GDPQ-300A Mai Binciken Ingancin Wutar Wuta
●Kayan aikin babban kayan gwaji ne na musamman da ake amfani da shi don gano matsalolin ingancin wutar lantarki kamar murdiya ta hanyar igiyar ruwa, abun ciki mai jituwa da rashin daidaituwa na matakai uku a cikin wutar lantarki.Hakanan yana da ayyuka na gwajin siga na lantarki da nazarin vector.
●Zai iya auna daidai ƙarfin lantarki, halin yanzu, ƙarfin aiki, ƙarfin amsawa, kusurwar lokaci, ma'aunin wutar lantarki, mita da sauran sigogin lantarki.
●Yana iya nuna zanen vector na ma'aunin ƙarfin lantarki da na yanzu.Mai amfani zai iya nazarin zanen vector don samun daidaiton wayoyi na kayan awo.
●Ana auna halin yanzu ta hanyar na'ura mai ɗaukar hoto.Mai aiki baya buƙatar cire haɗin madauki na yanzu lokacin aunawa tare da taswira na yanzu mai nau'in matsa, ana iya yin ma'aunin cikin dacewa da aminci.Za'a iya zaɓar jeri daban-daban na manne bisa ga kewayon ma'aunin mai amfani.
●Yana iya aunawa da bincika ingancin ƙarfin AC wanda grid mai amfani ke bayarwa ga abokin ciniki.Zai iya auna da kuma bincika: mambobin mita, karkacewa na ƙarfin hali, ƙarfin lantarki uku da ba shi da daidaituwa da grid tarbonics.
●Yana iya nuna irin ƙarfin lantarki na lokaci-lokaci da na yau da kullun kuma yana nuna ƙarfin lantarki mai mataki uku da na yanzu.
●Duk mu'amalar gwaji suna da aikin kulle allo don sauƙaƙe karatun mai amfani da nazarin bayanai.
●Kula da jujjuyawar lodi: Aunawa da nazarin jujjuyawar kayan aikin lantarki daban-daban waɗanda ke haifar da ingancin wutar lantarki na grid mai amfani a ƙarƙashin yanayin aiki daban-daban.Rubuce-rubucen lokaci da adana abubuwan da ke faruwa a cikin ƙarfin lantarki, halin yanzu, ƙarfin aiki, ƙarfin amsawa, bayyananniyar ƙarfi, mita, lokaci, da sauran sigogin wuta.
●Kulawa mai ƙarfi na daidaitawar kayan aikin wutar lantarki da tsarin aiki don taimakawa masu amfani da su warware matsaloli a cikin tsarin daidaita kayan aikin wutar lantarki da ƙaddamarwa.
●Ikon gwadawa da tantance ma'auni masu ƙarfi na ramuwar wutar lantarki da na'urori masu tacewa a cikin tsarin wutar lantarki da ƙididdige ƙimar ayyukansu da alamun fasaha.
●Zai iya saita lokacin tazarar ajiya daban-daban, ci gaba da adana bayanai gwargwadon tazarar lokacin da aka saita;
●Ginin da aka gina a cikin manyan ma'auni na bayanai, ana iya adana shi gaba daya fiye da watanni 18 a cikin tazara na minti 1, wanda zai iya biyan bukatun wuraren gwajin sa ido na dogon lokaci.
●Kayan aikin yana da kebul na USB, wanda ke iya kwafin bayanai cikin sauƙi kai tsaye zuwa kwamfutar sarrafa bayanan baya.
●A haɗe tare da software mai ƙarfi na sarrafa bayanai, ana iya loda samfuran da aka ƙirƙira na ainihin-lokaci kai tsaye zuwa kwamfutar sarrafa bayanan don ƙarin cikakkun bayanai da sauri a bango.
●Tare da kalandar dindindin, aikin agogo, ainihin lokacin nunin kwanan wata da lokaci.Ana iya adana bayanan gwaji da sakamako a lokaci guda, kuma a ɗora su zuwa kwamfuta ta hanyar tashar jiragen ruwa, ta hanyar software na sarrafa bayanan (na zaɓi) don cimma nasarar sarrafa micro-kwamfuta bayanai, tare da ƙarfin bayar da rahoto.
●Yana ɗaukar babban allo na LCD azaman nuni, ƙirar aiki na Ingilishi da ƙirar nunin LCD tare da saurin bayanin halayen Ingilishi da nunin sigina da yawa.Motar tattaunawa ta mutum da injin tana da abokantaka.
●Minti 3 babu aiki nuni LCD yana shiga ta atomatik yanayin ceton wuta, don haɓaka rayuwar baturi.
●Maɓallin silicone mai aiki, jin daɗi, tsawon rai, ƙira mai ma'ana, mai sauƙin aiki.
●Gina mai ƙarfi mai ƙarfi, babban aikin lithium-ion mai cajin baturi, na iya aiki sama da awanni 10 bayan caja cikakke.
●Ƙananan girman, nauyi mai sauƙi, mai sauƙin ɗauka, ana iya amfani dashi don aunawa a kan wurin, kuma za'a iya amfani da shi azaman kayan auna ma'aunin dakin gwaje-gwaje.
| Shigarwa | |
| Kewayon ma'aunin wutar lantarki | 0-200V-800V, mota smaita |
| Kewayon aunawa na yanzu | CT: 5A/25A (misali) 100A/500A (na zaɓi) 400A/2000A (na zaɓi) |
| Kewayon ma'aunin kusurwa na lokaci | 0 ~ 359.99° |
| Kewayon auna mitoci | 45 ~65 Hz |
| Tashar wutar lantarki | 3 tashar (UA, UB, UC) |
| Tashar ta yanzu | 3 tashar (IA, IB, IC) |
| Matsakaicin lokutan bincike masu jituwa | sau 63 |
| Matsakaicin ci gaba da ajiya na tazarar minti 1 | watanni 18 |
| Daidaito | |
| Sashin auna ma'aunin lantarki | |
| Wutar lantarki | ±0.2% |
| Yawanci | ± 0.01Hz |
| Yanzu, iko | ± 0.5% |
| Mataki | ± 0.2° |
| Bangaren ingancin wutar lantarki | |
| Kuskuren jurewar wutar lantarki na asali | ≤0.5% FS. |
| Babban kuskuren haƙuri na yanzu | ≤1% FS |
| Kuskuren auna bambancin lokaci tsakanin ainihin ƙarfin lantarki da na yanzu: | ≤0.2° |
| Kuskuren auna abun ciki mai jituwa irin ƙarfin lantarki | ≤0.1% |
| Kuskuren auna abun ciki na yanzu mai jituwa | ≤0.2% |
| Kuskuren rashin daidaiton wutar lantarki mai mataki uku: | ≤0.2% |
| Kuskuren karkatar da wutar lantarki | ≤0.2% |
| Kuskuren bambancin wutar lantarki | ≤0.2% |
| Yanayin aiki | -10 ℃ ~ +40 ℃ |
| Cajin iko | AC 220V, 45Hz-55Hz |
| masu amfani da wutar lantarki | Farashin 3VA |
| matsakaicin lokacin aiki na baturi | ≤10 hours |
| Insulation | (1) Juriya na insulation na ƙarfin lantarki da tashoshi na shigarwa na yanzu zuwa casing shine ≤100MΩ. (2) Ƙarshen shigar da wutar lantarki mai aiki yana ƙarƙashin mitar wutar lantarki na 1.5KV (ƙima mai inganci) tsakanin casings na waje, kuma yana ɗaukar minti 1 don gwadawa. |
| Girma | 320mm*240mm*130mm |
| Nauyi | 2.0kg |