Na'urar gano makaman nukiliya ta zamani mara igiyar wuta mai ƙarfi tana da ƙaƙƙarfan aikin hana tsangwama, ya dace da ƙa'idodin (EMC), kuma ya dace da lokuta daban-daban na kutsawa filin lantarki.Ana fitar da siginar lokacin siginar babban ƙarfin lantarki ta mai tarawa, sarrafa shi kuma a aika kai tsaye.Ana karɓa ta kayan aikin lokaci kuma idan aka kwatanta da lokaci, kuma sakamakon bayan lokaci yana da inganci.Saboda wannan samfurin watsawar mara waya ne, yana da aminci da gaske, abin dogaro, sauri da daidaito, kuma ya dace da lokuta daban-daban.
Matakin shine muhimmiyar hanyar haɗin gwiwa a aikin injiniyan wutar lantarki.Na'urar zamani mara igiyar wuta mai ƙarfi shine kayan aikin zamani da aka yi amfani da shi, wanda yake haske, sauri kuma daidai.Gabaɗaya, lokacin da ake amfani da su, nau'ikan nau'ikan nau'ikan suna ƙarƙashin irin ƙarfin lantarki iri ɗaya, wanda babu shakka babu matsala.Baya ga tabbacin lokaci na al'ada a matakin ƙarfin lantarki iri ɗaya, ana iya amfani da na'urar tabbatar da lokaci mara igiyar wuta mai ƙarfi a cikin matakan ƙarfin lantarki!
GDHX-9500 mara waya ta high ƙarfin lantarki lokaci ganowa
Hanyar gwajin gano lokaci:
1. Hanyar daidaitawa na cikin gida
a.Fitar da mai watsawa X da watsa Y sannan ku haɗa sandar fitarwa (ginanne eriyar watsawa), sannan ku haɗa mai watsawa X da ƙugiya mai watsawa tare da ƙananan shirye-shiryen bidiyo guda biyu a ƙarshen layin gwajin da kayan aikin ke bayarwa.Bayan an toshe ƙarshen ɗaya a cikin wutar lantarki 220V (saboda 220V live waya mai hawa ɗaya ta canza zuwa waya mai rai biyu, ƙarfin lantarki yana da ƙasa), kunna wutar lantarki na mai karɓar.Bayan tsarin igiyar ruwa ya bayyana, ana iya ɗaukar kayan aiki na al'ada.
2. Amfani da kan-site
a.Kafin amfani, dole ne a bi ka'idodin aikin "Dokokin Gwaji don Kayayyakin Tsaron Wutar Lantarki".
b.Haɗa mai watsawa X da mai watsawa Y zuwa sandunan insulating bi da bi (tsawon tsayin sandunan insulating ya dogara da ƙarfin lantarki)
c.Kunna wutar lantarki na mai karɓar, kuma mai karɓa zai yi ta atomatik kuma ya nuna ma'aunin motsin igiyoyin X da Y.Nuna bambancin lokaci tsakanin matakan X da Y.(≤± 20 digiri ne a cikin lokaci,> 20 digiri ba su da lokaci) da kuma nuna a cikin lokaci ko waje.
Matakan kariya
1. Ayyukan kan-site dole ne su bi ka'idodin aikin "Ka'idodin Ka'idodin Tsarin Gwaji na Kayan Aikin Tsaro"
2. A guji amfani da masu watsa rediyo (walkie-talkies, da dai sauransu) a lokaci guda yayin amfani, don kar a tsoma baki tare da mai karɓa.