.
●Mitar tana sanye da babban fakitin baturin lithium mai iya caji.Kuma tare da kebul na USB don loda aikin bayanai.
Abubuwan asali & Yanayin Aiki
| Tasiri Yawan | Tushen Yanayi | Yanayin Aiki | Magana |
| Yanayin yanayi | 23℃±1℃ | -10 ℃ - 40 ℃ | ---- |
| Humidity na yanayi | 40% -60% | <80% | ---- |
| Aiki Voltage | 7.8V± 0.1V | DC 7.8V± 0.6V | ---- |
| Resistance Duniya na taimako | <100Ω | <5k ku | |
| Tsangwama Voltage | Kamata ya guje | <20V | |
| Tsangwama Yanzu | Kamata ya guje | <2A | |
| Distance Electrode lokacin aunawa R | a:5d | a:5d | |
| Distance Electrode lokacin aunawa ρ | a:20h ku | a:20h ku |
Gabaɗaya ƙayyadaddun bayanai
| Aiki | Auna juriya na ƙasa, juriya na ƙasa;juriya na DC, wutar lantarki ta duniya, madaidaicin halin yanzu, yayyo halin yanzu | |
| Tushen wutan lantarki | DC 7.4V 2600mAh baturi lithium mai caji, cike da kusan 8.4V | |
| Hasken baya | Hasken baya na allo mai sarrafawa, dace da wurare masu duhu | |
| Hanyar aunawa | juriya na DC | Hanyar juriya ta DC 2-waya |
| Hanyar juriya ta DC 4-waya | ||
| Juriya ta duniya | Hanyar juriya ta duniya 2-waya | |
| Hanyar juriya ta duniya 3-waya | ||
| Hanyar juriya ta duniya 4-waya | ||
| Juriya na duniya hanyar matse guda 3-waya (hanyar zaɓi) | ||
| Juriya na duniya hanya guda 4-waya (hanyar zaɓi) | ||
| Duniya juriya doubhanyar matsawa | ||
| Ƙarƙashin ƙasa (Hanyar Wenner) | ||
| Duniya halin yanzu | Ma'aunin manne na yanzu | |
| Wutar lantarki ta duniya | Matsakaicin gyarawa | |
| Gwajin Wutar Lantarki | Tashin hankali | |
| Yawan Gwaji | 128Hz/111Hz/105Hz/94Hz(AFC) | |
| Gwajin gajeren kewayawa Yanzu | AC 250mA max | |
| Gwajin Buɗaɗɗen kewayawa Yanzu | AC 40V max | |
| Tsawon Nisa na Electrode | 1m-100m | |
| Yanayin Nuni | 4-dijital babban LCD nuni, tare da allon baya | |
| Alamar Aunawa | Lokacin aunawa, alamar filasha LED, nunin ƙidayar LCD | |
| Girman Frame LCD | 128mm × 75mm | |
| Wurin nunin LCD | 124mm × 67mm | |
| Girman Kayan aiki | 280mm(L) x 260mm(W) x 160mm(H) | |
| Girman CT | 223mm x 120mm x 39mm | |
| Gwajin Waya | 4 wayoyi: kowanne don ja 20m, baki 20m, rawaya 10m, da kore 10m | |
| Sauƙaƙe Waya Gwaji | 2 wayoyi: kowanne don ja 1.6m da baki 1.6m | |
| Ƙarƙashin Ƙarƙashin Ƙarfafawa | 4PCS: Φ10mm x150mm | |
| Matsi na Yanzu | 2PCS: 1 blue-black plug da 1 ja-baki toshe | |
| Matsa Caliber | Φ70mm | |
| Matsa Gubar Waya | 2m | |
| Adadin Aunawa | AC halin yanzu: kusan sau 2/dakika | |
| Wutar Lantarki ta Duniya: kusan sau 2/dakika | ||
| Juriya na duniya: kusan 7 seconds/lokaci | ||
| Lokacin Aunawa | Sama da sau 5000 (Gwajin gajeriyar kewayawa, lokacin tazara ya zama aƙalla daƙiƙa 30) | |
| Layin Voltage | Auna kasa da AC 600V | |
| Sadarwar Sadarwa | Na'urar Bluetooth, kebul na USB, bayanan ajiya ana iya loda su zuwa kwamfuta, adanawa ko buga su. | |
| Wayar Sadarwa | Kebul na sadarwa waya x1pcs, tare da tsawon 1.5m | |
| Riƙe Data | Ayyukan riƙe bayanai: nunin alamar "HOLD". | |
| Adana Bayanai | Ƙungiyoyi 2000, "MEM" alamar ajiya, "FULL" alamar filashin nunin ajiya ya cika | |
| Samun Data | Ayyukan karanta bayanai: nunin alamar "KARANTA". | |
| Nuni mai wuce gona da iri | Wuce aikin auna yawan kewayo: "OL" nunin alamar | |
| Low alamomi na yanzu | Aunawa tare da hanyar zaɓi ko matsi sau biyu, siginar da CT2 ke karɓa a halin yanzu tana ƙasa da 0.5mA, zai nuna "", kuma yakamata ya duba jagorar matsawa na CT2 na yanzu. | |
| Gwajin Tsangwama | Gano siginar tsangwama ta atomatik, alamar “NOISE” nuni lokacin da ƙarfin kutse ya fi 5V | |
| Gwajin Grounding Auxiliary | Tare da aikin gwajin juriya na ƙarin ƙasa, 0.00KΩ-30kΩ(100R+rC <50kΩ, 100R+rP <50kΩ) | |
| Ayyukan ƙararrawa | Ƙimar aunawa ta wuce ƙimar saitin ƙararrawa, zai fitar da sautin ƙararrawa "Toot-toot-toot". | |
| Wutar Batir | Yayin da ƙarfin baturi ya ragu zuwa kusa da 7.2V± 0.1V, zai nuna alamar ƙarancin ƙarfin baturi, da tunatarwa don maye gurbin baturin. | |
| Rufewar atomatik | Kashe ta atomatik bayan kunna wuta na mintuna 15 | |
| Aiki Yanzu | Hasken baya: 25mA Max (yawan amfani da hasken baya kawai) | |
| Jiran aiki:25mA Max (hasken baya bayan an kunna) | ||
| Aunawa: 150mA Max (kashe hasken baya) | ||
| Nauyi | Gwajin: 2290g | |
| Matsala na yanzu: 1100g (2pcs) | ||
| Jimlar nauyi: 6800g (hada da duk kayan haɗi) | ||
| Yanayin Aiki & Humidity | -10 ℃-40 ℃, kasa da 80% rh | |
| Yanayin ajiya & zafi | -20 ℃-60 ℃, kasa da 70% rh | |
| Matsayin Kariya | IP65 (rufe akwati) | |
| Kariya fiye da kima | Auna juriyar ƙasa: tsakanin kowace musaya na C (H) -E,P(S)-ES, AC 280V/3 seconds | |
| Juriya na Insulation | Sama da 20MΩ (tsakanin kewaye da harsashi na waje shine 500V) | |
| Jurewa Voltage | AC 3700V/rms.(Tsakanin kewayawa da harsashi na waje) | |
| Features na Electromagnetic | IEC61326 (EMC) | |
| Nau'in Kariya | IEC 61010-1 (CAT Ⅲ 300V,CAT IV 150V,Gurbacewa 2); IEC61010-031; IEC61557-1 (Juriya ta Duniya); IEC 61557-5 (ƙasar ƙasa); JJG 366-2004 (Mita juriya) JJG 1054-2009 (Mitar juriya na ƙasa) | |