GDPD-3000C Mai Gano Sashe Mai Rarraba
GDPD-3000C Portable Ultrasonic Partial Discharge Detector yana amfani da na'ura mai kwakwalwa ta girgije da fasaha ta atomatik don cimma ma'aunin siginar fitarwa, rikodi, watsawa, ajiya, bincike da musayar, samar da goyon baya na fasaha mai karfi don aunawa a kan-site na fitarwa.Ma'aikatan aunawa suna tattara bayanan fitarwa ta wani ɓangare ta amfani da GDPD-3000C, kuma ana iya amfani da na'ura mai kwakwalwa don gano yanayin rufewar kayan aikin ganowa a cikin ainihin lokaci.
Hardware
●Processor: high yi na fasaha processor.
●Allon: 4.3inch Touch Screen.
●Maɓallin aiki: PVE film keyboard.
●Interface:
●3.5mm na'urar kai ta sitiriyo
●DC LV na caji na yanzu
●USB 2.0 3G mara waya ta hanyar sadarwa
●TF katin ƙwaƙwalwar ajiya
●Fitar firikwensin bincike na waje
●TF katin ƙwaƙwalwar ajiya: 4G-32G.
●Wayoyin kunne: Min.8Ω.
●Binciken waje: layin tsawo na bincike na Ultrasonic 250mm.
●Abubuwan da aka haɗe: ABS+ PC Plastique.
●Nauyin: 0.7kg;
●Girma: 241*126*189mm
Yanayin Aiki
●Yanayin aiki: 0 ~ 55 ℃.
●Aiki zafi: 0 ~ 90% RH, ba condensing.
●Adireshin IP: 54.
Ma'aunin Sensor na Ultrasonic
●Ma'auni: -20dBµV~65dBµV.
●Matsakaicin: 1dB.
●Daidaito: ± 1dB.
●Hankali: -65dB.
●Mitar: 40kHz.
●Diamita: 16mm.
●Tushen gwaji: 25dB ~ 35dB.
Ma'aunin TEV
●Sensor: Capacitive.
●Ma'auni: 0dBµV~60dBµV.
●Matsakaicin: 1dB.
●Daidaito: ± 1dB.
●Matsakaicin adadin Pulses/Cycle: 655.
●Min adadin bugun jini: 5 Hz
Tushen wutan lantarki
●Baturi na ciki: 3.7V, 5.6Ah Lithium-ion mai caji.
●Yawancin lokacin aiki: kusan.6 hours.
●Kariyar baturi: Lokacin rufewa ta atomatik, tsoho mintuna 10.
●Ƙididdigar ƙarfin lantarki na caja: 90-264V AC.
●Yin cajin wuta / na yanzu: 5V/2.4A.
●Lokacin Caji: kusan.awa 9.