GDWG-V SF6 Gas Leak Detector (nau'in IR, nuni sau biyu)
GDWG-V SF6 Gas Leak Detector is infrared ja irin leak detector (NDIR fasaha) tare da biyu nuni.Yana da launi INCELL TFT nuni kuma ainihin lokacin yana nuna maida hankali SF6.Yana saurin gano mai fashewar SF6, madaidaicin magudanar GIS da ƙimar ɗigo na shekara daidai da ƙima.Na'ura ce mai kyau wacce ta dace da sashin samar da wutar lantarki, shigarwa da juzu'i, cibiyar gwajin wutar lantarki.
●Babban Kayan Aikin Canja Wuta
●Rotor vane na helikwafta
●Tsarin watsa iskar gas
●Don gano abin kashe gobara
●Binciken ingancin iska na Gine-gine
●Don gano haɗari
●Babu radiation.
●Babu buƙatar maye gurbin high matsa lamba high tsarki argon gas akai-akai.
●Babu buƙatar kusanci iskar gas mai ƙarfi.
●Babu buƙatar maye gurbin na'urori masu auna firikwensin akai-akai, mai tsada.
●Tsayayyen aiki, ƙarancin kulawa.Babu buƙatar yin ƙirar layi a kowace shekara.
●Babu wani tasiri da danshi da gurbacewar yanayi.
●Babban hankali, har zuwa 0.01ppmv.
●Lokacin da yayyo mai tsanani ko SF6 iskar gas ya kai 100%, ba za a ƙazantar da shi ko lalacewa ba.
●Launi TFT In-Cell, nuni biyu, na gani a cikin hasken rana.
●Batirin lithium da aka gina a ciki.
●Ƙararrawar mai amfani da sauti da haske.
●Babban hankali da kwanciyar hankali mai kyau.
●Saurin aunawa, lokaci ya kai 3s.
●Matsakaicin zafin jiki da ramuwa.
●Amsa kawai don SF6 gas, ba don sauran gas ba.
●Siffofin ma'aunin ma'auni mara iskar gas suna tabbatar da cewa babu gubar firikwensin da zai faru a kowane taro.
●Wurin zafin jiki na firikwensin zai iya tabbatar da cewa firikwensin ba shi da motsin zafin jiki a kowane zafin yanayi.
●Ƙananan girman, sauƙin ɗauka, dace da aiki a kan shafin.
●Tare da jakar gas ba zamewa ba, mafi dacewa don ɗauka.
●Adana bayanai har zuwa ƙungiyoyi 100.
●Super-haske aluminum tare da cikakken garkuwa harsashi.
●Kunshin waje yana amfani da filastik injiniya, tare da hana ruwa, ƙura.
●Ƙa'idar aunawa: firikwensin infrared mara tarwatsawa (NDIR)
●Ma'auni: 0-2000ppmv SF6 ko 0-50ppmv
●Resolution: 0.1ppmv ko 0.01ppmv
●Daidaito: ± 2% FS (0-1000ppm)
●Kuskuren maimaitawa: ≤± 1%
●Hankali: 0.1ppmv
●Lokacin amsawa: ≤2s
●Lokacin farfadowa: ≤5s
●Kwanciyar hankali: ≤± 20ppm, fiye da 1000hours
●Canjin sifili: ≤± 1% (FS/shekara)
●Kuskuren layi: ≤± 1%
●Ma'ajiyar zafin jiki: -20~+60℃
●Yanayin aiki: -20 ℃ + 50 ℃
●Yanayin Samfura: Gina-ginen famfo diaphragm na lantarki, nau'in ramukan atomatik, gudana har zuwa 1L/min.
●Wutar lantarki mai aiki: 220VAC± 10%, 50Hz Ko Gina-in Li-batir, 8hours yana aiki.
●Girma: 160 × 220 × 70mm, gunkin hannu 106mm*170mm*120mm.
●Nauyi: babban sashi kamar 1.5kg, bindigar hannu kusan 0.5kg