HV-OWS-63 Oscillating Wave Test System (OWTS) don Kan-site PD Diagnostics of Cables
1. HV-OWS jerin wani hadedde part part gwajin gwaji tsarin, yafi amfani da partially sallama ganewar asali na matsakaici irin ƙarfin lantarki igiyoyi.Mitar gwajin tsarin shine 50Hz zuwa ɗaruruwan Hz damping AC ƙarfin lantarki, damping AC ƙarfin lantarki da aka samar da tsarin a lokacin da gwajin zai iya kai 60kV, kuma an hade shi da ci-gaba tsarin hardware da tsarin software don ganewar asali.
●Sabuwar fasahar wutar lantarki ta semiconductor
●Sabuwar fasahar sarrafa Laser
●Mai haɓaka siginar dijital da fasahar tacewa
●Babban fasahar sarrafa hanyar sadarwa mara waya.
2. Software na aunawa da bincike na iya yin nazarin bayanan nesa a ƙarƙashin yanayin hanyar sadarwa.
3. Cikakken tsarin aikin Ingilishi, mai iya yin rikodin oscillating ƙarfin lantarki waveforms da siginar siginar fitarwa na ɓangare, da kuma yin ɗigon lokaci na ainihi yayin aikin matsa lamba;
4. Nuna ta atomatik mita, amplitude da samfurin lokaci nisa na oscillating ƙarfin lantarki waveform.
5. Yana iya ta atomatik bincikar faɗaɗa waveform na siginar fitarwa da aka gwada.
6. Nuna ƙimar gwajin asarar dielectric ta atomatik.
7. Ƙirƙirar taswirar wurin fitarwa ta atomatik kuma samar da rahotannin ƙididdiga, kuma ta atomatik haifar da taswirar ƙididdiga na fitarwa ta atomatik.
Fitar wutar lantarki | Matsakaicin: ± 60kVkololuwa |
Mitar oscillation | 20Hz ~ 850Hz |
Inductance | 1.0H ~ 2.1H (na zaɓi) |
Binciken bayanai | Nazarin hannu, bincike ta atomatik (analog da tace dijital) |
Za a auna kewayon iya aiki | 0.05-5uF |
Babban cajin wutar lantarki | 10mA |
Kewayon gwajin fitarwa na juzu'i | 10pC ~ 200nC |
Daidaiton aunawa | ± 0.1pC (samfurin 14bits) |
Gudun igiyar ruwa | 50-300m/mu |
Gano daidaito | ± 0.1m |
Kuskuren ganowa | ≤1% × tsayin igiya |
Gano matakin PD | Dangane da IEC60270 |
PD gano bandwidth | 100kHZ ~ 50MHZ atomatik ko manual selection |
Dielectric asarar darajar tan δ | 0.1% ~ 10% |
Ƙarfin wutar lantarki | 180V ~ 250V, AC 50Hz |
Yanayin aiki | -120 ℃ ~ + 60 ℃ |
Nauyi | Kimanin 88kg |
Girman | Diamita 650mm, tsawo 980mm |
Interface | WLAN (IEEE802.11g) / 100M Ethernet katin |
A'a. | Suna | Qty |
1 | HV-OWS-63 oscillating tsarin gwajin igiyar ruwa babban naúrar | 1 saiti |
2 | Kwamfutar littafin rubutu (tare da ginanniyar gwajin juzu'i mai motsi da tsarin software na bincike) | 1 saiti |
3 | Capacitor diyya na waje | 1 saiti |
4 | Babban wutar lantarki bugun jini calibration janareta | 1 saiti |
5 | Babban ƙarfin lantarki gwajin na USB | 1 saiti |
6 | High-voltage connecting na USB (haɗin ramuwa capacitors) | 1 saiti |
7 | Calibration pulse generator na USB (ja daya da baki daya) | 2pcs |
8 | Sarrafa kebul na siye | 1pc |
9 | Kebul na sadarwa na hanyar sadarwa (tare da tashar tashar sadarwa zuwa nau'in-c module) | 1pc |
10 | Wayar ƙasa | 1pc |
11 | Sandar ƙasa | 1pc |
12 | Kebul na wutar lantarki | 1pc |
13 | Fakitin waya na kayan haɗi | 1pc |
14 | Littafin aiki | 1 kwafi |
15 | Takaddun shaida/katin garanti | 1 kwafi |
16 | Jerin kaya | 1 kwafi |