GD2000D Gwajin Juriya na Insulation
GD2000D gwajin juriya na dijital na dijital wanda kamfaninmu ya samar yana amfani da tsarin aiki na gaske na masana'antu guda ɗaya.Alamar analog na dijital da nunin filin filin dijital an haɗa su daidai.Wannan jerin mita yana da nau'ikan nau'ikan fitarwa na ƙarfin lantarki (250V, 500V, 1000V, 2500V, 5000V, 10000V), babban ƙarfin aiki, tsangwama mai ƙarfi, ma'aunin analog da nunin synchronous dijital, AC da DC dual-amfani, aiki mai sauƙi, Lissafin atomatik na alamomin rufi daban-daban (rabo na sha, index polarization), sakamakon ma'auni daban-daban tare da aikin saukar da wutar lantarki, da dai sauransu. Kayan aikin gwaji ne mai kyau don auna juriya na babban ƙarfin wutar lantarki, masu canza wuta, janareta, high- Motoci masu ƙarfin wuta, masu ƙarfin wuta, igiyoyin wuta, da masu kama walƙiya.
DL/T 474-2006 "Jagora don Gwajin Insulation akan wurin"
DL/T 845-2004 "Gabaɗaya dalla-dalla don auna juriya kayan aiki"
DL/T 846-2004 "Babban ƙayyadaddun ƙayyadaddun fasaha don kayan gwajin ƙarfin lantarki"
DL/T 596-2005 "Lambar gwajin rigakafi don kayan wutar lantarki"
GB50150-2006 "Standard don gwajin hannun hannu na kayan aikin lantarki na shigarwa injiniyoyi"
GB/T16927.1 ~ 2-1997 "Hanyoyin gwajin ƙarfin lantarki"
GB4793-1984 "Haɗin kai don ingantaccen watsa wutar lantarki da kayan rarrabawa"
1. Ƙimar wutar lantarki (250V / 500V / 1000V / 2500V / 5000V) . Tsawon juriya 0-200GΩ.
2. Hanyoyi biyu suna nuna juriya na rufi.
3. Atomatik lissafin sha rabo da polarization index.
4. Ayyukan abokantaka, ci gaba da adana sakamakon ma'auni na 19 sau.
5. Auto-fitarwa saura high ƙarfin lantarki bayan gwajin ne a kan.
6. AC/DC wutar lantarki, tare da cajin baturi ko AC adaftan.
7. Ƙarfin ƙarfin tsangwama mai ƙarfi, kwanciyar hankali da ingantaccen karatu.
8. Zane mai ɗaukar hoto, dacewa da aikin daji.
9. Short-Circuit halin yanzu ≥3mA, kayan aiki mai kyau don gwada juriya na juriya na babban mai canzawa, inductor, janareta, injin HV, wutar lantarki, igiyoyi da mai kamawa.
| Abu Na'a. | Saukewa: GD2000D | ||||||
| Fitar wutar lantarki | 250V DC | 500V DC | 1000V DC | 2500V DC | 5000V DC | ||
| Daidaito | Zazzabi | 23℃±5℃ | |||||
| Juriya na rufi | 250-5G ± 5) | 50-10G ± 5) | 1M-20G ± 5) | 2.5M-50G ±5) | 5M-100G ±5) | ||
| Sauran kewayon: ± 10) | |||||||
| Fitar wutar lantarki | 2M-10G ± 5) | 4M-20G ± 5) | 8M-40G 0--+10) | 20-100GΩ 0 --+10) | 40-200G 0-- +10) | ||
| Short-circuit halin yanzu | ≥3mA | ||||||
| Tushen wutan lantarki | 8*Nau'in AA babban ƙarfin cajin baturi & adaftar waje | ||||||
| Yanayin Aiki & Humidity | -10 ℃ - 40 ℃, max. dangi zafi 85) | ||||||
| Ma'ajiya Temp. & Danshi | -20℃--60℃,max.dangi zafi 90) | ||||||
| Insulation | Max.2000MΩ lokacin da ƙarfin lantarki tsakanin kewaye da harsashi shine 1000VDC. | ||||||
| Juriya irin ƙarfin lantarki | Yi tsayin mintuna 1 lokacin da wutar lantarki tsakanin kewayawa da harsashi ke3kV50Hz SineWutar lantarki ta AC | ||||||
| Girma | 230mm*190mm*90mm (L*W*H) | ||||||
| Nauyi | 3kg | ||||||
| Gwajin juriya na rufi | 1 saiti |
| Gwada waya | 1 guda |
| Adaftar wutar lantarki | 1 guda |
| Igiyar wutar lantarki | 1 guda |
| Jagorar mai amfani | 1 kwafi |
| Takaddun shaida | 1 kwafi |