Gabatarwar Aiki don Capacitance & Tan Delta Tester

Gabatarwar Aiki don Capacitance & Tan Delta Tester

Bayanin Capacitance & Tan Delta Tester

capacitance & tan delta tester wata hanya ce ta asali a cikin gwajin rufewa, wanda zai iya bincika yadda ya kamata gabaɗayan tabarbarewar damshin kayan aikin lantarki, da lahani na gida.Mitar mitar atomatik daban-daban & tan delta tester babban kayan gwaji ne mai girman gaske wanda HV Hipot ya haɓaka.Ana amfani da shi ne musamman don auna capacitance & tan delta tangent da capacitance na kayan aikin wutar lantarki daban-daban a cikin tashoshin wutar lantarki, tashoshin da sauran filayen ko a cikin dakunan gwaje-gwaje.Mita daban-daban ƙarfin ƙarfin atomatik & tan delta tester na iya gano yadda ya kamata gabaɗayan lalacewar danshi da lahani na gida na rufin kayan aikin lantarki.Ana amfani dashi ko'ina a cikin ma'aunin capacitance & tan delta na masu canji, masu canzawa, igiyoyin wuta da sauran kayan aiki a cikin masana'antar wutar lantarki.

                                                          异频全自动介质损耗测试仪

                                                                                                     GD6800 capacitance & tan delta tester

Aikace-aikacen capacitance & tan delta tester

capacitance & tan delta ana amfani dashi sosai a masana'antar lantarki, shigar da kayan aikin lantarki, mikawa da gwajin rigakafi.Har ila yau, kayan aikin ya dace don auna tgδ da ƙarfin ƙarfin lantarki na kayan aiki na lantarki a cikin bita, dakunan gwaje-gwaje da sassan binciken kimiyya;za a iya amfani da shi don gwada capacitance & tan delta na insulating mai a lokacin da aka sanye take da insulating mai kofuna.

Halayen capacitance & tan delta tester

Kayan aiki shine tsarin da aka haɗa tare da ginannen madaidaicin ma'auni da haɓaka samar da wutar lantarki, ƙananan girman, nauyi mai sauƙi, sauƙi don ɗauka, aiki mai sauƙi, ma'auni na atomatik, karatu mai hankali, babu juyawa, babban madaidaici, da ƙarfin hana tsangwama.

Tsarin capacitance & tan delta tester

Na'urar tana sanye da na'ura mai ɗaukar nauyi mai ƙarfi, kuma ta ɗauki matakan kariya kamar rufewar sifili da kariya ta walƙiya.A lokacin gwajin, kai tsaye ƙara 220V AC samar da wutar lantarki, na iya fitar da 2KV, 5KV, 10KV matakan daban-daban na babban ƙarfin lantarki, aikin yana da sauƙi kuma mai lafiya.

Aikin capacitance &tan delta tester

Wannan kayan aiki shine babban madaidaicin kayan aiki don aunawa ta atomatik na capacitance & tan delta na kayan aikin wutar lantarki daban-daban a cikin tashoshin wutar lantarki, tashoshin wutar lantarki da sauran filayen, kuma yana iya tabbatar da ma'auni daidai a ƙarƙashin tsangwama mai karfi na lantarki.Kayan aiki ya kara aikin menu na kasar Sin, aikin ya fi sauƙi kuma ya fi dacewa.Aiki ɗaya, microcomputer ta atomatik yana kammala duk aikin aunawa.Yana da manufa capacitance & tan delta auna kayan aiki.

Hanyar auna capacitance & tan delta tester

Ana iya auna na'urorin lantarki masu ƙarfin lantarki waɗanda ba su da ƙasa ko ƙasa kai tsaye ta hanyar hanyoyin sadarwa na gaba da baya.