GDYZ-301 Zinc Oxide Surge Arrester Gwajin
1. 800*480 launi LCD tabawa, tare da babban gudun thermal printer.
2. Nuni mai hoto, ƙirar ƙira, mai sauƙin aiki da amfani akan rukunin yanar gizon.
3. Watsawa mara waya ta nesa mai nisa.Nisan watsa siginar mara waya ta PT fiye da 400m (ana iya daidaita 2000m).
4. Ya dace da gwaji a yanayi daban-daban kamar mai kama walƙiya tare da ko babu wutar lantarki, dakin gwaje-gwaje.
5. Gwada uku lokaci halin yanzu, uku lokaci ƙarfin lantarki a lokaci guda, mafi inganci.
6. Babu wutar lantarki mai ƙarfi a ciki, ƙarfin lantarki bai wuce 12V ba.Na'urori masu auna firikwensin na yanzu da na lantarki gaba ɗaya sun keɓe, amintattu kuma abin dogaro.
7. Tallafi daban-daban samfurin irin ƙarfin lantarki: 1. Waya;2 mara waya;3. Rashin wutar lantarki;
A. Waya: watsa siginar dijital tare da kebul wanda siginar ta fito ne daga PT metering winding;
B. Mara waya: dijital sigina watsa mara waya wanda siginar daga PT metering winding;
C. Rashin wutar lantarki: babu buƙatar samun sigina daga tashoshin PT.Yi amfani da lissafin software don samun ma'aunin wutar lantarki.
8. Batir Li-batir ɗin da aka gina a ciki, wanda ya dace da babu filin samar da wutar lantarki.
9. Yana ɗaukar dandamali na kayan masarufi da tsarin aiki, yana iya fadada ayyukan sake kunna sauti da bidiyo da ayyukan nishaɗin wasa.
10. Ana iya kunna kayan aiki da kashewa a kowane lokaci, wanda ya fi kwanciyar hankali fiye da na'urar da ke da kwamfutar masana'antu a matsayin dandamali na kayan aiki, kuma ba shi da sauƙin faɗuwa da rushewar tsarin.
11. An sanye shi da tashar USB don tallafawa fitar da bayanai daga U disk.
12. Katin SD na 4GB da aka gina a ciki, yana iya adana manyan bayanan gwaji, kuma yana da ayyuka kamar sarrafa bayanai da adanawa.
13. Babban saurin samfurin mita, ci-gaba da fasahar sarrafa siginar dijital, aikin hana tsangwama mai ƙarfi, sakamakon ma'auni mai mahimmanci.
14. Tare da ƙurar ƙura, mai hana ruwa, ƙwayar filastik filastik da aka rufe akwatin, ƙananan ƙananan, nauyin nauyi, mai sauƙin ɗauka.
1. Samar da Wutar Lantarki
Goyan bayan adaftar wutar lantarki ta waje (12V/2A) da yanayin samar da wutar lantarki na ciki;
2. Ma'auni
Leakage Current (RMS) 0-10mA (mai daidaitawa);
Wutar lantarki (RMS) 30-100V (mai iya daidaitawa).
3. Auna daidaito
Yanzu: jimlar halin yanzu> 100μA, ± 2% na karatun ± 1 lambobi;
Ƙarfin wutar lantarki: Siginar wutar lantarki Reference> 30V
Waya: ± 2% na karatun ± 1 lambobi;
Mara waya: ± 5% na karatun ± 1 lambobi;
4. Ma'aunin ma'auni
Leakage na halin yanzu jimillar sigar kalaman na yanzu, RMS na asali, ƙimar kololuwa.
Abubuwan juriya na asali na RMS na ɗigogi na yanzu, 3, 5, 7 sau RMS.
Ƙimar ƙoƙon ɓangaren juriya na halin yanzu, gami da ingantaccen ƙimar Ir+, ƙimar kololuwar ƙimar Ir-.
Capacitive halin yanzu muhimmi kalaman, jimlar ƙarfin lantarki, cikakken halin yanzu bambancin kwana na yanzu.
Wutar lantarki RMS.
Amfanin wutar lantarki na kama.
5. Hanyar samfurin siginar wutar lantarki na nuni
Aiki tare da waya: 20m (ana iya tsawaita);
Aiki tare mara waya:>400m (ana iya tsawaita);
6. Sigar baturi
Lokacin caji> 6 hours
Ci gaba da aiki lokaci> 4 hours
Lokacin aiki na wucin gadi> 8 hours
7. Girma:360 * 260 * 140mm (Mai watsa shiri);420 * 330 * 200mm (Kayan haɗi);
8. Nauyi:5kg (Mai watsa shiri);9kg (Kayan haɗi);
Hoto 1 Kwamitin Mai watsa shiri
1. Grounding tashar jiragen ruwa 2. 0-2mA halin yanzu shigarwa 3. 2-10mA halin yanzu shigarwa
4. Eriya tsotsa 5. Wireless tashar jiragen ruwa aiki tare 6. Waya aiki tashar jiragen ruwa
7. Maɓallin ON / KASHE 8. Cajin tashar jiragen ruwa 9. Alamar sigina
10. Alamar wuta 11. Fan 12. USB interface 13. Tabawa LCD allon taɓawa 14.Printer
Hoto 2 PT Voltage Emitter
1. Maɓallin ON / KASHE 2. Cajin tashar jiragen ruwa 3. Alamar wuta
4. Antenna tsotsa 5. Alamar sigina 6. tashar tashar eriya
7. Ƙaddamar da ƙasa 8. Tashar sadarwa tsakanin mai watsa shiri da PT ƙarfin lantarki emitter 9. PT ƙarfin lantarki shigar
Mai watsa shiri | 1pc |
Kayan haɗi | 1pc |
PT wutar lantarki emitter | 1pc |
Kebul na gwaji na yanzu | 3pcs |
Kebul na gwajin wutar lantarki | 1pc |
Kebul na ƙasa | 2pcs |
Sadarwana USB | 1pc |
Eriya | 2pcs |
Caja | 2pcs |
Takarda bugu | 2 rolls |
Mai amfani'smshekara-shekara | 1pc |
Rahoton gwaji | 1pc |