GDBT-8610P Gwajin Ƙarfin Batir
GDBT-8610P Ana amfani da Gwajin Baturi sosai a wurare masu zuwa:
●Telecom: Babban Ofishin, cibiyoyin sarrafa bayanai da Rubutun nesa
●Mai amfani da wutar lantarki: Sauyawa, Tashar Wuta da Wutar Lantarki
● Cibiyoyin Kuɗi: Cibiyoyin Bayanai na Ƙungiya
● Petrochemical: Tsarukan Gudanar da Tsari
●Tsarorin dake cikin teku
●Gwamnati: Karamar hukuma da yanki
●Cibiyoyin sarrafa Haraji da Haraji
● Tsaron Gida, Makarantu, Sojoji da Navy
●Kayan aikin sojan sama, Hukumomin kashe gobara da na 'yan sanda
● Tsarin UPS na asibiti
●Masu samar da motocin lantarki
●SLA baturi ƙera
● Gwajin gwaji mai faɗi: 5 ~ 6000Ah, mai dacewa da tantanin halitta guda ɗaya na 1.2V, 2V, 6V da 12V
●Smart da šaukuwa na'urar hannu, mai karko kuma mai saukin tafiya
●Allon taɓawa mai launi tare da ayyuka na zaɓi na madannai
●A lokaci guda gwada ƙarfin lantarki, juriya da ƙimar ƙima na batura
●Aunawar kan layi, babu buƙatar cire baturi da kirtani daga tsarin sa don gwaji, aminci da dacewa
● Gwaji mai sauri don baturi da kirtani a cikin daƙiƙa tare da gwajin adana bayanai ta atomatik
● Ƙarfafa tsangwama a cikin babban halin yanzu tare da kwanciyar hankali da ingantaccen aiki
● Gwajin mitar ƙasa da 10 Hz, yadda ya kamata ku guje wa tsangwama daga juriyar ƙarfin baturi kanta
●Madaidaicin kebul na USB don sabunta software da canja wurin bayanai zuwa PC don ƙarin nazari
●Mai sarrafa software mai ƙarfi na PC, dacewa don adana bayanai da nazari
●Babban ƙwaƙwalwar ajiya don gwada ajiyar bayanai na fiye da 3000 sel
●Ayyukan ƙararrawa na ƙararrawa da kan kariyar ƙarfin lantarki, amintaccen amfani
●Aikin daidaitawa ta atomatik kafin gwaji, haɓaka daidaiton gwaji
●Sake gwadawa da aikin ramuwa: duk wani aiki mara kyau ko tsallakewa ana iya gwada shi kawai tare da dannawa ɗaya
●Bayanan da aka ambata a cikin ƙwaƙwalwar ajiya don kwatancen gwajin ku, kuma ana samun ƙimar ma'anar ma'anar kai
Kewayon juriya | 0.00mΩ ~ 100mΩ | Wutar lantarki | 0.000V ~ 16V* |
Min ƙudurin gwaji- ƙarfin lantarki -juriya
| 1mv 0-999μΩ: 1 μΩ 1-9mΩ: 10μΩ(0.01mΩ) 10-99mΩ: 100 μΩ(0.1mΩ) | Gwajin daidaito - ƙarfin lantarki - juriya
| ± 0.2%rdg ± 6dgt 0μΩ-250μΩ: 8% ± 6DGT 250μΩ-500μΩ: 3%± 6DGT 500μΩ-100mΩ: 1%± 6DGT |
Tushen wutan lantarki | 7.2V 2400mAhBatirin Li-ion | Lokacin aiki | Fiye da awanni 5 bayan cikar caji |
Aunawa ƙwaƙwalwar ajiyar bayanai | Kwayoyin 3000 | Yanayin aiki | 0 ℃ zuwa 40 ℃90% RH |
LCD nuni | 320*240 pixel TFT allon taɓawa | Girma(babban rukunin) | L210*W110*H60mm |
Cikakken nauyi(kunshi) | 2 kg | Com tashar jiragen ruwa | Mini USB |