Kayan aiki ne na musamman na gwada aikin lantarki na zinc oxide.Kayan aiki na iya auna daidai da daidaitaccen ma'auni mai jujjuyawa na halin yanzu da na'urori masu saka idanu yayin da kayan aiki ke gudana.Hakanan yana iya duba ammeter na duba.
●8inch launi LCD tabawa, babban saurin thermal printer.
●Bayanan ma'auni na waya da mara waya iri ɗaya ne.
●Samfurin mara waya, tare da nisa mai nisa.
A. Waya: amfani na cikin gida, ko a wurin da PT Samfur majalisar wayoyi ke kusa tare da gwajin kama walƙiya.
B. Wireless: amfani da waje, ko a wurin da PT Samfurin wiring cabinet yayi nisa da gwajin kama walƙiya, nisa mara waya ya kai 1000M.
●Ana iya auna matakai uku a lokaci guda.Ana iya auna ƙarfin halin yanzu na 3channels a lokaci guda, a halin yanzu, akwai hanyoyi guda biyu na hana tsangwama: 1) babu tsangwama: kusurwar tsaka-tsakin ba za a iya ƙididdige shi ba kuma gyara ta atomatik a ƙarƙashin wannan yanayin;2) Tare da tsangwama: za'a iya ƙididdige kusurwar tsaka-tsakin tsaka-tsakin da kuma gyara.Haɗin lokaci ɗaya kawai don gama ma'aunin lokacin ABC.
●Batir Li-batir ɗin da aka gina a ciki, wanda ya dace da babu filin samar da wutar lantarki.
| Usai hali | -20 ℃ - 50 ℃ | RH<80% |
| Charging samar da wutar lantarki | AC 220V± 10% | |
| Kewayon shigarwa na PT tunani irin ƙarfin lantarki | 0-300V | |
| Input juriya na tashar wutar lantarki | ≥150kΩ(wfuse) | |
| Auna daidaito na PT tunani irin ƙarfin lantarki | ±(2% na karatun +0.5V) | |
| Msauƙaƙe kewayon shigarwa na yanzu | 0-10mA ku | |
| Mtabbatar da daidaito na asali na yanzu | ±(2% na karatun+5μA) | |
| Mtabbatar da daidaiton jituwa na yanzu | ±(5% na karatun+10μA) | |
| Input juriya na halin yanzu tashar | ≤1Ω | |
| Action sau na saka idanu | 0 zuwa 99times | |
| 8 / 20 μS motsi halin yanzu | ≥50Ap | |
| Calibration kewayon mita na yanzu | 0-10mA ku | |
| Cdaidaitaccen alibration na mita na yanzu | ±(2% na karatun+5μA) | |
| Mƙudurin kwanciyar hankali | Voltage | 0.001V |
| Cgaggawa | 0.001mA | |
| Akwana | 0.001° | |
| Blokaci mai aiki | Mina unit 8hnamu, akwatin samfurin wutar lantarki 12hours | |
| Wnisa watsawa mara amfani | Mita 1000 da sama (ba komai kumauba a rufe) | |
| Dimension na main unit | 320×270×140mm | |
| Hbinciken tarin da aka gudanar | 180×120×80mm | |
| Nauyin babban naúrar | 4kg (ba tare da kayan haɗi ba) | |
| Mina unit | 1pice |
| Sampling naúrar | 1pice |
| Wnaúrar sadarwa mara waya | 1pice |
| Measurement USB na 3-phase resistive halin yanzu | 1pice |
| Sampling na USB na 3-phase ƙarfin lantarki | 1pice |
| Output na USB na daidaitawar mita na yanzu | 1pice |
| Gzagaye na USB | 1pice |
| Ƙarfiigiya | 1pice |
| Charger | 1pice |
| Famfani | 3pcs |
| Print takarda | 1roll |
| Alligator Clip | 8pcs |
| Rahoton gwaji | 1 guda |
| Mai amfani's jagora | 1 guda |