Tsare-tsare don Tsarin Gwajin Resonance Series
Tsare-tsare don Tsarin Gwajin Resonance Series 1. A lokacin gwajin, ana haɗa lokacin gwajin zuwa babban tushen wutar lantarki, kuma babbar waya mai ƙarfin lantarki tana buƙatar amfani da waya na gubar mara nauyi ta musamman, kuma lokacin mara gwajin yana ƙasa. tare da harsashi GIS;2. Dole ne gwajin ya tabbatar da cewa SF6 gas a cikin ea ...Kara karantawa -
Yadda za a hana matsalolin wuce gona da iri yadda ya kamata yayin aikin tashar
A yayin da ake gudanar da aikin na’urar taransifomar da ba ta da kaya, za a yi wani abu na zahiri da ba za a iya kaucewa ba, wato yankewa.Ana iya kare matsalar yawan aiki da wutar lantarki ta hanyar yanke na'urar da za a iya magance ta ta hanyar ɗaukar matakai kamar haka: 1. Inganta ƙarfin ƙarfe na haɓaka ƙarfe co...Kara karantawa -
Yadda za a auna asarar dielectric na transformer
Da farko, zamu iya fahimtar cewa asarar dielectric shine cewa dielectric yana ƙarƙashin aikin filin lantarki.Saboda dumama na ciki, zai canza wutar lantarki zuwa makamashin zafi kuma ya cinye shi.Wannan bangare na makamashin da ake amfani da shi ana kiransa asarar dielectric.Rashin wutar lantarki...Kara karantawa -
Bambanci tsakanin na'urar gwajin ƙarfin wutar lantarki na DC da na'urar gwajin ƙarfin ƙarfin AC
1. Daban-daban a cikin yanayi AC tsayayyar na'urar gwajin wutar lantarki: hanya mafi inganci da kai tsaye don gano ƙarfin rufewa na kayan lantarki.Na'urar gwajin ƙarfin wutar lantarki ta DC: don gano ƙaramin ƙarfin ƙarfin ƙarfin da kayan aikin ke jurewa a ƙarƙashin babban gwajin ƙarfin lantarki.2. Da...Kara karantawa -
Wadanne abubuwa ne ke shafar sakamakon gwajin resonance jerin?
Ko da tare da abin da ake kira "dukkan mai iko" jerin resonance, sakamakon gwajin zai ci gaba da shafar abubuwan da ba su da tabbas, ciki har da: 1. Tasirin yanayi A yanayin zafi mai zafi, asarar corona na wayar gubar yana ƙaruwa sosai. da kuma katsalandan na kewaye da zaɓaɓɓu ...Kara karantawa -
Yadda za a kula da na'urar gwaji ta busassun?
Nau'in gwaji na busassun na'ura sun dogara da kayan aikin sanyaya iska.Sabili da haka, yana da kyakkyawan aikin watsar da zafi da ingantaccen amfani da muhalli.Don haka, gabaɗaya, ana shigar da masu canjin busassun nau'in transfoma a kowane lungu na rayuwar mutane tare da nasu na musamman na advan...Kara karantawa -
Menene farkon janareta na yanzu da ake amfani dashi?
Babban janareta na yanzu shine kayan aikin da ake buƙata don wutar lantarki da masana'antar lantarki waɗanda ke buƙatar na yanzu na farko yayin ƙaddamarwa.Na'urar tana da halayen dacewa da amfani da kulawa, ingantaccen aiki, aminci da ingantaccen amfani, kyakkyawan bayyanar da stru ...Kara karantawa -
Amfani da Precations don Insulation mai Tan Delta Tester
Matsakaicin man da ba a tace ba ana kiransa mai, wanda ya ƙunshi ruwa da ƙazanta da yawa, kuma ƙarfin wutar lantarki ya fi ƙasa da 12KV.Musamman ga mai maras inganci tare da ruwa mai yawa, wasu masu amfani suna amfani da na'urar gwajin ƙarfin lantarki mai ƙarfi don gwada shi don sanin munin sa ...Kara karantawa -
Hanyoyi daban-daban na wayoyi na gwajin juriya na duniya
Hanyoyin ma'auni na ma'aunin juriya na ƙasa yawanci suna da nau'o'i masu zuwa: hanyar waya biyu, hanyar waya uku, hanyar waya hudu, hanyar matsewa guda ɗaya da kuma hanyar matsewa sau biyu, kowanne yana da nasa halaye.A ainihin ma'auni, gwada zaɓar hanyar da ta dace don yin ma'aunin ...Kara karantawa -
Lissafi na jerin resonance jure gwajin ƙarfin lantarki
Jarrabawar jurewar wutar lantarki hanya ce ta gwaji da ake amfani da ita don gwada ƙarfin tsarin tasoshin matsi.Abubuwan da za a yi la'akari da su a cikin tsarin lissafin su ne: Ma'auni na geometric na akwati: ciki har da siffar, girman, kauri, da dai sauransu na akwati.Material phy...Kara karantawa -
Wadanne matsaloli ya kamata a kula da su wajen auna ma'aunin ma'aunin polarization
Sharuɗɗa don auna ma'auni na sha Ba za a iya auna rabon sha da ƙididdiga na polarization na taswira tare da ajin ƙarfin lantarki na 10kv da ƙarfin rarraba hanyar sadarwa da ke ƙasa da 4000kvA ba.Lokacin da ƙarfin wutar lantarki ya kai 220kv ko sama da capa ...Kara karantawa -
Waɗanne gwaje-gwaje ya kamata a yi kafin da kuma bayan na'urar kashe wutar lantarki?
An kasu kashi-kashi zuwa na'urorin da'irar mai, na'urorin da'irar iska, sulfur hexafluoride circuit breakers da vacuum circuit breakers bisa ga nau'in matsakaici.Mu duba abubuwan gwajin wutar lantarki da za a yi kafin da kuma bayan an yi wa na'urar gyaran fuska.Gwaji...Kara karantawa