  • Menene matakan kariya don amfani da na'urar dawo da iskar gas SF6?

    Menene matakan kariya don amfani da na'urar dawo da iskar gas SF6?

    Idan kun san wani abu game da na'urar dawo da iskar gas na SF6, kowa ya kamata ya san cewa na'urar tana da ayyuka na yau da kullun kamar ɓarna, farfadowa da adanawa, cikawa da fitarwa, cika kwalban da tsarkakewa da bushewa, da kuma daidaitattun ayyukan haɗin gwiwa.Idan dai kayan aikin da kuke…
    Kara karantawa
  • Laifi da hanyoyin dubawa a cikin aiki na tsarin kariya na gudun ba da sanda

    Hanya mafi rauni a cikin tsarin kariyar relay ita ce taswira a cikin wutar lantarki tsarin wutar lantarki.A cikin madauki na ƙarfin lantarki, yana da sauƙi don rashin aiki yayin aiki.Mai canzawa a cikin wutar lantarki yana taka muhimmiyar rawa a cikin aiki na yau da kullun na tsarin wutar lantarki.Aiki, kodayake babu ...
    Kara karantawa
  • Jagoran kulawa don masu canzawa irin na gas

    Jagoran kulawa don masu canzawa irin na gas

    Na'urorin gwajin gwaji sune kayan gwaji masu mahimmanci don gwajin kayan wuta da gwaje-gwaje na rigakafi.Tare da haɓaka masana'antar samar da wutar lantarki ta ƙasata, abubuwan da ake buƙata don matakin ƙarfin lantarki na na'urorin gwaji suna ƙaruwa da haɓaka.Koyaya, na'urorin gwaji na gargajiya da aka nutsar da mai sune ...
    Kara karantawa
  • Yadda ake kula da na'urar gwaji ta Dry-type

    Yadda ake kula da na'urar gwaji ta Dry-type

    Nau'in gwaji na busassun na'ura sun dogara da kayan aikin sanyaya iska.Sabili da haka, yana da kyakkyawan aikin watsar da zafi da ingantaccen amfani da muhalli.Sauƙaƙan na'urorin canza launin busassun ana shigar dasu cikin kowane lungu na rayuwar mutane tare da fa'idodi na musamman.Don haka, yaya kuke...
    Kara karantawa
  • Yadda za a hana walƙiya ya tashi don manyan layukan lantarki?

    Yadda za a hana walƙiya ya tashi don manyan layukan lantarki?

    Gabaɗaya, duk layin layin UHV ana kiyaye shi ta hanyar waya ta ƙasa, ko wayar ƙasa da kebul na gani na OPGW, wanda ke da wasu tasirin kariya ta walƙiya don layin watsa UHV.Takamaiman matakan kariya na walƙiya sune kamar haka: GDCR2000G Gwajin Juriya na Duniya 1. Rage th ...
    Kara karantawa
  • Ƙwarewar siyan Generator na yanzu na Farko

    Ƙwarewar siyan Generator na yanzu na Farko

    Lokacin da kuke buƙatar haɓaka kayan aikin wutar lantarki mai ƙarfi, kuna buƙatar amfani da janareta na farko-na yanzu.Kayan aiki ne masu mahimmanci don kowane nau'in rayuwa a cikin lalata lantarki inda ake buƙatar farko-na yanzu.Ayyukan maɓallin taɓawa, duk ayyuka ana iya yin su ta hanyar maɓalli Inganta aminci da r ...
    Kara karantawa
  • Lokacin da ake buƙatar amfani da Series Resonance AC Tsarewar Gwajin Wuta

    Lokacin da ake buƙatar amfani da Series Resonance AC Tsarewar Gwajin Wuta

    Akwai da yawa jerin resonance AC jure irin ƙarfin lantarki da aka saita a kasuwa, waɗanda ma'aikatan wutar lantarki ke amfani da su don aikin gwajin ƙarfin wutar lantarki mai ƙarfi.Series resonance AC jure irin ƙarfin lantarki gwajin yana da matukar muhimmanci, don haka a karkashin abin da yanayi dole ne a yi amfani da jerin resonance AC tare da ...
    Kara karantawa
  • Hankali ga amfani da GD 6800 Capacitance & Tan Delta Tester

    Hankali ga amfani da GD 6800 Capacitance & Tan Delta Tester

    Masu wutar lantarki waɗanda ke son gudanar da gwaje-gwajen asarar wutar lantarki akan wutar lantarki, relays, capacitors, masu kamawa, da sauransu suna buƙatar amfani da na'urar gwajin hasarar dielectric mai hana tsangwama.A matsayin kayan aikin gwajin wutar lantarki na yau da kullun na yau da kullun, wannan kayan aikin yana da matakan ƙarfin lantarki da ingantaccen abin dogaro....
    Kara karantawa
  • Me yasa amfani da Saitin Gwajin Injection na Farko na Yanzu don auna juriyar mai watsewar da'ira?

    Ƙarfin lodin Saitin Gwajin Injection na Farko na Yanzu ya dace da kariyar busbar da tabbatar da ma'auni na canji na yanzu, da dai sauransu, kuma yana iya daidaita relays na yanzu da masu sauyawa.Ana amfani da shi musamman don gwada abubuwa kamar kariya ta busbar da curre daban-daban ...
    Kara karantawa
  • Kariyar aiki na AC RESONANT TEST SYSTEM

    1. Kafin amfani da AC RESONANT TEST SYSTEM don gwajin juriya.Da fatan za a auna juriyar rufin samfurin bisa ga tsarin gwajin kuma tabbatar da cewa samfurin ya cika buƙatun rufin da suka dace kafin ci gaba zuwa mataki na gaba na ...
    Kara karantawa
  • A taƙaice bayyana transformer CT

    Ana amfani da Transformer CT/PT Analyzer don gwaji ta atomatik na kariya da metering CT/PT.Ya dace da dakin gwaje-gwaje da gwaje-gwaje a kan wurin.Amma akwai kuma abokai waɗanda ba su yi hulɗa da wannan kayan aiki ba, don wasu ayyuka na yau da kullun, irin su wiring, panel controls ba su saba ba.
    Kara karantawa