GDOH-II Mai Gwajin Abun Gas Mai Insulating
GDOH-II Insulating Oil Gas Gwajin Abun Gas sabon ƙarni ne mai gwadawa da ke ɗaukar babban firikwensin inganci da aka shigo da shi da sabuwar fasahar firikwensin.Ya dogara ne akan ma'aunin masana'antar wutar lantarki na DL423-91 da ma'auni na ƙasa masu dacewa.Ya fi dacewa, mafi kwanciyar hankali kuma abin dogara a cikin aiki, mai sauƙi don aiki kuma ya fi dacewa don ƙayyade abubuwan da ke cikin gas a cikin kayan aiki mai cike da wutar lantarki mai girma.Yana da kyakkyawan kayan gwaji don dakin gwaje-gwaje.
●Tsarin duk-karfe yana guje wa matsalolin rashin ƙarfi da ƙarancin rufewa na gwajin gilashin gilashi.
●Aikace-aikacen babban madaidaici da kwanciyar hankali da aka shigo da firikwensin matsa lamba daban-daban yana sa bayanan gwajin ya zama daidai kuma mai maimaitawa.
●Da'irar gwaji ta ƙunshi na'urori masu auna firikwensin yanayi da zafin yanayi.Duk inda kuke, zaku iya auna yanayin yanayi ta atomatik da matsin yanayi a wurinku, ta atomatik juya zuwa abun cikin gas a 0° ƙarƙashin ma'aunin yanayin yanayi, kuma ku nuna shi kai tsaye akan allon LCD.
●Na musamman allurar iskar gas na gwajin daidaitaccen tsari yana ba ku damar bincika cikin sauƙi ko an daidaita kayan aikin ko auna daidai.
●Lokacin gwajin samfurin mai gajere ne, kuma duk lokacin gwajin yana ɗaukar kusan mintuna 7 kawai.
●A lokacin gwajin, ana sarrafa aikin injin famfo ta hanyar kayan aiki bisa ga jihar, wanda ke rage yawan hayaniya sosai kuma yana tsawaita rayuwar injin injin.
●Kayan aikin na iya adana bayanan gwajin dozin na ƙarshe ta atomatik, kuma ya adana lokacin gwajin, zafin jiki, matsa lamba na yanayi, da sauransu, ta yadda zaku iya bincika bayanan cikin sauƙi.
●Tare da aikin bugu, zaku iya buga bayanan gwaji gwargwadon buƙatun ku.
●Ana iya zaɓar samfurin mai guda ɗaya don adadin gwaje-gwaje.Bayan an gama gwajin, za a nuna sakamako guda ɗaya da matsakaita akan nuni ko buga.
Babban madaidaicin firikwensin bambancin matsa lamba na lantarki | Ƙimar ba ta ƙasa da 0.1%. | |
Iyakar ganowa mafi ƙarancin | Babu fiye da 0.2%. | |
Daidaito | Kuskuren dangi na sakamakon ma'aunin maimaitawa bai kamata ya wuce ƙimar masu zuwa ba: | |
Abubuwan da ke cikin iskar gas a cikin mai (ƙarar juzu'i),% | Kuskuren dangi,% | |
<0.5 | 10 | |
0.5 ~ 1.0 | 8 | |
1.0 ~ 3.0 | 5 | |
> 3.0 | 3 | |
Degassing dakin kula da zafin jiki kewayon | 5 ℃ zuwa 70 ℃ sama da zafin jiki | |
Wutar lantarki mai aiki | AC 220V± 10%, 50Hz | |
Girma | 450*325*350mm | |
Nauyi | Kimanin 20kg |
Mai gwadawa | 1 saiti |
Igiyar wutar lantarki | guda 1 |
Vacuum famfo & haši | 1 saiti |
3mm bakin karfe bututu | 1.5m, 0.5m |
Mai haɗa sirinji | 1 saiti |
Farashin 10A | guda 3 |
M8 × 1 kwaya | guda 10 |
Hatimi | guda 10 |
Bakin sirinji | guda 1 |
1 ml sirinji calibration | guda 1 |
Rotary vane injin famfo | 1 saiti |
Jagoran Jagora | 1 kwafi |
Takaddun shaida na samfur | 1 kwafi |
Rahoton gwajin masana'anta | 1 kwafi |
Jerin kaya | 1 kwafi |