GDYB-S6 Gwajin Mitar Makamashi Mataki Uku
6-matsayi Mita Gwajin Bench (Three Phase)
●Ƙirar ƙaƙƙarfan ƙira, ma'aunin mita na kayan gwaji da firam ɗin tebur duk an yi su ne da gami na musamman na aluminum kuma farantin fuskar tebur an yi shi da wuta da kayan fiber mai hana zafi.
●Sauƙi don amfani, duka keyboard da aikin PC suna samuwa.
●Nagartaccen aiki da kai.Mai amfani kawai yana buƙatar saka mita, daidaita samfurin photoelectric kuma saita sigogi a cikin yanayi mai kyau, sannan duk abubuwan gwaji, gami da dumama dumama, kunnawa da gwaje-gwajen kunnawa na ƙarya, daidaitaccen gwajin karkata, gwajin kuskure na asali ana sarrafa ta PC ta ɗaya. gwadawa.Hanyar daidaita mitoci za a iya ayyana mai amfani.
●Photoelectric sampler iya gane uku-girma daidaitawa.Ba wai kawai zai iya misalta siginar faranti na mitar jujjuya ba amma kuma tana karɓar siginar strobe na mitar lantarki.
●Tsarin sarrafa kuskure zai iya karɓar sigina daga samfurin photoelectric da bugun jini na fitarwa na nau'in nau'in nau'in lantarki na sakawa, da siginar bugun jini mai girma na daidaitattun mita.
●Mita iri ɗaya (layin lokaci ɗaya, ƙarfin lantarki mai ƙima, ƙayyadaddun halin yanzu) amma mabanbanta daban-daban (a galibi nau'ikan 3) ana iya gwada su a lokaci guda.
●Gwaji aikin sadarwa na RS485 na mita masu aiki da yawa, kuskuren da ake buƙata kuma kuskuren agogo zaɓi ne (Fitowar siginar lokaci ya zama dole).
●Nemo wurin alamar jujjuya mita ta atomatik, wanda ke ba da sauƙin gwajin kunnawa na karya.
●Ƙarfafa 2 zuwa 21 masu jituwa a cikin mahimmancin igiyar wutar lantarki, girman jituwa da lokaci ana iya saita su gwargwadon buƙatun.Hakanan ana iya yin nazari na jituwa da zanen igiyar ruwa don abubuwan fitarwa.
●Gwajin atomatik akan kowace naúrar ƙarfin lantarki, halin yanzu, ƙarfin wuta da jimlar ƙarfin lokaci guda uku.
●Babban kwanciyar hankali da aminci, wanda zai iya samar da ƙarfin fitarwa mai ƙarfi.Wutar lantarki (na yanzu) madauki na iya ɗaukar nauyin kowane nau'i.
●Ana samar da kayan gwajin tare da cikakken aikin dubawa, ganowa, karewa da ayyuka masu ban tsoro don guje wa lalacewar benci sakamakon kuskuren wayar hannu ko aiki.
●Software na PC yana ba da cikakkun ayyuka, kamar buga rahoton, ƙididdige adadin da kiyaye kadarorin
●Matsayin daidaito: 0.05%
●Wutar lantarki mai fitarwa: 3*100V/57.7VY 3*100V ∆
3*380V/220V 3*380V ∆
Kewayon sarrafawa: 0-120% daidaitacce a jere
Daidaita daidaito: mafi kyau fiye da 0.01%
* Ana iya saita kewayon wutar lantarki na musamman bisa ga ainihin tsari.
●Kewayon yanzu: 0.1A, 0.25A, 0.5A, 1A, 2.5A, 5A, 10A, 20A, 50A, 100A
Kewayon sarrafawa: 0-120% daidaitacce a jere
Daidaita daidaito: mafi kyau fiye da 0.01%
●Ƙarfin fitarwa: (madauki na lantarki) GDYB-S6 100VA
(Madauki na yanzu) GDYB-S6 150VA
●Ƙarfafa ƙarfin fitarwa, halin yanzu da ƙarfi:
≤0.02%/120S PF=1 (Class 0.05)
≤0.05%/120S PF=1 (Class 0.1)
●Karɓar igiyoyin wutar lantarki da na yanzu: ≤0.5%
●Alamar lokaci uku: mafi kyau fiye da 120°+0.3°
●Kewayon mitar: 45Hz-65Hz daidaita daidaito: 0.01 Hz
●Kewayon jujjuya lokaci: -180.0°-180.0° daidaita daidaito: 0.1°
●Daidaitaccen kwanciyar hankali na oscillator crystal: ≤10-7/s
●Matsayin kayan aiki
Voltmeter da ammeter daidaito: matakin ± 0.2%
Daidaitaccen mita mataki: ± 0.5°
Daidaiton mitar mitar: ± 0.01Hz
●Matsakaicin mita don gwaji: 6
●Ƙarfin wutar lantarki: 3 * 220V± 10%, 50Hz (ko 120V± 10%, 60Hz)
●Matsakaicin amfani da wutar lantarki: 1500VA
●Yanayin aiki: 20± 5℃ dangi zafi: ≤85%
●Girma da nauyi:
2000mm*720mm*1550mm 280Kg