GDJB-1200A Saitin Kariyar Relay na Mataki Shida
●Fitar har zuwa 6-lokaci irin ƙarfin lantarki 6-lokaci halin yanzu, wanda za a iya hade don gane al'ada 4-lokaci irin ƙarfin lantarki 3-lokaci irin halin yanzu irin, 6-lokaci irin ƙarfin lantarki irin, 6-lokaci halin yanzu irin, da 12-lokaci fitarwa yanayin.
●Kwamfuta mai kula da masana'antu mai girma da 8.4-inch babban allon babban launi mai launi TFT ruwa mai mahimmanci, wanda zai iya samar da bayanai masu mahimmanci da ƙwarewa, ciki har da halin yanzu na aiki na na'urar, shawarwarin aiki na gaba da bayanin taimako daban-daban;
●Fitowar tana amfani da madaidaicin aminci, babban abin dogaro na madaidaicin madaurin wutar lantarki maimakon na'urar ƙara ƙarfin nau'in canji don babban aiki.Ba zai haifar da tsangwama mai tsayi da matsakaicin mita zuwa wurin gwajin ba, kuma zai tabbatar da ingantaccen motsin motsi da daidaito daga babban halin yanzu zuwa ƙaramin halin yanzu.
●Sashin fitarwa yana sarrafawa ta DSP, wanda ke da saurin lissafin sauri, ƙarfin sarrafa siginar dijital na ainihin lokaci, bandwidth watsawa da babban ƙudurin D / A.Siffar igiyar igiyar ruwa tana da madaidaicin madaidaici, ƙaramin murdiya da kyakkyawan layi.Yana ɗaukar babban adadin ci-gaba fasahar da madaidaicin kayan kayan, kuma ya aiwatar da ƙwararrun ƙira.Sabili da haka, na'urar tana da ƙananan girman, haske a nauyi, cike da aiki, mai sauƙin ɗauka, kuma ana iya sarrafa shi da zarar an fara farawa, kuma gwajin ya dace sosai.
●Zai iya kammala babban adadin babban aikin tabbatarwa mai rikitarwa tare da babban matakin sarrafa kansa.Yana iya sauƙi gwadawa da bincika saitunan kariya daban-daban, yin sake kunnawa kuskure, adana bayanan gwaji a ainihin lokacin, nunin zane-zane, da buga rahotanni akan layi.
●Akwai mai zaman kanta 110V da 220V sadaukar da daidaitacce fitarwa ikon DC don dubawa kan-site.
●Sabbin gwajin GDJB-1200A yana sanye take da buɗewa ta hanyar 10 da buɗewa ta 8, wanda ya dace da gwajin allurar kai.Alamar shigarwa ta dace tare da maras kyau lamba da 0 ~ 250V masu yuwuwar lambobi, waɗanda za a iya ganewa da hankali kuma ta atomatik.
●Zai iya yin ayyuka daban-daban masu rikitarwa, kuma yana iya gwadawa da bincika saitunan kariya daban-daban don sake kunnawa kuskure.Ajiye bayanan gwaji a ainihin lokacin, nunin zane-zanen vector, rahotannin buga, da sauransu.
●An tsara tsarin zubar da zafi da kyau, matakan kariya na kayan aiki suna da aminci kuma cikakke, kuma ana ba da aikin farawa mai laushi, software na kai-da-kai da aikin hana fitarwa.
| Fitar da AC na yanzu | Mataki na 6 (RMS) | 6*0-30A |
| Mataki na 3 (RMS) | 3*0-60A | |
| 6-phase parallel current fitarwa (RMS) | 0 ~ 180A | |
| Ƙimar aiki na tsawon lokaci mai izini na halin yanzu (RMS) | 10 A | |
| Matsakaicin ƙarfin fitarwa na lokaci na yanzu | 400VA | |
| Sa'o'in aiki da aka halatta @ max.fitarwa na 6-phase parallel current | 10s | |
| Daidaito | ≤0.5A ± 2mA >0.5A 0.2% | |
| Kewayon mitar (Tsarin igiyar ruwa) | 0 ~ 1000 Hz | |
| lokutan masu jituwa | 0 ~ sau 20 | |
| Fitowar DC na Yanzu | Fitowa na yanzu | 0 ~ ± 10A/lokaci;0 ~ ± 60A/6-pahse daidaici |
| Daidaito | 0.5% | |
| Matsakaicin ƙarfin ƙarfin fitarwa | 20V | |
| Wutar Lantarki AC | Fitowar wutar lantarki ta lokaci (RMS) | 0 ~ 120V Daidaitawa: 0.2% |
| Fitar wutar lantarki ta layi (RMS) | 0 ~ 240V | |
| Wutar lantarki na zamani/Layin ƙarfin fitarwa | 80V/100 | |
| Kewayon mitar (Tsarin igiyar ruwa) | 0 ~ 1000 Hz | |
| lokutan masu jituwa | 1-20 sau | |
| Wutar Lantarki na DC | Girman ƙarfin fitarwa na lokaci | 0 ~ ± 160V Daidaitawa: 0.5% |
| Layin ƙarfin fitarwa amplitude | 0 ~ 320V | |
| Wutar lantarki na zamani/Layin ƙarfin fitarwa | 70V/140 | |
| Binary | Shigar da binary | Tashoshi 10 |
| Sadarwa mara aiki | 1 ~ 20mA, 24V | |
| Yiwuwar samun damar lamba | "0": 0 ~+6V;"1": +11V ~ +250V | |
| Fitowar binary | 8 guda DC: 220V/0.2 A;AC: 220V/0.5 A | |
| Tsawon Lokacin Aunawa | 0.1ms~9999s Daidaitaccen Aunawa: <0.1mS | |
| Girma & Nauyi | 480*360*200mm³ 19kg | |
| A'a. | Suna | Bayani | Qty/Raka'a | Hoto |
| 1 | Babban Unit | GDJB-1200A | 1 saiti |
|
| 2 | Fuse | 2A | 4guda |
|
| 10 A | 4guda | |||
| 3 | Igiyar wutar lantarki |
| guda 1 |
|
| 4 | Gwada waya | 0.5mja, rawaya, kore, baki kowane guda 2) | guda 8 |
|
| 5 | Gwajin waya 4 core | Baki (ja, rawaya, kore, baki)- lebur | 2 guda |
|
| 6 | Gwajin waya 4 core | Baki (ja, rawaya, kore, baki)- madauwari | 2 guda |
|
| 7 | Gwada waya | blue | guda 1 |
|
| 8 | Gwada waya | (fararen kofi kowane yanki 1) | 2 guda | |
| 9 | Gwada waya | ja, kore, rawaya kowane yanki 1) | guda 3 | |
| 10 | Gwada waya | baki | 2 guda | |
| 11 | Sadarwawaya |
| guda 1 |
|
| 14 | Babban manne gwaji | (ja, rawaya, kore, baki kowane yanki 1) | guda 4 |
|
| 15 | Karamin matse gwaji | (rawaya, kore, kowane guda 4) | guda 8 | |
| 16 | Karamin matse gwaji | (ja, baki kowane guda 5) | guda 10 | |
| 17 | Misali | (ja, rawaya, kore, baki kowane guda 2) | guda 8 | |
| 18 | Gwajin allura | (ja, rawaya, kore, baki kowane guda 3) | guda 12 | |
| 19 | CD |
| 1 kwafi |
|
| 20 | QC wuce | A Turanci | 1 kwafi |
|
| 21 | Manual | A Turanci | 1 kwafi | ![]() |